1.2 Cautions

☻   Don’t  smoke  while  using  your  oxygen  equipment  or  when  you  are  near  a  person 
utilizing  oxygen  therapy.keep  matches,cigarettes,burning  tobacco,or  candles  away 
from the area where the system is being stored or operated.

☻ Use No Oil or Grease:A spontaneous and violent ignition may occur if oil,grease,or 
other  petroleum  substances  come  into  contact  with  oxygen  under  pressure.keep  these 
substances away from the oxygen system,tubing and connections,and any other oxygen 
source.Don’t use any petroleum based or other lubricants.

☻  Don’t  leave  oxygen  equipment  running  when  not  in  use.Don’t  leave  cannula 
unattended  while  unit  is  delivering  oxygen.High  concentrations  of  oxygen  can  cause 
rapid burning.keep the equipment in a well-ventilated area.

☻ Avoid creation of any spark near oxygen equipment.This includes sparks from static 
electricity created by any type of friction.

☻ Don't turn over or lay the device during carrying it.

☻ The temperature of environment in using the device should be 10~37

℃.

Don't move the device casually when the device is energizing.

☻  Don't  overfill  humidifier.Watering  the  humidifier  bottle  according  to  the  standard 
water meter of the humidifier bottle.

☻  Don't  reverse  the  oxygen  input  and  output  connections.water  from  the  humidifier 
bottle will travel through the cannula back to the patient.

☻ Use the device according to the intended use on user manual, it can't be used to life 
support.

☻  The  flow  and  use  time  of  the  device  must  be  selected  under  the  directions  of 
physicians.

☻  Advice  contained  in  this  manual  should  not  supersede  instructions  given  by  the 
physicians.

☻ It's a normal phenomenon that the device has a regular exhaust sound in using.

☻  The  device  should  only  be  matched  with  power  cord, 

humidifier  bottle  and  other  accessories  recommended  by  RMS.  It  may  effects  the 
function of device or causes some risks if you use the unapproved accessories.

☻ 

Nasal  Oxygen  Cannula

☻ The oxygen tube and humidification bottle  to be used on the machine are for single 
use and should be only provided by RMS. Otherwise some malfunction or danger may be 
caused by using unapproved accessories.

Section 1  Special Notes

Please read all instructions before using.Important information is highlighted by these terms:

1.1 Warnings

☻ Never use aerosol sprays or flammable anesthetics near the equipment.

☻  If  the  equipment  has  a  damaged  cord  or  plug,if  it  is  not  working  properly,if  it  has 
been  dropped  or  damaged,or  if  it  has  been  submersed  in  water,do  not  use  and  call  a 
qualified technician for examination and repair.

☻ Don't use the device in bathroom, if the patient needs use it continuously, you must 
put the oxygen concentrator no less than 3m away from the bathroom.

☻  Keep  all  units  away  from  children.Do  not  allow  unauthorized  or  untrained 
individuals to operate the equipment.Never try to repair the equipment yourself.if you 
have  any  questions  or  suspect  your  equipment  is  not  operating  properly,contact  your 
oxygen provider.

☻ Don't touch the device when body is wet. Don’t use or put the device in a place where 
is  easy  to  drop  into  water  or  there  is  conductive  liquid.  If  so,  pull  up  the  power  plug 
immediately.

☻  It  may  cause  an  auto-ignition  when  oils  and  fats  or  things  oily  contact  the  oxygen 
under  pressure.  Don’t  use  any  lubricant  on  oxygen  concentrator,  tubes  or  other  parts 
unless RMS recommends in writing.

☻  People  who  have  operation,  emergency  treatment,  critical  patients  and  carbon 
monoxide poisoning patients can't use the device.

☻ Don't block the air inlet of the device or put the device on a soft surface, such as sofa, 
bed and other things may block the air inlet. The air inlet should be away from the lint, 
hair or other similar things.

☻ The device should be away from the wall, tapestry, furniture and other things for no 
less than 10cm.

☻ There must be a special care when children or disabled use it.

☻ The power line should be away from the heat source or high-temperature surface.

