Response Electronics SAP E Installation And Operating Instructions Download Page 2

Installing and Configuring the
PIR Detectors

Ensure that the system is in Test or Service Mode

1. Undo  and  remove  the  fixing  screw  from  the  bottom

edge  of  the  PIR  Detector.  Carefully  pull  the  bottom

edge of the PIR Detector away from the rear cover and

then slide down to release the top clips.

2. Carefully  drill  the  required  mounting  holes  in  the  rear

cover  using  a  3mm  drill  relevant  to  whether  the 

PIR Detector is being mounted in a corner or against

a flat wall.

3. Using the rear cover as a template, mark the positions

of the fixing holes on the wall.

4. Fix the rear cover to the wall using the two 18mm No.4

screws  and  25mm  wall  plugs,  (a  5mm  hole  will  be

required  for  the  wall  plugs).    Do  not  over-tighten  the

fixing screws as this may distort or damage the cover.

Note: The wall plugs supplied with the product are not

suitable  for  plasterboard  walls,  if  mounting  the  PIR

Detector onto plasterboard use appropriate wall plugs.

5. Configure  the  PIR  Detector  as  described  below.

Remember that on initial installation the device needs to

be tested and should therefore be set in Walk Test Mode.

6. Check that the PIR Detector PCB is located and set in 

the correct position to give the detection zone pattern

required.

To adjust the PCB position, simply slide it up or down

ensuring  that  the  location  legs  are  aligned  with  the

required position number marked on the board.

7. To refit the PIR Detector to the rear cover, offer it up to

the rear cover and locate the clips in the top edge into

the rear cover.  Push the lower edge of the PIR Detector

into place and refit the fixing screw in the bottom edge

to  secure  in  position.    Do  not  over-tighten  the  fixing

screws as this may damage the casing.

Setting the PIR Detectors

Located on the PCB of the PIR Detector are two blocks

of DIP switches (SW2 and SW3).

When setting Dip Switches to House Code, hold the PIR

Detector ‘upside down’ as shown in the diagram below:

1. DIP switches SW2 (numbered 1-8) are used to set the

House Code for the PIR Detector and must be set to

the  same  ON/OFF  combination  as  the  House  Code

DIP switches in all other system devices.

2. Set  the  alarm  zone  which  the  PIR  Detector will

operate on, with DIP switches 1-3 of SW3 as follows:

Setting for Siren only Alarm System

For a Siren only Alarm System, DIP switches 1-3 of SW3

must be set as follows:

Setting for an Alarm System with a Control Panel

If your system has a Control Panel, DIP Switches 1-3 of

SW3 should be set as follows:

Rear Cover

Fixing Screw

Mounting Hole

Positions

8

7

6

5

4

3

2

1

2

1

4

3

5

EC

E

EC

E

ON

ON

SW

3

SW

2

5

4

3

2

1

DIP Switches

(SW2 and SW3)

PCB Board

(slides up and

down to adjust

position)

ON

ECE

ON

ECE

1   2   3   4   5   6   7   8

1   2   3   4   5

SW3

SW2

Set to House Code

Zone

Settings

Walk Test

Sensitivity

DIP 1

ON

DIP 2

ON

DIP 3

OFF

Zone 1

Zone 2

Zone 3

Zone 4

Zone 5

Zone 6

DIP 1

OFF

OFF

OFF

OFF

ON

ON

DIP 2

OFF

OFF

ON

ON

OFF

OFF

DIP 3

OFF

ON

OFF

ON

OFF

ON