EN
EN1H-1375GE23 R1020 - Translation of original
11
Resideo Technologies
4.1 Construction dimensions
DN1
88
±10
DN100
DN2
175
30
L2
±10
L
max ±10
800
Type
CBU145-50A-042
CBU145-50A-052
CBU145-50A-063
CBU145-50A-074
CBU145-50A-085
CBU145-50A-095
CBU145-50A-105
CBU145-65A-128
CBU145-80B-052
CBU145-80B-063
CBU145-80B-073
CBU145-80B-084
CBU145-80B-094
CBU145-80B-104
CBU145-80B-114
CBU145-80B-125
DN1
G2"
G2"
G2"
G2"
G2"
G2"
G2"
G2"
G2 1/2"
G2 1/2"
G2 1/2"
G2 1/2"
G2 1/2"
G2 1/2"
G2 1/2"
G2 1/2"
DN2
DN50
DN50
DN50
DN50
DN50
DN50
DN50
DN65
DN80
DN80
DN80
DN80
DN80
DN80
DN80
DN80
H
1
1372
1372
1372
1372
1372
1372
1372
1372
1425
1425
1425
1425
1425
1425
1425
1425
H
2
208
208
208
208
208
208
208
223
257
257
257
257
257
257
257
257
L
2
1720
1720
1720
1720
1720
1720
1720
1860
1885
1885
1885
1885
1885
1885
1885
1885
L
max
2000
2000
2000
2000
2000
2000
2000
2000
2095
2135
2135
2135
2135
2135
2135
2135
Weight [kg]
404
506
508
518
523
691
693
773
665
666
675
703
748
778
783
855
All dimensions in mm unless stated otherwise.
4.2
Noise expectancy values
Refer to pump manual for noise value of the pump.
4.3
Authorised environmental conditions
Ambient temperature
5°C ...40°C
Relative air humidity
max. 80% r.h.
H2
±5
587
±5
H1
1712