VR8300 CONTINUOUS PILOT COMBINATION GAS CONTROL

69-0668—05

2

INSTALLATION

When Installing this Product...

1.

Read these instructions carefully. Failure to follow 

them could damage the product or cause a hazard-

ous condition.

2.

Check the ratings given in the instructions and on 

the product to make sure the product is suitable for 

your application.

3.

Installer must be a trained, experienced service 

technician.

4.

After installation is complete, check out product 

operation as provided in these instructions.

WARNING

Fire or Explosion Hazard.

Can cause property damage, severe injury, or 

death.

Follow these warnings exactly:

1.

Disconnect power supply before installing or 

servicing.

2.

   To avoid dangerous accumulation of fuel gas, 

turn off gas supply at the appliance service 

valve before starting installation, and perform 

Gas Leak Test after completion of installa-

tion.

3.

Do not bend pilot tubing within 3” of the gas control 

or pilot burner after compression fitting has 

been tightened, or gas leakage at the connec-

tion may result.

4.

Always install sediment trap in gas supply line to 

prevent contamination of gas control.

5.

Do not force gas control knob. Force or attempted 

repair may result in fire or explosion. Use only 

your hand to push down the reset button or 

turn the gas control knob. Never use any 

tools. If the gas control knob or reset button 

does not operate by hand, the gas control 

should be replaced by a qualified service 

technician.

CAUTION

Equipment Hazard.

Improper installation can burn out thermostat 

heat anticipator.

Do not apply a jumper across or short the valve 

coils.

IMPORTANT

These gas controls are shipped with protective 

seals over inlet and outlet tappings. Do not 

remove seals until ready to connect piping.

Follow the appliance manufacturer instructions if 

available; otherwise, use the instructions provided below.

Converting Between Natural Gas 
and LP Gas

If needed, convert valve between Natural and LP gas.

WARNING

Fire or Explosion Hazard.

Can cause property damage, severe injury, or 

death.

1.

Do not use a gas control set for natural gas on LP 

gas or a gas control set for LP gas on natural 

gas.

2.

When making the conversion, the main and pilot 

burner orifices MUST be changed to meet 

the specifications of the appliance manufac-

turer.

Standard or slow-opening gas controls can be converted 

from one gas to another. To convert from natural gas to 

LP, use the 393691 LP Conversion Kit. To convert from LP 

to natural gas, use the 394588 Natural Gas Conversion 

Kit. Step-opening gas controls cannot be converted.

To convert the control from one gas to another:

1.

Turn off the main gas supply to the appliance.

2.

Remove the regulator cap screw and pressure reg-

ulator adjusting screw. See Fig. 1.

3.

Remove the existing spring.

4.

Insert the replacement spring with the tapered end 

down. See Fig. 2.

5.

Install the new plastic pressure regulator adjust-

ment screw so that the top of the screw is flush 

(level) with the top of the regulator. Turn the pres-

sure regulator adjustment screw clockwise 

 

six complete turns. This provides a preliminary 

pressure setting of about 10.0 in. wc (2.5 kPA) for 

an LP regulator and a 3.5 in. wc (0.9 kPA) for a nat-

ural gas regulator.

6.

Check the regulator setting with a manometer or by 

clocking the gas meter after gas control is 

installed. See the Startup and Checkout section.

7.

Install the new cap screw.

8.

Mount the conversion label on the control.

Install the control according to the appliance 

manufacturer instructions.

Fig. 1. Top view of gas control.

OUTLET

PRESSURE 

TAP

INLET

OUTLET

WIRING

TERMINALS (2)

OUTLET

PRESSURE 

TAP

PRESSURE REGULATOR

ADJUSTMENT

(UNDER CAP SCREW)

PILOT OUTLET

PILOT ADJUSTMENT

(UNDER CAP SCREW)

GAS 

CONTROL

KNOB

RED RESET BUTTON

M16013A

THERMOCOUPLE

CONNECTION

CONVENIENCE

TERMINALS (2)

(OPTIONAL)

Summary of Contents for VR8300A

Page 1: ...equency 24 Vac 50 60 Hz Current Draw 0 70A Table 1 Temperature Range and Regulatory Type Table 2 Capacity a Capacity based on 1000 Btu cu ft 0 64 specific gravity natural gas at 1 in wc pressure drop 37 3 MJ cu m 0 64 specific gravity natural gas at 0 25 kPa pressure drop Use conversion factors in Table 3 to convert capacities for other gases Table 3 Gas Capacity Conversion Factors Table 4 Flange ...

Page 2: ... if available otherwise use the instructions provided below Converting Between Natural Gas and LP Gas If needed convert valve between Natural and LP gas WARNING Fire or Explosion Hazard Can cause property damage severe injury or death 1 Do not use a gas control set for natural gas on LP gas or a gas control set for LP gas on natural gas 2 When making the conversion the main and pilot burner orific...

Page 3: ...rol following the same precautions and instructions that are used for installing the gas control After the adapter is installed the gas control is attached to the adapter as outlined above Note that using an adapter increases the overall length of the gas control Choose Gas Control Location Do not locate the gas control where it can be affected by steam cleaning high humidity dripping water corros...

Page 4: ...Do not bend tubing within 3 inches of the gas control or pilot burner after compression fitting is tightened because this can result in gas leakage at the connection 2 Square off and remove the burrs from the end of the tubing 3 Unscrew the compression fitting from the pilot out let Fig 1 Slip the compression fitting over the tubing and slide out of the way NOTE When replacing a gas control cut of...

Page 5: ...r servicing All wiring must comply with applicable electrical codes and ordinances Refer to the appliance manufacturer instructions if available or use the following procedure 1 Check the power supply rating on the gas control and make sure it matches the available supply Install the transformer thermostat and other con trols as required 2 Connect the control circuit to the gas control termi nals ...

Page 6: ...he main burner in operation paint pipe joints including adapters and gas control inlet and out let with rich soap and water solution 5 If another leak is detected tighten the adapter screws joints and pipe connections 6 Replace the part if gas leak cannot be stopped Light Pilot Burner Flame 1 Turn the gas control knob clockwise to OFF Wait five minutes to dissipate any unburned gas Sniff around th...

Page 7: ...ary adjust the pressure regulator to match the appliance rating Refer to Table 7or 8 for the factory set nominal outlet pressures and adjustment ranges a Remove the pressure regulator adjustment cap and screw b Use a screwdriver to turn the inner adjustment screw clockwise to increase or counter clockwise to decrease the main burner gas pressure c Always replace the cap screw and tighten firmly to...

Page 8: ...utdown before re energizing step opening model to ensure light off at step pressure If Pilot Burner Flame does not Light 1 Make sure that the main gas supply valve is open and the pilot gas supply line is purged of air 2 Light the pilot burner flame following procedures in Light the Pilot Burner Flame section If pilot burner flame does not light a Check the pilot gas adjustment screw If closed rea...

Page 9: ...ng 2 Disconnect all electric power to the appliance 3 Remove the gas control access panel 4 Push in the gas control knob slightly and turn clockwise to OFF NOTE The gas control knob cannot be turned from PILOT to OFF unless it is pushed in slightly Do not force the gas control knob 5 Wait five minutes to clear out any unburned gas If you then smell gas STOP Follow the instructions in step 3 IF YOU...

Page 10: ...VR8300 CONTINUOUS PILOT COMBINATION GAS CONTROL 69 0668 05 10 ...

Page 11: ...VR8300 CONTINUOUS PILOT COMBINATION GAS CONTROL 11 69 0668 05 ...

Page 12: ...chnologies Inc All rights reserved This product is manufactured by Resideo Technologies Inc and its affiliates www resideo com Resideo Technologies Inc 1985 Douglas Drive North Golden Valley MN 55422 1 800 468 1502 69 0668 05 M S Rev 06 20 Printed in United States ...

Reviews: