Rentokil Rat Riddance Connect Instruction Manual Download Page 8

8

1

2

Internal Features To Be Aware of:

The Module features a number of switch sensors which detect the trap status:

Item 4.

  Paddle Activation Switch:  

This switch is activated when the trap is disarmed & a rodent is detected.

Item 5. 

 Trap Armed Switch: 

No visual indicator, but electronically activated when trap is armed.

User Interaction:

1.

   Status LED

2.

   Signal LED

3.

   Magnetic Switch

4.

   Paddle Activation 

Switch

5.

   Trap Armed Switch

6.

   Trap Base

7.

   Trap Break Back Arm

8. 

  Bait Tray

1. Understanding the Trap’s Features

Trap Features

1

3

2

5

8

6

4

7

Summary of Contents for Rat Riddance Connect

Page 1: ...onstruction and or configuration of the product and versions at any time without obligation All rights reserved No part of this document may be reproduced stored in a database or any other retrieval system or published in any form or way electronically mechanically digitally per photo print or microfilm or any other way without written permission from the author ...

Page 2: ...tallation 5 Installing the Batteries Service Process 1 Assess Trap Status 2 Clean Re Bait 3 Service Module 4 Test Paddle 5 Reset Trap Using the Interface 1 Using the Service Key 2 LED Icon Code 3 Service Modes 4 Service Visit 5 Radio Restart 6 Range Test 7 Testing the Paddle Switch 8 Arming the Trap 9 Module Warnings 10 Troubleshooting Fixes Further Information Technical Details Product Code Summa...

Page 3: ...ing use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Ensure trap is always disarmed before carrying out any service or functionality on the module Note A If the equipment is used in a manner not specified by the manufacturer then the protection provided b...

Page 4: ...Rentokil Connect Control panel and then server Connect signals the capture of a rat sending a message to the Connect Control Panel and then Server A technician will receive an alert and arrive promptly to empty clean service and reset the trapping device Rigorous testing and quality controls have been implemented at every stage of the manufacturing process to ensure that Rat Riddance Connect is a ...

Page 5: ...st to replace Theproductdescribedinthismanualissubjecttocontinuousdevelopment and improvement and Rentokil reserve the right to alter the specification or design without prior notice Rentokil cannot accept any liability for any loss or damage arising from the use of any information contained within this manual or from any incorrect use of the product described herein Rentokil can accept no liabili...

Page 6: ...used by changing for a new compatible trap Care must be taken to locate trapping devices away from pedestrian traffic to avoid false activation This can be prevented by mounting trapping devices on fixing brackets Extremely low temperatures i e unheated warehouses could affect Rat Riddance Connect s performance and may result in the trapping device entering low battery status mode High vibration d...

Page 7: ...arm 5 If neccessary secure the trap with a lanyard or via the rear holes to the floor wall or box to secure and control 6 It is also recommended that the traps front is always up against a surface or run for the rodent 7 Before arming the trap the technician can check the device and its connectivity level See Page 14 8 If Technician Test is required first disarm the device Perform Technician Test ...

Page 8: ...ivated when the trap is disarmed a rodent is detected Item 5 Trap Armed Switch No visual indicator but electronically activated when trap is armed User Interaction 1 Status LED 2 Signal LED 3 Magnetic Switch 4 Paddle Activation Switch 5 Trap Armed Switch 6 Trap Base 7 Trap Break Back Arm 8 Bait Tray 1 Understanding the Trap s Features Trap Features 1 3 2 5 8 6 4 7 ...

Page 9: ...supplied in box Installation Process 1 Prior to Installation While unpacking check for any signs of shipment damage and if found notify both transporter and supplier in writing within eight days of receipt with full details of the damage that has occurred Retain the equipment and packing materials for inspection Check that all parts have been received as ordered 2 Components for Installation 1 2 3...

Page 10: ... break back style traps are dangerous and can cause injury care must be taken on setup and ensure the necessary anchoring securing and protective casings are used where applicable Try to prevent the trapping device from being accidently moved knocked or removed by unauthorised persons Follow the RI Procedure for Connect Installation device scanning 4 Site Installation Example Floor Plan 3 Fitting ...

Page 11: ...tted back on to the trap either before or after the batteries are refitted Once the batteries are fitted the module will automatically start C LED Start Up Sequence Status LED Connection LED Code Click Upon inserting the batteries the startup sequence will automatically begin Ensure the trap is disarmed then remove Main Assembly from shoe using RI Service Key and remove the battery door Fit 3x AAA...

Page 12: ...Re Bait A Note Ensure trap is in disarmed state before handling and all actions performed before re arming 3 Service the Module If necessary remove service the module Then replace See Page 13 for more details on using the interface 4 Note Be careful not trap your fingers Test Paddle Test the switch by pressing the paddle B Clean trap in accordance with standard cleaning procedure and refill the ba...

Page 13: ...Restart Radio Radio Range Test Blue for first 5 seconds Orange for up to 10 seconds Red 10 seconds Hold the magnet close to the RI Icon the Status light flashes when recognised To signal to the Command Centre that the trap has been visited a Service Visit signal can be sent by holding the magnet next to the device for up to 5 seconds Timer starts when blue light starts flashing 4 Service Visit 5 S...

Page 14: ...er the device for 10 seconds until the status LED turns red 5 Radio Restart 6 Range Test 5 10 Secs 10 Secs Flashes Purple every 3 seconds Flashes Red every 3 seconds Flashes Yellow every 3 seconds Flashes Blue every 3 seconds Unit is trying to make a connection No signal Weak Signal Good Signal LED IDENTIFIER Range test mode will automatically exit after 1 hour To exit range test mode manually hol...

Page 15: ...ful arming 7 Testing the Paddle Switch Test the paddle activation switch by pressing the paddle If the switch is working effectively the Status LED will be yellow each time the paddle is pressed Note Ensure trap is disarmed before pressing the paddle Using the Interface Continued Each time the trap is armed the connection status will be shown on the Connection LED for 1 hour Flashes Red every 3 se...

Page 16: ... seconds Device Failure Both LEDs will flash red rapidly if there is a device failure Such failures are Host module comms broken Accelerometer fail No Signal Trap Connection Indicator will flash red every 3 seconds if there is no signal and no connection No Connection Trap Connection Indicator will flash purple every 3 seconds if there is a signal but no connection Using the Interface Continued ...

Page 17: ... a different Control Panel will require restarting the device and entering Range Test mode again Unsuccessful arming Yellow LED When arming the trap if the Status LED shows 10x yellow flashes this shows the paddle test has not been performed Carefully disarm the trap perform the paddle test then rearm the trap again Unsuccessful arming Red LED When arming the trap if the Status LED shows 10x red f...

Page 18: ...perature 20ºC to 50ºC 4ºF to 122ºF Storage Temperature 20ºC to 50ºC 4ºF to 122ºF Environmental rating Target IP65 Connect Details Interface 868 928MHz depending on local Approvals Rentokil Initial Propriatary Application Layer Protocol Max Number of 300 per control panel Rat Riddance Connect Further Information Technical Details Product Code Summary SKU Accessories 304751 Pest Key 304877 Retractab...

Page 19: ...he device L émetteur récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d Innovation Sciences et Développement économique Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 L appareil ne doit pas produire de brouillage 2 L appareil doit accepter tout brouillage radioélectrique subi même si le brouill...

Page 20: ...h incorporating both preventative and responsive strategies to enhance protection for your business through a consistent continuous pest control programme Neither the whole nor any part of the information described in this manual nor the product therein described may be adapted or reproduced in any form without prior written approval of Rentokil The product described in this manual is subject to c...

Reviews: