www.response-technologies.com
- 12 -
©Response Technologies, Ltd.
Revised: January 9, 2015
Section 4
System Configuration
RELAY CONFIGURATION
Note: This section refers to the SCOUT External Relay Cable (R3136). The SCOUT External
Relay Cable (R3136) is sold separately as an optional accessory.
Input Relay
The Input Relay allows the user to activate the
SCOUT
using any Normally Open or Normally
Closed latching device. The
SCOUT
will activate every 5 minutes while the device remains
latched or until the system is disarmed. The
SCOUT
must be off and the external device must be
in its non-alarm state when connecting the two input relay wires in order for the
SCOUT
to
recognize the correct non-alarm state when turned on.
GREEN WIRE – Input
ORANGE WIRE – Input
Output Relay
The Output Relay allows the user to have the
SCOUT
activate any Normally Open or Normally
Closed contact activated device upon
SCOUT
sensor activation. By default the relay will remain
latched for 30 seconds. Latch time is configurable with provided Console software (See Console
Configuration – Section 5).
BLACK WIRE – Common
WHITE WIRE – Normally Open
RED WIRE – Normally Closed