Connection
Via separately connected electricity supply
Separate 2-pin residual current
circuit breaker mandatory:
RCD with I
Δ
N ≤ 30 mA (overvoltage category III)
Supply voltage
230 V AC, 50 Hz
Fuse without
16 A-B for 3 x 1.5 mm² supply line
supplementary heating
Connected load
1.3 kW
13 TECHNICAL DATA
Servicing / technical data
12 TROUBLESHOOTING TECHNICAL PROBLEMS
PROBLEM
1. No display on control panel
2.
Key flashes when pressed
and fan starts
3. Key double flashes
during/after draining.
4. Both pump and
fan switch off
automatically.
5. Irregular water pump
suction. Fluctuating
water nozzle output
SOLUTION
- Check the electricity supply
- Not enough water in the bath
- Fill up the bath to approx. 5-8 cm above the top nozzles
- Automatic blow-out active, fan starts after
timer period.
- The system switches off automatically after around
20 min. via a timer. You can then reactivate it
immediately.
- Not enough water/water loss (see 2.)
- Drain outlet is blocked/drain plug is incorrectly positioned.
Tighten the adjustment screws by approx. 2-3 mm.
- Adjust at the plug (see section 11)
- Remove the drain cover (4) together with the drain plug (5)
by lifting it upwards
Attention:
The plug is only loosely fitted, it can
fall out and damage the bath
- Clean the filter (6)
- You can adjust the drain plug using the adjustment screw (7)
4
5
7
6
11
CLEANING THE DRAIN FILTER,
ADJUSTING THE DRAIN PLUG