background image

Trademarks:

 

All trade names and trademarks are the properties of their respective companies.

 

 

Copyright © 2022, All Rights Reserved.

 

 

 

User Manual

 

Industrial Gigabit PoE Media Converter, 

 

with 1 x 10/100/1000M TX 30W PSE + 1 x 100/1000M SFP, 48-56 VDC input

 

 

FCC MARKING

 

 

This Equipment has been tested and found to comply with the limits for a Class A digital device, 
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against  harmful      interference      when      the      equipment      is      operated      in      a  commercial 
environment. This equipment generates, uses, and can radiate radio frequency energy and, if 
not  installed  and  used  in  accordance  with  the  instruction  manual,  may  cause  harmful 
interference to radio communications.

 

Operation of this equipment in a residential area is likely to cause harmful interference in which 
case the user will be required to correct the interference at his own expense.

 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) this device may not cause harmful interference, and (2) this device must accept 
any interference received; including interference that may cause undesired operation.

 

 

CE MARKING

 

 

This equipment complies with the requirements relating to electromagnetic compatibility, EN 
55032/35 class A for ITE, the essential protection requirement of Council Directive 2014/30/EC 
on the approximation of the laws of the Member States relating to electromagnetic compatibility.

 

Company  has  an  on-going  policy  of  upgrading  its  products  and  it  may  be  possible  that 
information in this document is not up-to-date. Please check with your local distributors for the 
latest information. No part of this document can be copied or reproduced in any form without 
written consent from the company.

 

 
 
 

 

Summary of Contents for RP-IMC811FP

Page 1: ...likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CE MARKIN...

Page 2: ... environment 40 C to 75 C Introduction This Rugged Industrial PoE Media Converter is designed with hardened Marvell IC delivering 30Watts of PoE power to your PD while tolerating extreme temperatures in a harsh environment Our Cold Design technology will not only power up your PD device but also reduce the excessive heat problem to a minimum It accepts input voltages from 48VDC to 56VDC to meet IE...

Page 3: ...e wire to V connect negative wire to V and connect neutral wire to ground V is for power input connection this unit has only one power input RLY is for relay connection Power connecting procedure STEP 1 Take out 4 pin terminal block located in the included mounting kit package STEP 2 Connect power wire to V with correct polarity and connect RLY for relay Connect the grounding wire to the ground sc...

Page 4: ... as SFP speed 1000M The table shown as you may change the dip switch setting to your desired environment LED indicator PWR Green ON Power is detected OFF Power is not detected SFP Lnk Act Green ON FX port is detected Flashing FX data is transmitting receiving Lnk Green ON TX link is detected Flashing TX data is transmitting receiving PoE Amber ON PD is detected on designated port OFF no PD is dete...

Page 5: ...Cat 5e Cable EIA TIA 568 10 ohm 100m Protocol CSMA CD LED PWR Green ON Power is detected OFF Power is not detected SFP Lnk Act Green ON FX port is detected Flashing FX data is transmitting receiving RJ 45 port Lnk Act Green ON TX port is detected Flashing TX data is transmitting PoE Amber ON PD is detected on designated port OFF no PD is detected PoE Pin Assignment 30 watts 2 pairs Mode A End Span...

Page 6: ...Torque 5lb In 0 5Nm 0 56Nm Wire Strip length 7 8mm Operating Temperature 40 to 75 Operating Humidity 5 to 95 Non condensing Storage Temperature 40 to 85 MTBF mean time between failure 510 304 hrs MIL HDBK 217F at 25 C Housing Rugged Metal IP30 Protection Case Dimension L X W X D mm 103 5mmx32mmx81 5mm LxWxD Installation mounting DIN Rail and Wall Mount options included Certifications Safety UL 609...

Page 7: ...ng Dimension mm NOTE Housing dimension is for purpose of showing product Length Width Height din rail and terminal block s position and dimension Please reference the LED Indicator Page for correct port order ...