F lo w C o n  S

|

Solar pump station with integrated controller

•  Integrated  

D e lt a S o l

®

 BS or 

D e lt a S o l

®

 BS Plus controller

•  Outstanding design

•  Safety assembly with relief valve and pressure 

gauge

•  Flushing and filling unit

•  Wall mounting with screws and dowels

•  Insulated casing

Technical data: 
Material: 
 
fittings: bras 

 

flat sealings: Klingerit, max. 200°C   
O­ring­seal:  VITON / EPDM,  
max. 180 °C 

 

Solar non­return valve: PPS,  
max. 180 °C 

 

Insulation: EPP, max. 120 °C con­
tinuous and up to180 °C intermittent
Admissible max. temp.:  
0 ... 120 °C continuous and up to 
180 °C intermittent
Size:  
with insulation: 500 x 230 x 62 mm 
distance axis / wall: 62 mm  

Electrostatic discharge can 
lead to damage of
electronic components!

Dangerous voltage

Mounting: wall mounting
Connections: 3/4" IG
Circulation pump: WILO Star 
ST15/6 or ST 15/7 (extra cost)
Power supply: 
220 ... 240 V~
Operation pressure: max. 8 bar
Spring pressure of non-return 
valve: 
200 mm head
Flowmeter: 0,5 ... 5 l/min,  
1 ... 13 l/min (standard) or   
8 ... 30 l/min

Summary of Contents for FlowCon S

Page 1: ...F lo w C o n S Manual Flo w C o n S Installation Operation Commissioning Thank you for buying this product Read this manual carefully to get the best performance from this unit 48001120 48001120...

Page 2: ...ns the statutory provisions for prevention of industrial acci dents the statutory provisions for environmental protection the Health and Safety at Work Act 1974 Part P of the Building Regulations 2005...

Page 3: ...seal VITON EPDM max 180 C Solar non return valve PPS max 180 C Insulation EPP max 120 C con tinuous and up to180 C intermittent Admissible max temp 0 120 C continuous and up to 180 C intermittent Size...

Page 4: ...tor respectively For connecting the pipes to the compression ring connection please pay attention to the following instructions All connections are already tightened such that they have not to be tigh...

Page 5: ...before commis sioning but the final installation must contain antifreeze to protect against frost damage Close the drain valve while the filling pump is running and increase the system pressure to app...

Page 6: ...alve which corresponds to the relavant directives and regulations For installation and operation please pay attention to the following advice The safety valve has to be easily accessible The effici en...

Page 7: ...RESOL 09099_flowcon_s monen indd Flo w C o n S 7 Notes...

Page 8: ...s especially applies for copies translations micro films and the storage into electronic systems Editor RESOL Elektronische Regelungen GmbH Important notice The texts and drawings in this manual are c...

Reviews: