4.6 Electrical connection
Figure 5
Nr.
Description
1
Connection plug for signal lamp
(Mounted on delivery)
The supply line is inserted from below
through the cable gland. The wires are to
be clamped directly onto the terminal block.
The PE connection is made at the green -
yellow terminal.
The neutral conductor must be connected
to the blue terminal.
2
Enable contact X4
-
GND
IN
Digital Input
+
+24V-DC
Bridge between "+" and "IN"
Charging enable
active.
When using the RFID reader, the enable contact
cannot be used because the RFID reader is
connected to this contact.
-
Orange
IN Red
+
Brown
3
Mains connection
1-phase: L1, N, PE
3-phase: L1, L2, L3, N, PE
4
Cable gland
Connection cable
5
Connector plug
(Mounted on delivery.)
Fault current circuit breaker ready mounted