BATTERY REPLACEMENT 

1.  At the bottom of the keypad, remove the screw that secures the front 

cover to the rear mounting bracket. 

2.  Remove the batteries, wait 10 seconds, then insert three new 3V 

Lithium batteries (see 

Specifications 

for replacement batteries).  

3.  Align the case with the cleats and snap into place and secure with bottom 

screw

 

BATTERY CAUTION

: Risk of fire, explosion, and burns. Do not recharge, 

disassemble, heat above 55°C, or incinerate. Dispose of used batteries 
properly. Keep away from children. 

Note

: Constant exposure to high or low temperature or high humidity may 

reduce battery life. 

PANIC KEYS 

This keypad also features panic keys. These keys 
may be programmed for Fire, Police, and Medical 
alarms. Panic activation requires a 2-button 
sequence. After the first button in the sequence is 
pressed, you can cancel the panic by pressing any 
key other than one of the panic keys. 

 

Panic

 

There are 3 ways to generate an alarm: 
1. Press 

Panic

 and within 10 seconds press the 

desired panic key (

Fire

Police

Medical

). 

2.  Press desired panic key and within 10 seconds 

press the 

Panic

 button. 

3.  Press desired panic key and within 10 seconds 

press the same key. 

 

Fire

 

 

Police

 

 

Medical

 

 

SPECIFICATIONS: 

Dimensions (mm) / Weight:  

153 (H) x 98 (W) x 34 (D) / 283 g 

Frequency of Operation:  

2.4 GHz 

Tamper:  

Wall (audible alert and signal sent to Control Panel)

 

Sounder:  

Piezoelectric 

Batteries:  

Three (3) - 3V Lithium batteries 

 EVE 

CR123A 

 Panasonic 

CR123A 

 Duracell 

DL123A

 

 

 

 

 

 

 

 

 

(xxxx-xxxxxx) 

www.cnpp.com

 

www.marque-nf.com

 

 

The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or 
authorized recyclers. The correct disposal of end-of-life equipment will help prevent potential negative consequences for the 
environment and human health.

 

This system must be checked by a qualified technician at least once every three (3) years.

 

Any attempt to reverse-engineer this device by decoding proprietary protocols, de-compiling firmware, or any similar actions is strictly prohibited. 

 

REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING 
LIMITATIONS OF THE ENTIRE ALARM SYSTEM 

Summary of Contents for PROSIXLEDKP-EU Series

Page 1: ... Select key SCROLL Scroll key Local Programming key 2 second hold MAX Arm Maximum key No Delay TEST System Test key BYPASS Bypass Zone key INSTANT Arm Instant key No Delay CODE Add Security Codes key CHIME Chime Mode key READY Check Zones key Quick Arm key Disarm Cancel Key Panic Alarm key Fire Panic key Police Panic key Medical Panic key Keys 0 9 Numeric keys used to enter security code s Prox Ta...

Page 2: ... can be used Registration and programming are conducted through the AlarmNet 360 cloud based management platform using the Resideo Pro App After accessing the customer account perform the following steps 1 From the Select KEYPADS 2 Select ADD KEYPAD 3 Select Learn and wait for the Control Panel to be in learning mode 4 Activate the keypad by pressing any key The keypad automatically attempts to pa...

Page 3: ...ress the desired panic key Fire Police Medical 2 Press desired panic key and within 10 seconds press the Panic button 3 Press desired panic key and within 10 seconds press the same key Fire Police Medical SPECIFICATIONS Dimensions mm Weight 153 H x 98 W x 34 D 283 g Frequency of Operation 2 4 GHz Tamper Wall audible alert and signal sent to Control Panel Sounder Piezoelectric Batteries Three 3 3V ...

Page 4: ...e go to www resideo com Sécurité Communications SAS SECOM 1198 Avenue du Docteur Maurice Donat 06250 Mougins FRANCE Ademco 1 Ltd 200 Berkshire Place Winnersh Triangle Berkshire RG41 5RD UNITED KINGDOM PROSIXLEDKP EU R800 26885B 01 22 Rev B 2022 Resideo Technologies Inc www resideo com ...

Reviews: