13  List of spare parts

11

2

5

1

3

6

7

8

10

4

9

Pos. Art. no.

Article

1

11201100 Safety valve 6 bar DN20

2

11200039 Pressure gauge

3

11200058 Fill / drain  valve

4

11201103

Return ball valve with non-return valve and thermometer 
handle DN 25

5

11200058 Fill / drain  valve

6

64400075

Wilo Stratos PARA 15/1-9

7

11201105 Flowmeter  5 … 35  l/min

8

11201106

Flow ball valve with non-return valve and thermometer handle 
DN 25

9

11201107 Air separator DN25

10

11201101 Back half of the insulation XL

11

11201102 Front half of the insulation XL

12

11201108 Wall mounting bracket XL (not shown)

13

11201117 Controller panel (not shown)

11  Accessories

SBS 2000 filling and flushing station
The SBS 2000 has been especially designed for profes-
sionally  filling  and  flushing  solar  thermal  and  heating 
systems. Its many thought-out details facilitate transport, 
operation and cleaning, the attractive design makes it the 
ideal companion for a professional performance.

Heat transfer and cleaning fluids
In  our  product  portfolio,  you  will  find  a  range  of  heat 
transfer  fluids  for  different  applications,  available  as 
readymix or concentrate, as well as cleaning fluids.

Filling and injection pump
Filling and injection pump with non-return valve for pres-
sure increase and refilling of heat transfer fluids. ½" ET 
self-sealing with O-ring, 15mm tube connection. Pump 
output 2 l/min, 4,5 bar max.
See our full range of accessories on our website: www.
resol.com

12  Information about the pump

Depending on the version, the station is equipped with different pumps. Data con-
cerning the pump in your station are available at the pump manufacturer under 
www.wilo.com or www.wilointec.com
Upon request we will provide you with further information.

Summary of Contents for FlowSol XL

Page 1: ...this RESOL product Please read this manual carefully to get the best performance from this unit Please keep this manual carefully FlowSol XL www resol com Manual en Installation Operation Commissioni...

Page 2: ...trical works Initial installation must be effected by the system owner or qualified personnel named by the system owner Contents 1 Overview 3 2 Mounting the station 4 3 Flushing and filling the solar...

Page 3: ...m into account Ball valves in flow and return with non return valves and thermometer handles Non return valve Opening pressure 20 mbar openable Thermometer 0 160 C Connection to expansion vessel 1 ET...

Page 4: ...ing bracket Insert the flow and return lines into the wall mounting bracket and fasten them by means of the locking springs Connect the pipework between pump station and store and collector re spectiv...

Page 5: ...essary Slowly discharge the heat transfer fluid by means of the drain valve 3 until the operating pressure is set Remove the hoses of the filling and flushing station and screw the caps onto the fill...

Page 6: ...he union nut at the pressure side Now dismount the pump 10 Safety devices The pump station is equipped with a diaphragm safety valve which corresponds to the relavant directives and regulations For in...

Page 7: ...ing solar thermal and heating systems Its many thought out details facilitate transport operation and cleaning the attractive design makes it the ideal companion for a professional performance Heat tr...

Page 8: ...r the completeness of the drawings and texts of this manual they only represent some examples They can only be used at your own risk No liability is assumed for incorrect incomplete or false informati...

Reviews: