Notes:

Press           to insert a 3.5 second pause in the

dialing sequence.

Press

to move the cursor left.

Press

to move the cursor right.

Press

to delete the character under the

cursor.

Press and hold

to erase the entire phone

number.

After programming all required phone numbers press       

to return to the top level Voice Dialler menu.

Alarm Message Play Time

This is the total time for which the alarm messages will

be played & repeated when a call made by the voice

dialler is answered.

Default setting:  70 seconds

Scroll through the menu until 

‘4-2 Message Play Time’

is displayed.  The current settings will also be displayed.

To change the settings press            .

Scroll through the available options, (50s, 70s, 90s

and 110s) until the required setting is displayed.

Press            to save and exit, or

Press            to exit without saving.

Record Alarm Messages

Scroll through the menu until 

‘4-3 RECORD VOICE’

is

displayed and press            .

Scroll  through  the  available  menu  options  until  the

required message type to be recorded is displayed.

a)  Main Alarm message, (12 seconds max).

b)  Intruder Alarm message, (4 seconds max).

c)  Fire Alarm message, (4 seconds max).

d)  Panic/PA Alarm message, (4 seconds max).

To record a new message press           .

Press              to  start  the  voice  recorder.    Once

completed  the  recording  will  automatically  be

replayed, or

Press             to exit without changing.

Note:  

After recording the message, press

to  stop  the  recorder  and  cancel  any  remaining

message time.

Press           to return to the top level Voice Dialler

setup menu.

Replay Alarm Messages

Scroll  through  the  menu  until 

‘4-4  REPLAY  ALARM

MESSAGES’ 

is displayed and press            .

Scroll  through  the  available  menu  options  until  the

required message type is displayed.

a)  Main + Intruder Messages

b)  Main + Fire Messages

c)  Main + Panic/PA Messages

To replay the message press            .

Press               to return to the top level Voice Dialler menu.

Call Routing

This  feature  controls  which  telephone  numbers  are

enabled in the dialing sequence and are dialed when

the voice dialler is activated.

The current routing sequence is displayed on screen

in the order of phone numbers 1- 4.  An "X" indicates

the  number  is  disabled  and  a  ‘O’  indicates  the

number is enabled in the routing sequence.  e.g.  A

display  =  "OOOx"  indicates  a  call  sequence  of

phone nos. 1, 2 and 3, phone number 4 is disabled

and not called.

Default setting:  all numbers disabled.

Scroll through the menu until 

‘4-5 CALL ROUTING’

is

displayed.  The current settings will also be displayed.

Scroll  through  the  available  menu  options  until  the

required  telephone  number  (1-4)  to  be  configured  is

displayed.  The current status will also be displayed.

To change the setting press            .

Press            to enable the number in the routing

sequence, or

Press            to disable the number in the routing

sequence.

Press                  to  return  to  the  top  level  Voice  Dialler

Setup menu.

29

ESC

ESC

ESC

ESC

ESC

ESC

1

3

1

3

Summary of Contents for SA5 E

Page 1: ...SA5 E 36 Zone Wirefree Alarm System with Voice Dialler Installation and Operating Instructions 1 2 3 4 5 6 8 7 0 9 ESC POWER ALARM STATUS ALARM MEMORY TEL MESSAGE LINE STATUS...

Page 2: ...etectors 14 Testing the Magnetic Contact Detectors 15 External Solar Siren 15 Positioning the Solar Siren 16 Installing the Solar Siren 16 Setting the Solar Siren 16 Initial Power Up of the Solar Sire...

Page 3: ...and External Solar Siren x 2 9V PP3 Alkaline battery for PIR Movement Detectors x 5 3V CR2032 Lithium cells for Remote Control and Magnetic Contact Detectors Important Please check all items listed a...

Page 4: ...zone is triggered an entry will be recorded in the Event Log but an alarm will not occur In addition there is the facility to connect 4 hard wired zones to the Control Panel each of which is fully co...

Page 5: ...of the Chime function would be to warn that a door or particular area has been accessed Voice Dialler If the Voice Dialler is enabled and an alarm condition occurs the system will call for help using...

Page 6: ...Solar Siren operate independently The Jamming Detection circuit is designed to permanently scan for jamming signals However it is possible that it may detect other local radio interference operating...

Page 7: ...ments and plan your installation The alarm system may be extended at any time to provide even greater protection by fitting additional devices to meet your personal security needs Planning and Extendi...

Page 8: ...thin reach of a mains socket 6 If the telephone voice dialler is to be used then the Control Panel will need connecting to a convenient telephone point Note It is recommended that the telephone connec...

Page 9: ...the batteries as connecting incorrectly could damage the batteries or the Control Panel Note The Power LED may flash to indicate that the unit is being operated from the back up batteries and that ma...

Page 10: ...urn as each button is pressed the Control Panel will beep and show the button being pressed on the display 4 Test the range of the Remote Control by pressing the DISARM button on the Remote Control fr...

Page 11: ...mounted within effective radio range of the Control Panel The PIR Detector is powered by a PP3 Alkaline battery which under normal conditions will have an expected life in excess of 1 year When the b...

Page 12: ...the rear cover and then slide down to release the top clips 2 Carefully drill out the required mounting holes in the rear cover using a 3mm drill according to whether the unit is being mounted in a co...

Page 13: ...up or down ensuring that the location legs are aligned with the required position number marked on the board 11 Refit the PIR Detector to the rear cover by offering the PIR Detector up to the rear cov...

Page 14: ...r the double sided adhesive tape or screws provided When fixing the Magnetic Contact Detector with screws the top of the Detector is secured with a keyhole slot over the screw head of the smaller pan...

Page 15: ...for will be displayed Note In normal mode with the battery cover fitted the LED on the detector will not illuminate when the detector is triggered unless the battery is low 4 If connected operate the...

Page 16: ...ternal or internal metalwork i e drainpipes gutters radiators mirrors etc Ensure that the position selected for the Solar Siren is within effective range of the Control Panel refer to Testing the Cont...

Page 17: ...le to disable the beeps if required by removing the jumper link P2 on the circuit board Siren Disable If for any reason you need to disable the Siren remove jumper link P3 on the circuit board This wi...

Page 18: ...power jack and disconnect one of the back up batteries Hardwired zone and tamper switches should be Volt free and Normally Closed with the contacts opening in order to initiate an alarm Note Jumper l...

Page 19: ...5 seconds Select Wirefree Siren Test to operate the External Solar Siren Select Hardwired Siren Test to operate the Control Panel Siren and external hardwired Siren if connected Select Relay Test to...

Page 20: ...sage Play Time 70 seconds Alarm Messages Not programmed Call Routing All numbers disabled Call Confirms 1 Call Attempts 3 Full Arm Setup Exit Delay ON 30 seconds Entry Delay Beep ON Exit Delay Beep ON...

Page 21: ...leads and replace the back up battery in position Reconnect the PSU Adapter plug to the DC power socket in the Control Panel and switch On the supply to the PSU Adaptor 7 As the Control Panel powers...

Page 22: ...to record a short 4 second message for use with the Latch Key facility e g system disarmed by User 1 Scroll through the menu until 2 Record User Message is displayed To record a new message press Pres...

Page 23: ...ress Enter the required alarm duration in units of 10s e g enter 6 for a 60s alarm duration max setting 60 i e 600s 10mins Press to save and exit or Press to exit without saving Press to return to top...

Page 24: ...If this is set to ON Until Disarm then the relay will latch and remain On until the system is next disarmed Default setting ON Until Disarm Scroll through the menu until 2 6 Alarm Relay is displayed T...

Page 25: ...within the UK are now operating on a Tone DTMF based exchange Default setting Tone DTMF Scroll through the menu until 2 11 Dial Method is displayed The current setting will also be displayed To change...

Page 26: ...andard intruder monitoring with normal ARM and PART ARM functions 24 Hour Intruder used to provide 24 hour monitoring of areas requiring continuous security protection even while the system is Disarme...

Page 27: ...cility is available on the zone Default setting OFF Scroll through the menu until 3 4 Z01 Chime is displayed The current setting will also be displayed To change the setting press Press to enable the...

Page 28: ...s armed Default setting OFF Scroll through the menu until 3 7 Z01 Part Arm 2 is displayed The current setting will also be displayed To change the setting press Press to enable the Zone in Part Arm 2...

Page 29: ...out changing Note After recording the message press to stop the recorder and cancel any remaining message time Press to return to the top level Voice Dialler setup menu Replay Alarm Messages Scroll th...

Page 30: ...croll through the menu until 5 1 EXIT DELAY is displayed The current settings will also be displayed To change the settings press On Off Status Default setting ON Scroll through the menu until 5 1 1 S...

Page 31: ...displayed The current settings will also be displayed To change the settings press Enter the required delay period 10 to 250s Press to save and exit or Press to exit without saving Press to return to...

Page 32: ...s displayed The current setting will also be displayed To change the setting press Press to enable the entry delay beep or Press to disable the entry delay beep Exit Delay Beep This controls the warni...

Page 33: ...red is displayed The current status will also be displayed To change the setting press Press to enable the Latch Key for the user or Press to disable the Latch Key for the user After configuring all U...

Page 34: ...menu until 12 REMOTE MANAGER SETUP is displayed and press Note After completing the Remote Manager setup press to return to the top level programming menu Telephone Number Scroll through the menu unti...

Page 35: ...creasing in steps as the delay expires If the system has not been disarmed when the Entry Delay expires an alarm will occur If however the Entry Delay for the triggered zone has been disabled an alarm...

Page 36: ...the event of threat or danger by activating a Panic Button on either the Remote Control or the Control Panel Remote Control Slide the Panic Button on the side of the Remote Control upwards Control Pa...

Page 37: ...deleting the message just heard To delete the message Press to delete the message Press to re confirm and actually delete the message Note Press at either stage to cancel delete and move on to the ne...

Page 38: ...attery indication will be activated In addition if any PIR or Magnetic Contact Detector has a low battery status it will be indicated on the LOW BAT LED on the Control Panel LED Glowing Magnetic Conta...

Page 39: ...iods Detectors And Remote Control The Detectors require very little maintenance The batteries should be replaced once a year or when a low battery status is indicated IMPORTANT Should you for any reas...

Page 40: ...Phone Numbers Phone No 1 Phone No 2 Remote Security Manager Service Phone No System ID No This information is confidential and should be kept in a safe location 40 Alarm Record Complete the following...

Page 41: ...ted or faulty check phone line with another phone 2 Dial Method incorrectly programmed 3 Answer Phone disabled 4 No space in message store 6 messages already recorded Cannot record Voice Memo message...

Page 42: ...the detector is not in a draughty area 5 Pulse count set too low reset to two pulse detection PIR Movement Detector not detecting a person s movement 1 Check battery connections are good 2 Pulse coun...

Page 43: ...your statutory rights and is valid for UK and EIRE only If you believe the product to be faulty or in the unlikely event of the product developing a fault during the warranty period then please contac...

Page 44: ...Piezo Siren 3 minute alarm duration limiter optional Auto reset Siren Disable selectable Dual front and rear anti tamper protection Jamming Detection Audible confirmation Passive Infra Red Movement De...

Reviews: