3.

Attach Gauge to Valve.

4.

Press Repressurize Button and wait unit the Gauge reads 0 MPa.

5.

Remove Gauge and attach Plug.

6.

To remove LCD Port or LCD Port Cover, while pressing LCD Port Lock Button turn 

LCD Port or LCD Port Cover counterclockwise until it stops. Carefully remove from 

Housing Port.

7.

Open back cover. Refer to INSTALLING CAMERA IN HOUSING, 3.

8.

Unplug SONY RM-VPR1 Remote Commander Cable from camera and remote.

9.

Carefully remove camera from housing.

CAUTION!  

Neglecting to wash salt and other contaminants from the housing may result in 

damage the housing raising the risk of leakage during future use.

 Damages due to the lack of 

proper cleaning and maintenance is not covered under warranty.

ARMS & LIGHTS INSTALLATION

The housing is equipped with two (2) M10/P1Ball Joint Base sockets and comes with a dual 

grip and tray assembly which can be attached using two (2) tripod screw sockets located at 

the bottom of the main body. Please use as needed.

CAUTION! 

Use the grip and tray assemblies provided. 

Leakage or damage due to the use of 

other than assembly provided is NOT covered under warranty.

MAINTENANCE

CAUTION! 

Allowing saltwater and contaminants to dry on housing can damage functions and 

O-rings possibly causing water leakage. Clean with fresh water only, using a soft, dry cloth to 

wipe away water.

1. After   extended   periods   of   non-use,   soak   empty   housing,   making   sure   back   cover   is 

properly attached, in lukewarm for half a day. Manipulate all buttons and dials several 

times. Using a soft, dry cloth wipe away water. 

After use in salt water, wash off salt and other contaminants by soaking empty housing, 

back cover is properly attached, thoroughly in a bucket of fresh water (lukewarm) for 10 to 

20 minutes. Manipulate all buttons and dials several times. Using a soft, dry cloth wipe 

away water.

2. Remove Back Cover, LCD Port or LCD Port Cover and using the O-ring Removal Pick, 

remove the O-rings.

3. Perform O-RING GREASING & MAINTENANCE as instructed below before re-installing.

O-RING GREASING & MAINTENANCE ( 1)

CAUTION!

 DO NOT use silicone grease other than that provided by Seatool/Recsea.

1. Using the O-ring Removal Pick, remove Back Cover and LCD Port or LCD Port Cover O-

rings.

2. Clean sand, salt, other contaminants and old grease from O-rings.

3. Clean O-ring grooves and O-ring contact surfaces using a clean cotton swab.

4. Visually and physically check  each O-ring by running it through finger tips, feeling for 

cuts, cracks or any other defects that may cause leakage. Such defects will cause water 

leakage, so be sure to replace defective O-rings. Be careful not to stretch or pull the O-

rings too much.

5. Squeeze a rice grain sized bead of silicone grease on your thumb and forefinger. Taking 

care not to pull or stretch the O-ring too much, uniformly spread grease on each O-ring. 

Too little  grease  may cause   an O-ring  to twist   in the  groove,  possibly causing  water 

leakage.

13

Summary of Contents for RVH-AXP35-LCD

Page 1: ...SONY FDR AX30 AX33 AXP33 AXP35 4K Camcorders Waterproof Housings Recsea RVH AXP35 LCD RVH AXP35 VF MANUAL Please read this manual before use NTF CORPORATION UH Division http www seatool net...

Page 2: ...emble or modify this housing Do not store the housing in areas of high humidity high or low temperatures or areas of extreme temperature fluctuation Doing so may cause deterioration of parts When divi...

Page 3: ...Two 2 M10 Ball Joint Sockets Quality silicone Back Cover O ring with wide Back Cover contact surface Variety of supported RECSEA original options PACKAGE CONTENTS Be sure all items listed here were in...

Page 4: ...RVH AXP35 LCD RVH AXP35 LCD RVH AXP35 LCD RVH AXP35 VF 3...

Page 5: ...RVH AXP35 LCD RVH AXP35 VF Viewfinder For use with camera s viewfinder Can easily be replaced with optional INON 45 Viewfinder Unit witout the need of an adapter 4...

Page 6: ...N and OFF REC Button Press the REC Button to START recording Press the REC Button again to STOP recording Photo Button Half press the Photo Button to bring the image into focus and then press the butt...

Page 7: ...f the housing using a soft dry cloth In the unlikely event water sucked inside please remove with a clean dry cloth When opening housing or conducting maintenance please do so in a clean place with lo...

Page 8: ...atches 2 away from the back cover 4 a RVH AXP35 LCD With housing LCD Port removed and camera LCD open set camera Camera Tray attached into position as shown below taking care to line up the Camera Tra...

Page 9: ...ng camera take care that camera s Grip Belt does not cause an obstruction With RVH AXP35 VF be sure to extend camera s viewfinder If this is not done the camera will not be turned ON when using the Re...

Page 10: ...n both sides making sure the latch on the underside is properly placed in the Secure Latch Groove 1 on both sides of the back cover Push into the locked position Double check to make sure both Secure...

Page 11: ...TALLING LCD PORT COVER RVH AXP35 VF Please conduct the following operations in a clean area with low humidity and dust Please perform proper LCD Port Cover O ring and housing port contact surface main...

Page 12: ...ng water use a method of water entry that protects the housing from shock which can cause water leakage If at all possible have Housing handed to you after entering the water After use in salt water w...

Page 13: ...he housing is air and water tight b If there is pressure change there is the possibility of a leak Check housing and try again 7 Pull Valve Sleeve downward to release Gauge 8 Insert Plug into the Valv...

Page 14: ...of non use soak empty housing making sure back cover is properly attached in lukewarm for half a day Manipulate all buttons and dials several times Using a soft dry cloth wipe away water After use in...

Page 15: ...tenance and greasing every time you open or close the housing Please pay close attention and make sure the O ring is not twisted or bulging free of any contaminants dirt hair etc and that foreign obje...

Page 16: ...customer use and for any consumable parts the repairs will be charged at normal rates Shipping costs to and from dealer or Japan if necessary shall be born by the customer for warranty and all other...

Page 17: ...MEMO...

Page 18: ...MEMO...

Page 19: ...MEMO...

Page 20: ...Number RVH AXP35 LCD RVH AXP35 VF Dealer Name Serial Number Dealer Stamp your company name and contact information purchase date model and serial number Seatool Recsea Manufacturing Sales NTF CORPORA...

Reviews: