16 

 

 

General warnings and cautions 

 WARNING 

 

Make sure that you arrange the air tubing so that it will not twist around the head or neck. 

 

Make sure the power cord and plug are in good condition and the equipment is not 

damaged. 

 

Keep the power cord away from hot surfaces. 

 

If you notice any unexplained changes in the performance of the device, if it is making 

unusual sounds, if the device or the power supply are dropped or mishandled, or if the 

enclosure is broken, discontinue use and contact your care provider or your ResMed 

Service Center. 

 

Do not open or modify the device. There are no user serviceable parts inside. Repairs and 

servicing should only be performed by an authorized ResMed service agent. 

 

Beware of electrocution. Do not immerse the device, power supply or power cord in water. 

If liquids are spilled into or onto the device, unplug the device and let the parts dry. Always 

unplug the device before cleaning and make sure that all parts are dry before plugging it 

back in. 

 

Supplemental oxygen must not be used while smoking or in the presence of an open 

flame. 

 

Always make sure that the device is turned on and airflow generated before the oxygen 

supply is turned on. Always turn the oxygen supply off before the device is turned off, so 

that unused oxygen does not accumulate within the device enclosure and create a risk of 

fire. 

 

Do not perform any maintenance tasks while the device is in operation. 

 

The device should not be used adjacent to or stacked with other equipment. If adjacent or 

stacked use is necessary, the device should be observed to verify normal operation in the 

configuration in which it will be used. 

 

The use of accessories other than those specified for the device is not recommended. They 

may result in increased emissions or decreased immunity of the device. 

 

Regularly check the antibacterial filter for signs of moisture or other contaminants, 

particularly during nebulization or humidification. Failure to do so could result in increased 

breathing system resistance. 

 CAUTION 

 

Use only ResMed parts and accessories with the device. Non-ResMed parts may reduce the 

effectiveness of the treatment and/or damage the device. 

 

Use only vented masks recommended by ResMed or by the prescribing doctor with this 

device. Fitting the mask without the device blowing air can result in rebreathing of exhaled 

air. Make sure that the mask vent holes are kept clear and unblocked to maintain the flow 

of the fresh air into the mask. 

 

Be careful not to place the device where it can be bumped or where someone is likely to 

trip over the power cord. 

 

Blocking the air tubing and/or air inlet of the device while in operation could lead to 

overheating of the device. 

 

Keep the area around the device dry, clean and clear of anything (eg, clothes or bedding) 

that could block the air inlet or cover the power supply unit. 

 

Do not place the device on its side as water might get into the device. 

 

Incorrect system setup may result in incorrect mask pressure reading. Ensure the system is 

correctly set up. 

Summary of Contents for AIRCurve 10 S

Page 1: ...rnal use only Not for printing or web publishing 1 DOCUMENT SCOPE This guide has been developed in Author it The content is written in AMER Eng in order to make sure that only one language AmE is used...

Page 2: ...buildings and the weather Wireless communication depends on network availability Coverage is not available everywhere and varies by service Technical Specifications classification Update classificatio...

Page 3: ...idifier is intended for single patient use in the home environment and re use in a hospital institutional environment At a glance section explanation of UI icons Updated to include the Wireless transf...

Page 4: ...ing pressure range Included ST T Technical specification Supplemental Oxygen Included ST T REVISION 2 Backwards compatible change Changes trigger new document numbers for published multis Section Head...

Page 5: ...ER Eng Remove instances of hPA from guide with exception of Environmental conditions Operating altitude Sea level to 8 500 2 591 m air pressure range 1013 hPa to 738 hPa All translation based on this...

Page 6: ...ot to be reproduced or made available to third parties without prior consent from ResMed and not to be used in any unauthorised way ResMed Ltd 2016 DOC NO 378015 PAGE 6 of 35 SPECIFICATION PRINTED MAT...

Page 7: ...User guide...

Page 8: ...User guide English User guide 378015r5_Covers indd 2 1 08 2016 1 45 41 PM...

Page 9: ...378015r5_Covers indd 3 1 08 2016 1 45 41 PM...

Page 10: ...leep apnea OSA in patients weighing more than 66 lb 30 kg It is intended for home and hospital use The humidifier is intended for single patient use in the home environment and re use in a hospital in...

Page 11: ...The AirCurve 10 includes the following Device with HumidAir integrated humidifier Water tub Air tubing Power supply unit Travel bag SD card not available in all devices Contact your care provider for...

Page 12: ...r three seconds to enter power save mode Dial Turn to navigate the menu and press to select an option Turn to adjust a selected option and press to save your change Home button Press to return to the...

Page 13: ...into the power outlet 3 Connect the air tubing firmly to the air outlet located on the rear of the device 4 Open the water tub and fill it with distilled water up to the maximum water level mark Do no...

Page 14: ...ht sensor that adjusts the screen brightness based on the light in the room Stopping therapy 1 Remove your mask 2 Press Start Stop or if SmartStart is enabled therapy will stop automatically after a f...

Page 15: ...care provider but you may find you want to make small adjustments to make your therapy more comfortable Highlight My Options and press the dial to see your current settings From here you can personali...

Page 16: ...ontrol delivers more comfortable therapy Mask Fit Mask Fit is designed to help you assess and identify possible air leaks around your mask To check Mask Fit 1 Fit the mask as described in the mask use...

Page 17: ...it gently and pull it away from the device 2 Open the water tub and discard any remaining water 3 Hold the cuff of the air tubing and gently pull it away from the device 4 Hold both the cuff of the ai...

Page 18: ...eusable 2 Place a new air filter onto the air filter cover and then close it Make sure the air filter is fitted at all times to prevent water and dust from entering the device Reassembling When the wa...

Page 19: ...in all regions Please be aware that within the wireless network the availability and quality of the network may be affected by terrain buildings and the weather Wireless communication depends on netw...

Page 20: ...ggage Medical devices do not count toward your carry on luggage limit You can use your AirCurve 10 device on a plane as it meets the Federal Aviation Administration FAA requirements Air travel complia...

Page 21: ...imateLineAir heated air tubing see the ClimateLineAir user guide My mouth is very dry and uncomfortable Air may be escaping through your mouth Increase the Humidity Level You may need a chin strap to...

Page 22: ...may be in Airplane Mode Turn off Airplane Mode see Traveling by plane Data transfer is not enabled for your device Talk to your care provider about your settings My screen and buttons are flashing So...

Page 23: ...nnect the power supply and then reconnect it to restart the device Air filter may be blocked Check the air filter and replace it if there are any blockages Disconnect the power supply and then reconne...

Page 24: ...e You can easily reassemble them as described below To insert the water tub seal 1 Place the seal into the lid 2 Press down along all edges of the seal until it is firmly in place To reassemble the wa...

Page 25: ...peration The device should not be used adjacent to or stacked with other equipment If adjacent or stacked use is necessary the device should be observed to verify normal operation in the configuration...

Page 26: ...temperature conditions 104 F 40 C the device remains safe Operating humidity 10 to 95 relative humidity non condensing Operating altitude Sea level to 8 500 2 591 m air pressure range 1013 hPa to 738...

Page 27: ...ded plastic stainless steel and silicone seal Cleanable water tub material Injection molded plastic stainless steel and silicone seal Temperature Maximum heater plate 154 F 68 C Cut out 165 F 74 C Max...

Page 28: ...g 6 Water tub 7 Device 8 Inlet filter Design life Device power supply unit 5 years Cleanable water tub 2 5 years Standard water tub air tubing 6 months General The patient is an intended operator Humi...

Page 29: ...0 L min 0 1 L min Ti 0 1 4 0 sec 0 1 sec I E ratio 1 100 2 1 0 1 Value Accuracy1 Pressure measurement1 Mask pressure2 0 5 cm H2O 0 5 hPa 4 of measured value Flow and flow derived values1 Flow 6 L min...

Page 30: ...0 5 0 5 0 5 0 8 0 8 20 0 5 0 5 0 5 0 5 0 8 0 8 25 0 4 0 3 0 6 0 5 0 8 0 8 Pressure accuracy bilevel Maximum dynamic pressure variation according to ISO 80601 2 70 2015 Device without humidification an...

Page 31: ...42 0 02 0 66 0 01 20 BPM 0 05 0 21 0 38 0 01 0 31 0 02 0 50 0 02 0 37 0 02 0 57 0 02 0 43 0 02 0 65 0 02 0 48 0 02 0 68 0 02 Note The table above is based on data that covers between 60 1 and 88 8 of...

Page 32: ...natural resources and prevent hazardous substances from damaging the environment If you need information on these disposal systems please contact your local waste administration The crossed bin symbol...

Page 33: ...oid on product sold or resold outside the region of original purchase Warranty claims on defective product must be made by the initial consumer at the point of purchase This warranty replaces all othe...

Page 34: ...378015r5_Covers indd 4 1 08 2016 1 45 41 PM...

Page 35: ...e Ave Milton Park Abingdon Oxfordshire OX14 4RW UK See www resmed com for other ResMed locations worldwide For patent information see www resmed com ip AirCurve Air10 ClimateLine HumidAir and SlimLine...

Reviews: