b) Switch the Power Supply OFF
Before installation, switch the electricity supply and corresponding circuit breaker and/or
automatic fuse OFF.
• Secure against unauthorized restart, e.g. by installing a warning sign.
• Check the power circuit for remaining voltage using an appropriate measuring device.
• Pay attention to the “Safety Instructions” section.
c) Connect Power Supply Leads
• Remove the outer insulation on the wires to a
maximum length of about 16 mm.
• Strip the insulation on each main cable wire to a length
of about 6 mm.
• Loosen the screws in the connection terminal
(9)
then connect power supply leads as shown in the
wiring diagram.
• Tighten the connection terminal
(9)
screws.
• Check that the cables are not squeezed, bent or damaged in any other way.
• Adjust the rotary controls
TIME (6)
,
SENS (5)
, and
LUX (4)
; refer to “Operation” for further instructions.
d) Attach the Faceplate
Align the brightness sensor
(11)
with the cut-out on the faceplate
(2)
, then press together
e) Switch the Power Supply ON
• Turn the corresponding circuit breaker and/or automatic fuse back ON.
• If the sensor does not function correctly, immediately turn the circuit breaker OFF and/or automatic fuse.
• Check the connection to the power circuit.
Operation
a) Switch Settings (ON / OFF / AUTO)
•
ON
: Power to connected load is always ON, independent of
LUX (4)
and
SENS (5)
settings.
•
OFF
: No power to connected load.
•
AUTO
: Power to switch is triggered by motion detection, depends on
LUX
(4)
and
SENS
(5)
settings.
b) Adjusting Motion Detection
The motion detector has three rotary controls that
can be used to change the switch-on time
TIME (6)
,
sensitivity
SENS (5)
, and the switch-on threshold for
ambient light levels
LUX (4)
.
c) “TIME” (Switch-On Time)
You can set a switch-on time to control how long the connected the load stays on.
• Rotating the
TIME (6)
dial counter-clockwise will decrease the duration. Rotating clockwise will increase
the duration.
• Settings include 10 seconds (±3 seconds) up to 12 minutes (±1 minute).
If new motion is detected during the switched-on time, the timer will reset and start again. The
consumer will stay switched on.
d) “SENS” (Sensitivity)
You can adjust the motion detection sensitivity levels.
• Rotating the
SENS (5)
dial counter-clockwise “-” will decrease sensitivity, Rotating clockwise “+”
increases it.
- Decreasing sensitivity reduces the sensor detection range.
- Increasing the sensitivity expands the range.
e) “LUX” (Brightness Setting)
You can adjust the switching threshold based on ambient light levels.
• Rotating
LUX (4)
counter-clockwise activates motion detection when it gets dark.
• Rotating
LUX (4)
clockwise towards the sun
symbol activates motion detection in brighter conditions.
f) Function Test
To optimize the sensor settings so that the connected load is triggered under the desired conditions, you may
need to perform a function test.
• Set the time
TIME (6)
to the minimum duration
10S
.
• Set the light
LUX
(4)
level to the highest setting
.
• Set the motion detection sensitivity
SENS (5)
to the middle setting.
• Walk across the detection area. The motion detector will activate the connected load if it detects a
movement within the detection area.
If needed, fine tune the rotary controls after the functional test.
10 mm
6 mm
Troubleshooting
Problem
Suggestion
The connected
load does not
switch on.
• Check the setting for the the brightness control
LUX
(4)
. If it is too low it will activate
in the dark.
• Check if there is a power supply and if the connected device (i.e. a bulb) functions
correctly.
• Increase the motion detection sensitivity
SENS
(5)
.
• Movements within the detection area are too rapid, and are filtered out by the
electronic system, in order to prevent switching errors.
• The switch
(10)
may be in the
OFF
position. Set it to
ON
or
AUTO
.
The connected
load is always
on.
• Constant movements occur within the detection area; this may also be a
movement in the adjacent room due to the HF technology used. Decrease the
motion detection sensitivity level
SENS (5)
.
• New movement is detected before the previous switch on time
TIME
(6)
has
elapsed. Try setting a shorter switch on time.
• The switch
(10)
may be in the
ON
position, set it to
OFF
or
AUTO
.
Care and Cleaning
• The product is generally maintenance-free. Any
repair or maintenance work must be carried out
by a specialist.
• Do not use any aggressive cleaning agents,
rubbing alcohol or other chemical solutions as
they can cause damage to the housing and
malfunctioning.
• Clean the product with a dry, fibre-free cloth.
Declaration of Conformity (DOC)
Conrad Electronic SE, Klaus-Conrad-Straße 1,
D-92240 Hirschau hereby declares that this product
conforms to the 2014/53/EU directive.
Click on the following link to read the full
text of the EU declaration of conformity:
www.conrad.com/downloads
Select a language by clicking on a flag
symbol and enter the product order
number in the search box. You can
then download the EU declaration of
conformity in PDF format.
Disposal
Electronic devices are recyclable
waste and must not be disposed of in
the household waste. At the end of its
service life, dispose of the product in
accordance with applicable regulatory
guidelines. You thus fulfill your statutory
obligations and contribute to the
protection of the environment.
Technical Data
a) General
Input voltage ................................ 220-240 V/AC,
50 / 60 Hz
Static power consumption ...........0.63 W
Working power consumption .......1.36 W
Rated load ................................... max. 1200 W
(resistive)
max. 300 W
(inductive)
Devices with resistive loads include light
bulbs, heaters, etc.
Devices with inductive loads include
engines, control gears (e.g. for LEDs),
conventional transformers, energy
saving bulbs, etc.
Detection angle ............................180º
Installation height .........................1 - 1.8 m
Detection motion speed ...............0.6 - 1.5 m/s
Detection distance ....................... 5 -15 m
(adjustable)
HF system ................................... 5.8 GHz, CW
radar, ISM band
Switch-on time ............................. 10 - 90 s (±3 s),
3 - 12 min (±1
min)
Light levels (lux) ........................... 0.1 / 3 / 30 / 300 /
2000
Material ........................................PC
Operation current .........................24 mA
Protection type .............................IP20
Installation location ...................... Dry enclosed
rooms
Frequency ........................................ 5.725 – 5.875 GHz
Transmission power.....................<10 mW
Protection class ...........................2
Operating/storage conditions ....... -20 to +50 ºC,
<93 % RH
(non-condensing)
Internal bore ................................ø5.5 mm
Product dimensions ..................... 80 x 80 x 32 mm
(W x H x D)
Product weight .............................100 g
b) Dimension Drawing
32 mm
50 mm
80 mm
50 mm
80 mm
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights
including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represent the technical status at the time of printing.
Copyright 2020 by Conrad Electronic SE.
*2108038_v3_0520_02_dh_m_en