55
Fixscreen
®
150 (F)
en
➍
Slide the empty box into the back part of the side channel.
Secure the box to the side channel using Allen key 2,5 (DIN 915 M5x10). Do this at both sides.
Place the back side of the side channel with the empty box into its final position.
Mounting of side channel ‘G’
through the backside (ø5mm)
Mounting of side channel ‘D’
through the backside (ø5mm)
Mounting of coupling side
channel ‘K’ through the
backside (ø5mm)
Mounting of side channel
sideways ‘G’ (ø5mm)
Mounting of side channel
sideways ‘D’ (ø5mm)
Side channel S, G
The hole of ø10mm is always pre-drilled, the hole of ø5mm still needs to be drilled.
• Allow a distance of 750mm between two sequential holes for the assembly.
• Fix the screws and make sure that the screw head is integrated (flush-mounted) to prevent
obstruction of the H-PVC inner rail.
• The drillings need to be done as straight as possible to guarantee a good fastening of the
side channels (certainly in case of high wind load).
Side channel D
In case of side channel ‘D’, it is advisable to perform the drilling from the outside.
Take into account that in case of installation method 7B, the side channels are
placed in recess mounting position.
ø5
ø10
Ø
5
Ø5
➎
INSTALLATION METHOD 7A
Attention:
To be able to
disassemble the fabric roller
from beneath, the client must
foresee something under-
neath the box that can be
dismantled when choosing
the narrow side channel G.
The dimensions of this piece
of cladding must be: a mi-
nimum width corresponding
with the depth of the box
minus the depth of narrow
side channel and a minimal
height of 800 mm in case
of maximum width of 6000
mm, single screen.
demountable
demountable
Ø5
Ø
5
Ø
5
Ø5
Ø5
Ø
5