Installing and Configuring the
PIR Detectors
Ensure that the system is in Test or Service Mode
1. Undo and remove the fixing screw from the bottom
edge of the PIR Detector. Carefully pull the bottom
edge of the PIR Detector away from the rear cover and
then slide down to release the top clips.
2. Carefully drill the required mounting holes in the rear
cover using a 3mm drill relevant to whether the
PIR Detector is being mounted in a corner or against
a flat wall.
3. Using the rear cover as a template, mark the positions
of the fixing holes on the wall.
4. Fix the rear cover to the wall using the two 18mm No.4
screws and 25mm wall plugs, (a 5mm hole will be
required for the wall plugs). Do not over-tighten the
fixing screws as this may distort or damage the cover.
Note: The wall plugs supplied with the product are not
suitable for plasterboard walls, if mounting the PIR
Detector onto plasterboard use appropriate wall plugs.
5. Configure the PIR Detector as described below.
Remember that on initial installation the device needs to
be tested and should therefore be set in Walk Test Mode.
6. Check that the PIR Detector PCB is located and set in
the correct position to give the detection zone pattern
required.
To adjust the PCB position, simply slide it up or down
ensuring that the location legs are aligned with the
required position number marked on the board.
7. To refit the PIR Detector to the rear cover, offer it up to
the rear cover and locate the clips in the top edge into
the rear cover. Push the lower edge of the PIR Detector
into place and refit the fixing screw in the bottom edge
to secure in position. Do not over-tighten the fixing
screws as this may damage the casing.
Setting the PIR Detectors
Located on the PCB of the PIR Detector are two blocks
of DIP switches (SW2 and SW3).
When setting Dip Switches to House Code, hold the PIR
Detector ‘upside down’ as shown in the diagram below:
1. DIP switches SW2 (numbered 1-8) are used to set the
House Code for the PIR Detector and must be set to
the same ON/OFF combination as the House Code
DIP switches in all other system devices.
2. Set the alarm zone which the PIR Detector will
operate on, with DIP switches 1-3 of SW3 as follows:
Setting for Siren only Alarm System
For a Siren only Alarm System, DIP switches 1-3 of SW3
must be set as follows:
Setting for an Alarm System with a Control Panel
If your system has a Control Panel, DIP Switches 1-3 of
SW3 should be set as follows:
Rear Cover
Fixing Screw
Mounting Hole
Positions
8
7
6
5
4
3
2
1
2
1
4
3
5
EC
E
EC
E
ON
ON
SW
3
SW
2
5
4
3
2
1
DIP Switches
(SW2 and SW3)
PCB Board
(slides up and
down to adjust
position)
ON
ECE
ON
ECE
1 2 3 4 5 6 7 8
1 2 3 4 5
SW3
SW2
Set to House Code
Zone
Settings
Walk Test
Sensitivity
DIP 1
ON
DIP 2
ON
DIP 3
OFF
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
DIP 1
OFF
OFF
OFF
OFF
ON
ON
DIP 2
OFF
OFF
ON
ON
OFF
OFF
DIP 3
OFF
ON
OFF
ON
OFF
ON