☻  Cut  off  the  power  immediately  when  breaking  out  the  fire  and  turn  off  the  flow 
adjusting button quickly.

hoose Humidifier and Nasal Oxygen Cannula which include a means to prevent the 

propagation of fire and accordance with requirements of EN ISO 8359/A1:2012

☻ C

Warning     Warning indicates a hazardous situation which,if not avoided,could result in  

          

death or serious injury.

Caution      Caution indicates a hazardous situation which,if not avoided,may result in  

          

Property damage or minor injury or both.

Respiratory Medical Solutions

 

05

04

Summary of Contents for AO3 Series

Page 1: ...piratory equipment www rms care com EC REP Part NO 233010002 Rev 3 0 3 20 15 Manufacture Shenyang RMS Medical Tech Co Ltd Address No 8 1 Gaoge Road Hunnan New District Shenyang China Tel 0086 024 23782895 8001 Fax 0086 024 23782895 8008 KINGSMEAD SERVICE LIMITED 145 157 St John Street London EC1V 4PY UK TEL 044 20 7193 9159 ...

Page 2: ...e Warranty Instructions Section 7 Troubleshooting Guide Troubleshooting Alarms Appendix A EMC Information 04 04 05 06 06 07 07 07 07 07 08 08 09 10 11 11 11 11 13 14 15 15 15 16 16 17 18 Drip Proof Equipment IP21 NO smoking Serial Number Indicating its conformity with the medical devices directive 93 42 EEC The 0917 is the number of notified body Proper disposal of equipment according to local law...

Page 3: ...ction 1 Special Notes Please read all instructions before using Important information is highlighted by these terms 1 1 Warnings Never use aerosol sprays or flammable anesthetics near the equipment If the equipment has a damaged cord or plug if it is not working properly if it has been dropped or damaged or if it has been submersed in water do not use and call a qualified technician for examinatio...

Page 4: ...ency so it may cause interference if using the portable communication equipments near the device 1 4 Intended Use Medical oxygen concentrator Model AO3 AO3W AO5 AO5W used for separating oxygen from air EUT not intended to be used for emergency treatment and patient who has serious carbon monoxide poisoning cannot use this device Section 2 Packaging And Handling 2 1 Unpacking Check for any obvious ...

Page 5: ...test Oxygen Concentration Testing Circuit Breaker Power Switch Power Socket Filter Device Tag LCD Screen Control Buttons Caste Handle Warning Tag Oxygen Outlet Inlet Filter Window Compressed Air Output Humidifier Bottle Section 3 Features 3 1 Parts and Functions Flow Regulating Button Filter Oxygen Outlet Control Buttons Respiratory Medical Solutions 09 08 ...

Page 6: ...backpressure is 0 and the rated flow is 3L min giving a 7kpa backpressure can make the flow being 2 8 L min If the power network isn t stable the power voltage fluctuate over 10 please use it after installing a voltage stabilizer Make sure the environment nearby dry ventilated no dust and any other caustic gas no strong electromagnetic interference This device can be used normally below the height...

Page 7: ...en tube and check the power cord using it continuously after troubleshooting Press On Off button to use it continuously after the external power regaining End of use Press the On Off button to stop the device working after finished using and turn off the power cord Take down the power line if you don t often use it 5 4 Operating Panel and LCD Screen Start Stop Plus Key Minus Key Timer Key Mode Oxy...

Page 8: ...e The damage caused by human error fault operation konck moving liquid infiltration etc The damage by natural disasters or accidents Other accessories not listed for warranty Oxygen Concentration 0 1 2 3 4 This time 00 00 h min Timer off h min Flow L min 5 5 Operating Method Operation interface Display working mode alarm information oxygen concentration oxygen flow present service time timing time...

Page 9: ...ndicator flashing Continuous Alarm Concentrator not operating Press start stop the alarm stops Call service provider indicator flashing Continuous Alarm start stop the alarm stops Call service provider Concentrator not operating The red low pressure indicator flashing Continuous Alarm Press start stop the alarm stops Call service provider Concentrator not operating The red hign pressure indicator ...

Page 10: ...3 3 Vrms 150 kHz to 80 MHZ outside ISM bandsa 3 V m 80 MHz to 2 5 GHz 3V 3V m Portable and mobile RF communications equipment should be used no closer to any part of the XXXXXXX including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Guidance and manufacturer s declaration electromagnetic immunity This device is intended...

Reviews: