Safety advice

Please pay attention to the following safety advice in order to avoid danger and 
damage to people and property.

Instructions

Attention must be paid to the valid local standards, regulations and directives!

Information about the product
Proper usage

The pump station may only be used in the solar circuit of solar thermal systems in 
compliance with the technical data specified in these instructions. Due to its design 
the station must be mounted and operated as described in these instructions!

CE-Declaration of conformity

The product complies with the relevant directives and is therefore la-
belled with the CE mark. The Declaration of Conformity is available upon 
request, please contact RESOL.

Target group

These instructions are exclusively addressed to authorised skilled personnel.
Only qualified electricians should carry out electrical works.
Initial  installation  must  be  effected  by  the  system  owner  or  qualified  personnel 
named by the system owner.

Contents
1 Overview .............................................................................................. 3

Mounting the station ........................................................................... 4

Flushing and filling the solar system.................................................. 4

Ball valve positions .............................................................................. 5

Draining the system ............................................................................ 5

Non-return valves ................................................................................ 5

7 Flowmeter ............................................................................................ 6

Air separator ....................................................................................... 6

9 Maintenance ......................................................................................... 6
10  Safety devices ....................................................................................... 6
11 Accessories .......................................................................................... 7
12  Information about the pump ............................................................. 7
13  List of spare parts ................................................................................ 7

Description of symbols

WARNING!

Warnings are indicated with a warning triangle!

 

Î

They contain information on how to avoid the danger 
described.

Signal words describe the danger that may occur, when it is not avoided.
•  WARNING means that injury, possibly life-threatening injury, can occur.
•  ATTENTION means that damage to the appliance can occur.

Note
Notes are indicated with an information symbol.

 

Î

Arrows indicate instruction steps that should be carried out.

Disposal

•  Dispose of the packaging in an environmentally sound manner.
•  Dispose of old appliances in an environmentally sound manner. Upon request we 

will take back your old appliances bought from us and guarantee an environmen-
tally sound disposal of the devices.

Summary of Contents for FlowSol XL

Page 1: ...this RESOL product Please read this manual carefully to get the best performance from this unit Please keep this manual carefully FlowSol XL www resol com Manual en Installation Operation Commissioni...

Page 2: ...trical works Initial installation must be effected by the system owner or qualified personnel named by the system owner Contents 1 Overview 3 2 Mounting the station 4 3 Flushing and filling the solar...

Page 3: ...m into account Ball valves in flow and return with non return valves and thermometer handles Non return valve Opening pressure 20 mbar openable Thermometer 0 160 C Connection to expansion vessel 1 ET...

Page 4: ...ing bracket Insert the flow and return lines into the wall mounting bracket and fasten them by means of the locking springs Connect the pipework between pump station and store and collector re spectiv...

Page 5: ...essary Slowly discharge the heat transfer fluid by means of the drain valve 3 until the operating pressure is set Remove the hoses of the filling and flushing station and screw the caps onto the fill...

Page 6: ...he union nut at the pressure side Now dismount the pump 10 Safety devices The pump station is equipped with a diaphragm safety valve which corresponds to the relavant directives and regulations For in...

Page 7: ...ing solar thermal and heating systems Its many thought out details facilitate transport operation and cleaning the attractive design makes it the ideal companion for a professional performance Heat tr...

Page 8: ...r the completeness of the drawings and texts of this manual they only represent some examples They can only be used at your own risk No liability is assumed for incorrect incomplete or false informati...