background image

3. DIP 4 of SW3 is used to configure the PIR Detector for

walk  test  mode,  which  allows  the  operation  of  the

Detector  to  be  checked  during  installation  without

triggering a Full Alarm.

Note: On initial installation the PIR Detector should be

set to Walk-Test mode ready for testing.

4. The  PIR  Detector  incorporates  a  sensitivity  feature

designed  to  compensate  for  situations  where  the

Detector  may  be  affected  by  environmental  changes,

(e.g. insects, air temperature, etc).  This feature is called

“Detection  Sensitivity”  and  may  be  set  to  Standard  or

High Sensitivity.

Note: The  higher  the  sensitivity  the  less  movement

will  be  necessary  before  the  PIR  Detector  will  trigger

the alarm.

The  recommended  setting  is  Standard  Sensitivity.  If

set  to  High  Sensitivity,  in  some  cases,  extreme

environmental  problems  could  cause  unattributed

false alarms. If this is experienced it may be necessary

to reset the PIR Detector to Standard Sensitivity.

Set  the  required  detection  sensitivity  using  DIP  5  of

SW3 as follows:

5. Connect the PP3 alkaline battery to the battery clip.  

Note: When the 9V alkaline battery is connected, the

LED behind the lens will flash for 2-3 minutes until the

PIR has warmed-up and stabilized. The LED will then

stop flashing and turn OFF.

Testing The PIR Detector

Before  testing  the  PIR  Detector  ensure  that  the

system is in Test mode (for a Control Panel System) or

Service Mode (for a Siren only System).

With the PIR Detector set in Walk Test mode (Switch 4) and

mounted  in  position  on  the  wall,  allow  2-3  minutes  for  the

PIR Detector to stabilize before commencing the Walk Test.

1. Walk into and move slowly around the protected area,

each  time  the  PIR  Detector senses  your  movement

the LED behind the Lens will flash.  

If  necessary  re-adjust  the  detection  pattern  by

changing the mounting position of the PCB within the

PIR housing.

2. Reconfigure the PIR Detector for normal operation mode

by setting DIP4 of SW3 to OFF and refit in position.

Note: In  normal  operation,  the  LED  behind  the  PIR

Detector lens  will  not  flash  on  movement  detection,

(unless the battery is low). 

Note: When  the  PIR  Detector is  fully  installed  i.e.

battery  cover  is  refitted;  the  unit  will  not  detect

movement  for  approximately  45  seconds  after  each

activation.  (This feature is present to conserve battery

power and maximize the battery life).

Disposal and Recycling

Disposal  of  this  product  is  covered  by

the  Waste  Electrical  or  Electronic

Equipment (WEEE) Directive.  

It should not be disposed of with other

household or commercial waste.  

At  the  end  of  its  useful  life  the  packaging  and  product

should  be  disposed  of  via  a  suitable  recycling  centre.

Please  contact  your  local  authority  or  the  retailer  from

where  the  product  was  purchased  for  information  on

available facilities.

OFF

Standard Sensitivity

ON

High Sensitivity

DIP 4

Mode

Trigger reaction 

of SW3

on LED

ON

Walk

• LED single flash when 

Test

movement detected: 

implies the sensor is

set to high sensitivity

• LED flashes three times

and illuminates once: 

implies the sensor is 

set to low sensitivity

OFF

Normal

LED will not light up

Position

(unless the battery in the 

PIR is low)

Reviews: