T6RWP Thermostat 

Control form 

 

Adaptive Fuzzy Logic 

Room 

Temperature 

display range 

 

From 0

 o

C to 50

 o

Dimensions 

(w x h x d) 

 

T6RWP (wireless) 103 x 103 x 68 mm 

 

 

Time display 

 

24 hour or 12 hour AM/PM format 

Time keeping 

accuracy 

 

Synchronized with Internet when 

connected or typically better than 10 

minutes per year  

Program 

Heating  

 

5+2 or daily schedule with 6 daily time 

and temperature level changes 

Program Hot 

water  

 

5+2 or daily schedule with 3 ON periods 

per day 

Time setting 

resolution 

 

 

Program - 10 minute steps 

Sensing 

element 

 

 

100K (@ 25

 o

C) NTC thermistor 

Temperature 

setting range 

 

Program  : 5 to 37

o

C in 0.5 

o

C steps  

OFF  

: 5

 o

 

Power 

 

5VDC  

 

ACC900 In-wall power module 

Power 

 

230VAC 

Output 

 

5VDC 

Max. 650mA 

 

Wiring (230V) 

 

Terminal block capable of accepting 

wires up to 1.5 mm

2

 

Wiring (5VDC) 

 

10 cm cable with 2 wires. 

Dimensions 

49 x 52 x 27 mm (w x h x d) 

 

IP class 

 

30 

 

RF communication 

RF operation 

band 

 

ISM (868.0-868.6) MHz, 1% duty cycle 

Max. power 

 

25mW 

 

 

 

Protocol 

 

Encrypted  

 

 

Comm. Range 

 

30 m in a residential building 

environment 

Comm.  

technology 

 

short, high rate transmissions to 

minimise air time and avoid collisions 

 

 

Receiver class 

R.E.D. 

 

RX Cat 2 (ETSI EN300 220-1 version 

1.3.1) 

 

 

RF binding 

method 

 

Factory pre-bound 

 

 

 

Wi-Fi 

 

IEEE 802.11b/g/n 

 2.4GHz 

Max. power 

 

100mW 

 

 

 

Environmental and standards 

Operating 

temperature range 

 

0 to 40

o

C  

 

Shipping and storage 

temperature 

 

-20 to 55

o

Humidity range 

 

10 to 90% rh, non-condensing 

 

 

 

Receiver Category 2  

 

868.3MHz 

Max RF Power 

 

25 mW  

Operating frequency  

 

868

868.6MHz 

 

 

 

 

 

 

Wi-Fi 

 

2.4GHz 

Max Power 

 

100mW 

Operating frequency 

 

2.4

2.458GHz 

 

 

 

ErP 

 

Class V (+3%), (EU) 811/2013 

 

Hereby, Pittway Sarl declares that that the radio 

equipment type T6H700RW is in compliance with 

Directive 2014/53/EU.  

The full text of the EU declaration of conformity is 

available at the following internet address: 

https://hwllhome.co/DoC 

 

Summary of Contents for Honeywell Home T6H700RW5001

Page 1: ...back to the user installer High LCD Contrast and backlighting for easier viewing in all light conditions Time out screen with selectable brightness Heating control Factory programmed daily or 5 2 default schedule Schedule with up to 6 independent time and temperature pairs to suit the comfort needs Hold until temperature override of programmed schedule temperature till the next switch point Schedu...

Page 2: ...Reference to the icons Schedule period 2 ...

Page 3: ...es Dimensions 49 x 52 x 27 mm w x h x d IP class 30 RF communication RF operation band ISM 868 0 868 6 MHz 1 duty cycle Max power 25mW Protocol Encrypted Comm Range 30 m in a residential building environment Comm technology short high rate transmissions to minimise air time and avoid collisions Receiver class R E D RX Cat 2 ETSI EN300 220 1 version 1 3 1 RF binding method Factory pre bound Wi Fi I...

Page 4: ...ycle Hour Minimum ON time in minutes Note a To change Cycle Hour b To change Minimum ON Time Heating Gas Boilers 30KW 6 1 No action required Oil Boiler 3 4 1 Set Minimum ON Time to 4 minutes 2 Set Cycle Hour to 3 Thermal Actuator 12 1 Set Cycle Hour to 12 Zone valve 6 1 No action required Special Features Description System Type When bound to a 2 channel receiver box the system type can be set Hea...

Page 5: ...ted in a hot cold location and cannot be moved because of wiring then the measured displayed temperature can be adjusted by 1 5 oC This feature is useful if the homeowner wants the reading to match another appliance temperature display Binding Menu to bind the Thermostat and the Receiver box test the RF signal strength of the radio communication and to clear an existing binding Reset Menu to reset...

Page 6: ...T6RWP THERMOSTAT PACKAGING ACC900 IN WALL POWER MODULE 6 ...

Page 7: ...ld not be placed near draughts in direct sunlight or near heat sources It should be at least 1 2 1 5 meters from the floor Needed during installation Wall box with minimum depth of 40 mm and with 230V cabling neutral and line An installed Receiver Box single or 2 channel version C Wall plate Using a screwdriver open wall plate terminal cover to connect wires B Power module Connect the 230V power w...

Page 8: ...row Now bind with the Receiver box Press the big button on the Receiver Box for 3 seconds Press to bind the thermostat to the Receiver Box When binding is successful Thermostat will show SUCCESS First Receiver box status LED will show green Press to continue the set up When bound to a 2 channel Receiver box the system type can be selected Press to set up system type Touch to finalise setup to setu...

Page 9: ...ct BIND and the signal will be sent 5 When binding is successful Thermostat will show SUCCESS First Receiver box status LED will show green Note When the Receiver box has been bound before first press with a small pin the pinhole for approximately 3 seconds to reset the binding All LED s will flash amber for a moment When binding is NOT successful Thermostat will show FAILED Receiver box will exit...

Page 10: ...o communication from the thermostat RF signal is blocked due to the location of the thermostat Receiver box is no longer powered RF communication might be too far or is blocked due to the location of the Thermostat or Receiver box Check the power to the Receiver box RF SIGNAL OFRECEIVER BOX LOW There is a weak radio signal from the Receiver box Try to move thermostat or Receiver box closer or re l...

Reviews: