background image

RESI® 

  

Titel: 

Manual RESI-DALI-ASCII

 

Datum 

Seite 

Von 

14.02.2015 

24 

89 

 

.

P

ro

p

ri

e

ta

ry

 

 

 d

a

ta

 

 

co

m

p

a

n

  

co

n

fid

e

n

ti

a

l. 

 

 

 A

ll 

 r

ig

h

ts

 

  

re

s

e

rv

e

d

.

C

o

n

fié

 

  

à

 

  

tit

re

 

 

d

e

  

se

c

re

  

d

'e

n

tr

e

p

ri

s

e

 T

o

u

 d

ro

its

 

 

 r

é

se

rv

é

s

.

C

o

m

u

n

ic

a

d

o

 c

o

m

o

 

se

g

re

d

o

 e

m

p

re

sa

ri

a

l. 

R

e

se

rv

a

d

o

to

d

o

o

 

d

ir

e

ito

s.

C

o

n

fid

a

d

o

 

co

m

o

 s

e

cr

e

to

 i

n

d

u

s

tr

ia

l. 

N

o

re

s

e

rv

a

m

o

s

 t

o

d

o

s

 l

o

s

 d

e

re

c

h

o

s

.

 

 

.

W

e

it

e

rg

a

b

e

 

 

s

o

w

ie

 

 

V

e

r

v

ie

lf

ä

lt

ig

u

n

g

 

 

d

ie

s

e

U

n

te

rl

a

g

e

 

 

V

e

r-

w

e

rt

u

n

g

 

 

u

n

d

 

 

M

it

te

ilu

n

g

 

 

ih

re

s

 

In

h

a

lt

s

 

n

ic

h

g

e

s

ta

tt

e

t,

 

s

o

w

e

it

n

ic

h

 

a

u

s

d

r

ü

c

k

lic

h

 

 

z

u

g

e

s

ta

n

d

e

n

 

 

Z

u

w

id

e

rh

a

n

d

lu

n

g

e

n

 

 

v

e

r-

p

fl

ic

h

te

n

 

z

u

 

S

c

h

a

d

e

n

e

rs

a

tz

 

 

A

ll

e

 

R

e

c

h

te

 

v

o

rb

e

h

a

lt

e

n

in

s

b

e

-

s

o

n

d

e

re

 

d

e

n

 

F

a

ll 

d

e

P

a

te

n

te

rt

e

il

u

n

g

 

o

d

e

G

M

-E

in

tr

a

g

u

n

g

.

.

7.15 

Dim down a lamp group 

This command dims down a group of lamps a little bit with the DALI command DOWN. It is very important, that 
the lamps have to be on, before you send this command. Otherwise this command is ignored by the lamp. Each 
lamp can be dimmed down to their minimum brightness value, but they will not be switched off by this command. 
The DALI standard supports 16 DALI lamp groups. 
 
Host long version: 
#GROUP<SP>DOWN:<GROUP><CR> or 
#<ADR>,GROUP<SP>DOWN:<GROUP><CR> 
 
Host short version: 
#GDO:<GROUP><CR> or #<ADR>,GDO:<GROUP><CR> 
 
Answer: 
If everything was ok with the command, the converter answers with  
#OK<CR> or #<ADR>,OK<CR> 
 
If the DALI bus has no power, the converter answers with 
#ERR:DALI<SP>BUS<SP>ERROR<CR> or #<ADR>,ERR:DALI<SP>BUS<SP>ERROR<CR> 
 
If there is a syntax problem with the command, the converter answers with  
#ERR:SYNTAX<SP>ERROR<CR> or #<ADR>,ERR:SYNTAX<SP>ERROR<CR> 
 
<GROUP> defines the affected DALI group according to the DALI standard.  Group numbers from 0 to 15 are 
allowed. 
 
Samples: 
Dim down group 4: 

 #GROUP

DOWN:4

CR

 

 #OK

CR 

 

 #255,GDO:0x04

CR

 

 #255,OK

CR 

 
Dim down group 32: 

 #GROUP

DOWN:32

CR

 

 #OK

CR 

 

 #255,GDO:0x20

CR

 

 #255,OK

CR 

7.16 

Dim down a single lamp 

This command dims down a single lamp a little bit with the DALI command DOWN. It is very important, that the 
lamp has to be on, before you send this command. Otherwise this command is ignored by the lamp. Each lamp 
can be dimmed down to their minimum brightness value, but it will not be switched off by this command. The 
DALI standard supports 64 DALI lamps. 
 
Host long version: 
#LAMP<SP>DOWN:<LAMP><CR> or 
#<ADR>,LAMP<SP>DOWN:<LAMP><CR> 
 
Host short version: 
#LDO:<LAMP><CR> or #<ADR>,LDO:<LAMP><CR> 
 
Answer: 
If everything was ok with the command, the converter answers with  
#OK<CR> or #<ADR>,OK<CR> 
 
If the DALI bus has no power, the converter answers with 
#ERR:DALI<SP>BUS<SP>ERROR<CR> or #<ADR>,ERR:DALI<SP>BUS<SP>ERROR<CR> 
 
If there is a syntax problem with the command, the converter answers with  

Summary of Contents for RESI-DALI-ASCII

Page 1: ...ASCII RESI DALI PS Great care has been taken in the creation of the text illustrations and program examples in this manual RESI Informatik Automation GmbH company the editors and publishers accept no...

Page 2: ...os direitos Confidado como secreto industrial Nos reservamos todos los derechos Weitergabe sowie Ver vielf ltigung dieser Unterlage Ver wertung und Mitteilung ihres Inhalts nicht gestattet soweit nich...

Page 3: ...7 15 DIM DOWN A LAMP GROUP 24 7 16 DIM DOWN A SINGLE LAMP 24 7 17 SWITCH ON AND DIM UP ALL LAMPS 25 7 18 SWITCH ON AND DIM UP A GROUP OF LAMPS 25 7 19 SWITCH ON AND DIM UP A SINGLE LAMP 26 7 20 DIM D...

Page 4: ...COMMAND IN A GROUP OF LAMPS 54 7 70 DO STORE DTR AS POWER ON LEVEL COMMAND IN A SINGLE LAMP 55 7 71 DO STORE DTR AS FADE TIME COMMAND IN ALL LAMPS 55 7 72 DO STORE DTR AS FADE TIME COMMAND IN A GROUP...

Page 5: ...Inhalts nicht gestattet soweit nicht ausdr cklich zugestanden Zuwiderhandlungen ver pflichten zu Schadenersatz Alle Rechte vorbehalten insbe sondere f r den Fall der Patenterteilung oder GM Eintragun...

Page 6: ...e technical specifications and tolerances given in the technical manuals for the product If you do not obey this issue the proper performance of the device cannot be guaranteed This can lead to fail f...

Page 7: ...n Zuwiderhandlungen ver pflichten zu Schadenersatz Alle Rechte vorbehalten insbe sondere f r den Fall der Patenterteilung oder GM Eintragung Our devices must not be used for monitoring applications wh...

Page 8: ...need an intelligent unit with a build in serial interface RS232 or RS485 The unit must be able to send and receive ASCII text messages This is available in almost every media control system like CREST...

Page 9: ...x 90mm x 58mm Weight RESI DALI MODBUS 55g RESI DALI PS 65g Mounting on DIN EN50022 rail only RESI DALI ASCII ASCII Modbus Interface Factory settings Protocol ASCII or Modbus RTU ASCII Modbus address...

Page 10: ...lich zugestanden Zuwiderhandlungen ver pflichten zu Schadenersatz Alle Rechte vorbehalten insbe sondere f r den Fall der Patenterteilung oder GM Eintragung 5 Mounting and Connections 5 1 Assembling Ou...

Page 11: ...m the DIN rail first open the clamp lever with a screwdriver on the bottom side 4 Hold the clamp lever opened while you lift the module from the DIN rail 5 Then remove the converter from the bar with...

Page 12: ...cklich zugestanden Zuwiderhandlungen ver pflichten zu Schadenersatz Alle Rechte vorbehalten insbe sondere f r den Fall der Patenterteilung oder GM Eintragung RESI DALI PS L M Power supply L 24 V M Gro...

Page 13: ...ation Description of the DIP switch settings and LED status displays DIP Switch Description Baudrate BR Use DIP Switches 1 2 to select baud rate OFF OFF 9600Bd ON OFF 19200Bd OFF ON 38400Bd ON ON 5760...

Page 14: ...rvamos todos los derechos Weitergabe sowie Ver vielf ltigung dieser Unterlage Ver wertung und Mitteilung ihres Inhalts nicht gestattet soweit nicht ausdr cklich zugestanden Zuwiderhandlungen ver pflic...

Page 15: ...propriate standards see EN60929 For the communication via ASCII text strings all ASCII messages start with a special character 0x23 35dec and end with the special character CARRIAGE RETURN 0x0d 13dec...

Page 16: ...allowed as hexadecimal numbers All converters on the bus react to the broadcast bus number 0 and to its own configured bus number With an external DIP switch you can switch very fast between the fixe...

Page 17: ...or ADR VER CR Answer VERSION HIGH MED LOW CR or ADR VERSION HIGH MED LOW CR HIGH MED LOW describe the current software version e g 3 0 0 Samples VERSIONCR VERSION 3 0 0CR With broadcast address in dec...

Page 18: ...answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP ERROR CR LEVEL represents the new brightness value according to the DALI standard You can use brightness levels between 0 0 and 254 100 255 is...

Page 19: ...n LAMP SP LEVEL LAMP LEVEL CR or ADR LAMP SP LEVEL LAMP LEVEL CR Host short version LL LAMP LEVEL CR or ADR LL LAMP LEVEL CR Answer If everything was ok with the command the converter answers with OK...

Page 20: ...is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP ERROR CR Samples Switch off all lamps ALL OFFCR OKCR 255 AOFCR 255 OKCR 7 9 Switch off all l...

Page 21: ...ter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP ERR...

Page 22: ...UP GROUP CR or ADR GROUP SP UP GROUP CR Host short version GUP GROUP CR or ADR GUP GROUP CR Answer If everything was ok with the command the converter answers with OK CR or ADR OK CR If the DALI bus...

Page 23: ...the affected short address of the lamp according to the DALI standard The short address range 0 to 63 is allowed Samples Dim up lamp 47 LAMP UP 47CR OKCR 255 LUP 0x2FCR 255 OKCR Dim up lamp 58 LAMP UP...

Page 24: ...was ok with the command the converter answers with OK CR or ADR OK CR If the DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there i...

Page 25: ...STEP UP If the lamps are off this commands switches on the lamps first Each lamp can be dimmed up to their maximum brightness value Host long version ALL SP ON SP AND SP STEP SP UP CR or ADR ALL ON SP...

Page 26: ...p 4 GROUP ON AND STEP UP 4CR OKCR 255 GOSUP 0x04CR 255 OKCR Switch on and dim up group 32 GROUP ON AND STEP UP 32CR OKCR 255 GOSUP 0x20CR 255 OKCR 7 19 Switch on and dim up a single lamp This command...

Page 27: ...DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP E...

Page 28: ...a little bit with the DALI command STEP DOWN AND OFF If the lamp dim below its current minimum brightness this commands switches off the lamp The DALI standard supports 64 lamps Host long version LAM...

Page 29: ...ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP ERROR CR Samples Di...

Page 30: ...r If everything was ok with the command the converter answers with OK CR or ADR OK CR If the DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERRO...

Page 31: ...version GROUP SP STEP SP DOWN GROUP CR or ADR GROUP SP STEP SP DOWN GROUP CR Host short version GSDO GROUP CR or ADR GSDO GROUP CR Answer If everything was ok with the command the converter answers w...

Page 32: ...R 255 OKCR Dim down immediately lamp 58 LAMP STEP DOWN 58CR OKCR 255 LSDO 0x3ACR 255 OKCR 7 29 Recall maximum level in all lamps This command sends the DALI command RECALL MAXIMUM LEVEL to all DALI la...

Page 33: ...ected DALI group according to the DALI standard Group numbers from 0 to 15 are allowed Samples Recall maximum level in group 4 GROUP RECALL MAX LEVEL 4CR OKCR 255 GRMAXL 0x04CR 255 OKCR Recall maximum...

Page 34: ...ARMINL CR or ADR ARMINL CR Answer If everything was ok with the command the converter answers with OK CR or ADR OK CR If the DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR...

Page 35: ...OKCR 7 34 Recall minimum level in a single lamp This command sends the DALI command RECALL MINIMUM LEVEL to a single DALI lamp The affected lamp dim down to its individual stored minimum brightness va...

Page 36: ...converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX...

Page 37: ...e answer of the lamp is returned as a number The DALI standard supports 64 lamps Host long version LAMP SP COMMAND SP ANSWER LAMP COMMAND CR or ADR LAMP SP COMMAND SP ANSWER LAMP COMMAND CR Host short...

Page 38: ...the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYN...

Page 39: ...single lamp This command sends a DALI command to a single lamp twice within 100ms The answer of the lamp is returned as a number The DALI standard supports 64 lamps Host long version LAMP SP COMMAND...

Page 40: ...P ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP ERROR CR COMMAND defines a valid 8 bi...

Page 41: ...no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or A...

Page 42: ...erter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP E...

Page 43: ...e command the converter answers with OK CR or ADR OK CR If the DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax prob...

Page 44: ...tness value Arc power for a single lamp The DALI standard supports 64 lamps Host long version LAMP SP ARC SP POWER LAMP ARCPOWER CR or ADR LAMP SP ARC SP POWER LAMP ARCPOWER CR Host short version LARC...

Page 45: ...GOTO SCENE 15CR OKCR 255 AGS 0x0FCR 255 OKCR 7 51 Recall scene in a group of lamps This command recalls a previous stored scene in a group of lamps The DALI standard supports 16 lamp groups and 16 DA...

Page 46: ...rs with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP ERROR CR LAMP represents the affected short address of the lamp according to the DALI standard The short address range 0 to 63 is allowed SCENE defi...

Page 47: ...ith the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP ERROR CR GROUP defines the affected DALI group according to the DALI standard Group numbers from 0 to 15 are allo...

Page 48: ...R or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP ERROR CR Samples Do STORE ACTUAL LEVEL IN DTR...

Page 49: ...R or ADR OK CR If the DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answer...

Page 50: ...answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR SYNTAX SP ERROR...

Page 51: ...rter answers with OK CR or ADR OK CR If the DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the comman...

Page 52: ...SDMINL LAMP CR or ADR LSDMINL LAMP CR Answer If everything was ok with the command the converter answers with OK CR or ADR OK CR If the DALI bus has no power the converter answers with ERR DALI SP BUS...

Page 53: ...DTR SP AS SP SYSTEM SP FAILURE SP LEVEL GROUP CR Host short version GSDSFL GROUP CR or ADR GSDSFL GROUP CR Answer If everything was ok with the command the converter answers with OK CR or ADR OK CR If...

Page 54: ...OWER ON LEVEL to all lamps twice within 100ms Host long version ALL SP STORE SP DTR SP AS SP POWER SP ON SP LEVEL CR or ADR ALL SP STORE SP DTR SP AS SP POWER SP ON SP LEVEL CR Host short version ASDP...

Page 55: ...DTR AS POWER ON LEVEL to a single lamp twice within 100ms The DALI standard supports 64 lamps Host long version LAMP SP STORE SP DTR SP AS SP POWER SP ON SP LEVEL LAMP CR or ADR LAMP SP STORE SP DTR...

Page 56: ...the DALI command STORE DTR AS FADE TIME to a group of lamps twice within 100ms The DALI standard supports 16 lamp groups Host long version GROUP SP STORE SP DTR SP AS SP FADE SP TIME GROUP CR or ADR...

Page 57: ...to 63 is allowed Samples Do STORE DTR AS FADE TIME in lamp 47 LAMP STORE DTR AS FADE TIME 47CR OKCR 255 LSDFT 0x2FCR 255 OKCR 7 74 Do STORE DTR AS FADE RATE command in all lamps This command send the...

Page 58: ...RATE in lamp group 4 GROUP STORE DTR AS FADE RATE 4CR OKCR 255 GSDFR 0x04CR 255 OKCR 7 76 Do STORE DTR AS FADE RATE command in a single lamp This command send the DALI command STORE DTR AS FADE RATE...

Page 59: ...stored as brightness value Valid is 0 to 15 for the 16 possible scenes Samples Do STORE DTR AS SCENE 12 in all lamps ALL STORE DTR AS SCENE 12CR OKCR 255 ASDS 0xCCR 255 OKCR 7 78 Do STORE DTR AS SCENE...

Page 60: ...er the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTAX SP ERROR CR or ADR ERR...

Page 61: ...f the DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the converter answers with ERR SYNTA...

Page 62: ...X CR or ADR OK BYTES RESULTDEC RESULTHEX CR If there is no valid answer within 1 second on the DALI bus the converter answers with OK 9 99 0x63 CR or ADR OK 9 99 0x63 CR If the DALI bus has no power t...

Page 63: ...CR or ADR OK 9 99 0x63 CR If the DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the command the conv...

Page 64: ...s sends no answer and the result will be a timeout 9 99 0x63 255 LQLF 0x2FCR 255 OK 1 255 0xFFCR 7 86 Do QUERY LAMP POWER ON in a single lamp This command checks with the DALI command QUERY LAMP POWER...

Page 65: ...or ADR OK BYTES RESULTDEC RESULTHEX CR If there is no valid answer within 1 second on the DALI bus the converter answers with OK 9 99 0x63 CR or ADR OK 9 99 0x63 CR If the DALI bus has no power the c...

Page 66: ...LTHEX is the 8 bit answer value of the DALI bus as hexadecimal number Samples Do QUERY RESET STATE in lamp 47 LAMP QUERY RESET STATE 47CR OK 1 255 0xFFCR The return value of 255 0xFF means YES the lam...

Page 67: ...T LAMP CR or ADR LQDT LAMP CR Answer If everything was ok with the command the converter answers with OK BYTES RESULTDEC RESULTHEX CR or ADR OK BYTES RESULTDEC RESULTHEX CR If there is no valid answer...

Page 68: ...address range 0 to 63 is allowed RESULTDEC is the 8 bit answer value of the DALI bus as decimal number RESULTHEX is the 8 bit answer value of the DALI bus as hexadecimal number Samples Do QUERY CONTE...

Page 69: ...CONTENT SP DTR2 LAMP CR or ADR LAMP SP QUERY SP CONTENT SP DTR2 LAMP CR Host short version LQCD2 LAMP CR or ADR LQCD2 LAMP CR Answer If everything was ok with the command the converter answers with OK...

Page 70: ...RR SYNTAX SP ERROR CR LAMP represents the affected short address of the lamp according to the DALI standard The short address range 0 to 63 is allowed RESULTDEC is the 8 bit answer value of the DALI b...

Page 71: ...CR 255 OK 1 85 0x55CR 7 96 Do QUERY MAXIMUM LEVEL in a single lamp This command reads out with the DALI command QUERY MAXIMUM LEVEL the brightness level which is used by the lamp as a maximum brightne...

Page 72: ...th OK 9 99 0x63 CR or ADR OK 9 99 0x63 CR If the DALI bus has no power the converter answers with ERR DALI SP BUS SP ERROR CR or ADR ERR DALI SP BUS SP ERROR CR If there is a syntax problem with the c...

Page 73: ...rn value represents a brightness value between 0 and 254 This brightness level is used in case of a power on by the lamp If there is no lamp on the DALI bus the return value will be 9 99 0x63 Timeout...

Page 74: ...everything was ok with the command the converter answers with OK BYTES RESULTDEC RESULTHEX CR or ADR OK BYTES RESULTDEC RESULTHEX CR If there is no valid answer within 1 second on the DALI bus the con...

Page 75: ...the 8 bit answer value of the DALI bus as hexadecimal number Samples Do QUERY FADE TIME FADE RATE in lamp 47 LAMP QUERY FADE TIME FFADE RATE 47CR OK 1 7 0x7CR The return value is an 8 bit value repres...

Page 76: ...ALI command QUERY GROUPS 0 7 the current participation to the groups 0 to 7 for the selected lamp The DALI standard supports 64 lamps Host long version LAMP SP QUERY SP GROUPS SP 0 7 LAMP CR or ADR LA...

Page 77: ...erter answers with OK BYTES RESULTDEC RESULTHEX CR or ADR OK BYTES RESULTDEC RESULTHEX CR If there is no valid answer within 1 second on the DALI bus the converter answers with OK 9 99 0x63 CR or ADR...

Page 78: ...iderhandlungen ver pflichten zu Schadenersatz Alle Rechte vorbehalten insbe sondere f r den Fall der Patenterteilung oder GM Eintragung 8 MODBUS register description 8 1 Overview Register Group Functi...

Page 79: ...erhandlungen ver pflichten zu Schadenersatz Alle Rechte vorbehalten insbe sondere f r den Fall der Patenterteilung oder GM Eintragung 8 2 MODBUS Register Be aware that this manual indexes the MODBUS r...

Page 80: ...he standard norm DALI lamps accept 254 0xFEh as upper threshold fort he brightness value Therefore the value 255 0xFFh will be ignored and designated as threshold error For more detailed information p...

Page 81: ...ording to the standard norm DALI lamps accept 254 0xFEh as upper threshold fort he brightness value Therefore the value 255 0xFFh will be ignored and designated as threshold error For more detailed in...

Page 82: ...Note According to the standard norm DALI lamps accept 254 0xFEh as upper threshold fort he brightness value Therefore the value 255 0xFFh will be ignored and designated as threshold error For more det...

Page 83: ...register Then send the INITIALIZE command Write 0xA500 to this register 4x00543 because the command hast to be transmitted twice within 100ms Now send START PHSICAL SELECTON command Write 0xBD00 to th...

Page 84: ...s register The status register indicates the status of the DALI bus Under normal conditions this MODBUS register is not used read only holding register 4x00551 factory settings 15 14 13 12 11 10 9 8 7...

Page 85: ...abe sowie Ver vielf ltigung dieser Unterlage Ver wertung und Mitteilung ihres Inhalts nicht gestattet soweit nicht ausdr cklich zugestanden Zuwiderhandlungen ver pflichten zu Schadenersatz Alle Rechte...

Page 86: ...nterteilung oder GM Eintragung 8 2 10 MODBUS address READ WRITE holding register 4x65222 factory settings 255 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MODBUSADR bit description MODBUSADR Modbus address d...

Page 87: ...Ver vielf ltigung dieser Unterlage Ver wertung und Mitteilung ihres Inhalts nicht gestattet soweit nicht ausdr cklich zugestanden Zuwiderhandlungen ver pflichten zu Schadenersatz Alle Rechte vorbehal...

Page 88: ...ighter If the lamp was switched off it stays switched off 4 0x04h STEP DOWN Lamp switches one step darker As soon as the lower brightness threshold level is reached the lamp stays at this value 5 0x05...

Page 89: ...ores the actual register value DTR as fade time for lamp 47 0x2Fh STORE DTR AS FADE RATE Stores the actual register value DTR as fade rate for lamp 64 79 0x40h 0x4F STORE DTR AS SCENE Stores the actua...

Reviews: