5
It reminds to respect the rules on the use of equipment suitable of working on the machine, such as helmets,
gloves, goggles, accident prevention shoes, jackets, protective ear plugs or headphones in noisy environments.
Our products are designed to operate according to the characteristics defined by our technical specifications that
must not be overlooked or passed for production needs.
Our technical department is at your disposal for problems when installing or starting the machine and can offer
the right solutions to overcome any problem.
THIS COMPONENT IS EXPRESSLY DESIGNED TO BE MOUNTED IN A MACHINE AND CANNOT WORK
INDEPENDENTLY.
IT IS ABSOLUTELY FORBIDDEN THE USE IF THE MACHINE IS NOT IN COMPLIANCE WITH THE LAW.
Particular attention to be given to operations of assembly and maintenance:
Securely block the mounting screws of the flange with a tightening torque recommended by the screw producers.
Screw
M6
M8
M10
M12
M14
Torque [Nm]
10,4
24,6
50,1
84,8
135
assistance
Renova is worldwide present with Agents and Distributors.
Contact Renova support
general instructions
HOW IT WORKS
The load cell is a transducer that converts the force applied by the roller on the bearing, in a proportional electric signal
that will be processed by the control system, generally composed by a PLC or a dedicated panel and which adjust the
controlled parameters of the unit (brake, clutch, engine, …).
The cell body is an elastic system which bends under load. The elastic part of the cell has the shape of a lamella properly
dimensioned in function of the load, to which the strain gauges are glued, made up of small grids of constantan
filaments, Wheatstone-bridge connected for a precise calibration.
When, under load, the lamella flexes and stretches, the extensometers accordingly
vary their electrical resistance.
When feeding the load cell, the change in the electrical output signal will be
proportional to the deformation of the strain gauges, so to the load applied to the cell
itself.
The output signal is normally of a few mV: hence, if the load cell is farther than 5 m
from the control unit, it may be necessary to amplify the signal through an external
amplifier or an ampli-PCD housed in the cell.