Hardware
7
Doc No: UMAN\GWY-500-B\0106
REVISION 4
2.2
Communication Port Details
GWY-500 has two communication ports COM1 and COM2. COM1 port is compactible to RS232/ RS422/ RS485 and
CMOS signal levels. Pinout of this port is given as follows:
TX- (RS422/RS485)
DB9 Female
1
5
9
6
+5VDC*
(DO NOT USE)
Signal Ground
RX+ (RS422/RS485)
RXD (RS232C/CMOS)
TXD (RS232C)
TX+ (RS422/RS485)
TXD (CMOS)
RX- (RS422/RS485)
6
8
9
7
2
4
5
3
1
PLC1 / COM1
*Do not use pin no. 6 of PLC1 / COM1.