Renkforce 2108038 Operating Instructions Manual Download Page 4

b) Switch the Power Supply OFF

  Before installation, switch the electricity supply and corresponding circuit breaker and/or 

automatic fuse OFF.

•  Secure against unauthorized restart, e.g. by installing a warning sign.
•  Check the power circuit for remaining voltage using an appropriate measuring device.
•  Pay attention to the “Safety Instructions” section.

c) Connect Power Supply Leads 

•  Remove the outer insulation on the wires to a 

maximum length of about 16 mm.

•  Strip the insulation on each main cable wire to a length 

of about 6 mm.

•  Loosen the screws in the connection terminal 

(9)

 then connect power supply leads as shown in the 

wiring diagram.

•  Tighten the connection terminal 

(9)

 screws.

•  Check that the cables are not squeezed, bent or damaged in any other way.
•  Adjust the rotary controls 

TIME (6)

SENS (5)

, and 

LUX (4)

; refer to “Operation” for further instructions.

d) Attach the Faceplate

Align the brightness sensor 

(11)

 with the cut-out on the faceplate 

(2)

, then press together

e) Switch the Power Supply ON

•  Turn the corresponding circuit breaker and/or automatic fuse back ON.
•  If the sensor does not function correctly, immediately turn the circuit breaker OFF and/or automatic fuse.
•  Check the connection to the power circuit.

Operation 

a) Switch Settings (ON / OFF / AUTO)

• 

ON

: Power to connected load is always ON, independent of 

LUX (4)

 and 

SENS (5)

 settings.

• 

OFF

: No power to connected load.

• 

AUTO

: Power to switch is triggered by motion detection, depends on 

LUX 

(4)

 and 

SENS

 

(5)

 settings.

b) Adjusting Motion Detection 

The motion detector has three rotary controls that 

can be used to change the switch-on time 

TIME (6)

sensitivity 

SENS (5)

, and the switch-on threshold for 

ambient light levels 

LUX (4)

.

c) “TIME” (Switch-On Time)

You can set a switch-on time to control how long the connected the load stays on.
•  Rotating the 

TIME (6)

 dial counter-clockwise will decrease the duration. Rotating clockwise will increase 

the duration. 

•  Settings include 10 seconds (±3 seconds) up to 12 minutes (±1 minute).

  If new motion is detected during the switched-on time, the timer will reset and start again. The 

consumer will stay switched on.

d) “SENS” (Sensitivity)

You can adjust the motion detection sensitivity levels.
•  Rotating the 

SENS (5)

 dial counter-clockwise “-” will decrease sensitivity, Rotating clockwise “+” 

increases it.

 - Decreasing sensitivity reduces the sensor detection range.
 - Increasing the sensitivity expands the range.

e) “LUX” (Brightness Setting)

You can adjust the switching threshold based on ambient light levels.
•  Rotating 

LUX (4)

 counter-clockwise activates motion detection when it gets dark.

•  Rotating 

LUX (4) 

clockwise towards the sun 

 symbol activates motion detection in brighter conditions. 

f) Function Test

To optimize the sensor settings so that the connected load is triggered under the desired conditions, you may 

need to perform a function test.
•  Set the time 

TIME (6)

 to the minimum duration 

10S

•  Set the light 

LUX

 

(4)

 level to the highest setting 

•  Set the motion detection sensitivity 

SENS (5)

 to the middle setting.

•  Walk across the detection area. The motion detector will activate the connected load if it detects a 

movement within the detection area.

  If needed, fine tune the rotary controls after the functional test.

10 mm

6 mm

Troubleshooting

Problem

Suggestion

The connected 

load does not 

switch on.

•  Check the setting for the the brightness control 

LUX

 

(4)

. If it is too low it will activate 

in the dark. 

•  Check if there is a power supply and if the connected device (i.e. a bulb) functions 

correctly.

•  Increase the motion detection sensitivity 

SENS

 

(5)

.

•  Movements within the detection area are too rapid, and are filtered out by the 

electronic system, in order to prevent switching errors.

•  The switch 

(10)

 may be in the 

OFF

 position. Set it to 

ON

 or 

AUTO

.

The connected 

load is always 

on.

•  Constant movements occur within the detection area; this may also be a 

movement in the adjacent room due to the HF technology used. Decrease the 

motion detection sensitivity level 

SENS (5)

.

•  New movement is detected before the previous switch on time 

TIME

 

(6)

 has 

elapsed. Try setting a shorter switch on time.

•  The switch 

(10)

 may be in the 

ON

 position, set it to 

OFF

 or 

AUTO

.

Care and Cleaning

•  The product is generally maintenance-free. Any 

repair or maintenance work must be carried out 

by a specialist.

•  Do not use any aggressive cleaning agents, 

rubbing alcohol or other chemical solutions as 

they can cause damage to the housing and 

malfunctioning.

•  Clean the product with a dry, fibre-free cloth.

Declaration of Conformity (DOC)

Conrad Electronic SE, Klaus-Conrad-Straße 1, 

D-92240 Hirschau hereby declares that this product 

conforms to the 2014/53/EU directive.

  Click on the following link to read the full 

text of the EU declaration of conformity: 

www.conrad.com/downloads

 

Select a language by clicking on a flag 

symbol and enter the product order 

number in the search box. You can 

then download the EU declaration of 

conformity in PDF format.

Disposal

 Electronic devices are recyclable 

waste and must not be disposed of in 

the household waste. At the end of its 

service life, dispose of the product in 

accordance with applicable regulatory 

guidelines. You thus fulfill your statutory 

obligations and contribute to the 

protection of the environment.

Technical Data

a) General

Input voltage ................................ 220-240  V/AC, 

50 / 60 Hz

Static power consumption ...........0.63 W
Working power consumption .......1.36 W
Rated load ................................... max. 1200 W

 

 

(resistive) 

max. 300 W   

(inductive)

  Devices with resistive loads include light 

bulbs, heaters, etc.

 

Devices with inductive loads include 

engines, control gears (e.g. for LEDs), 

conventional transformers, energy 

saving bulbs, etc.

Detection angle ............................180º
Installation height .........................1 - 1.8 m
Detection motion speed ...............0.6 - 1.5 m/s
Detection distance ....................... 5 -15 m 

(adjustable) 

HF system ................................... 5.8 GHz, CW 

radar, ISM band

Switch-on time ............................. 10 - 90 s (±3 s),  

3 - 12 min (±1 

min)

Light levels (lux) ........................... 0.1 / 3 / 30 / 300 /  

 2000 

Material ........................................PC
Operation current .........................24 mA
Protection type .............................IP20
Installation location ...................... Dry  enclosed 

rooms

Frequency ........................................ 5.725 – 5.875 GHz
Transmission power.....................<10 mW
Protection class ...........................2
Operating/storage conditions ....... -20 to +50 ºC,  

<93 % RH  

(non-condensing)

Internal bore ................................ø5.5 mm 
Product dimensions ..................... 80 x 80 x 32 mm 

(W x H x D)

Product weight .............................100 g

b) Dimension Drawing

32 mm

50 mm

80 mm

50 mm

80 mm

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights 

including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data 

processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication 

represent the technical status at the time of printing.
Copyright 2020 by Conrad Electronic SE. 

*2108038_v3_0520_02_dh_m_en

Summary of Contents for 2108038

Page 1: ...er Bedienungsanleitung an Dritte weiter Dieses Produkt erfüllt die gesetzlichen nationalen und europäischen Anforderungen Alle enthaltenen Firmennamen und Produktbezeichnungen sind Warenzeichen der jeweiligen Inhaber Alle Rechte vorbehalten Lieferumfang Bewegungsmelder Bedienungsanleitung Aktuelle Bedienungsanleitungen Laden Sie aktuelle Bedienungsanleitungen über den Link www conrad com downloads...

Page 2: ...end den Drehregler SENS 5 der zur Anpassung der Empfindlichkeit Reichweite vorgesehen ist in die mittlere Stellung 10 mm 6 mm Laufen Sie nun durch den Erfassungsbereich Sobald der Bewegungsmelder innerhalb des Erfassungsbereichs eine Bewegung registriert aktiviert dieser den angeschlossenen Verbraucher Bei Bedarf können Sie nach der Funktionsprüfung noch zusätzliche Feineinstellungen an den Drehre...

Page 3: ... intended to be installed and used in dry indoor rooms it must not get damp or wet Safety Instructions Read the operating instructions carefully and especially observe the safety information If you do not follow the safety instructions and information on proper handling in this manual we assume no liability for any resulting personal injury or damage to property Such cases will invalidate the warr...

Page 4: ... The connected load does not switch on Check the setting for the the brightness control LUX 4 If it is too low it will activate in the dark Check if there is a power supply and if the connected device i e a bulb functions correctly Increase the motion detection sensitivity SENS 5 Movements within the detection area are too rapid and are filtered out by the electronic system in order to prevent swi...

Page 5: ...ns attentivement Le symbole de la flèche indique des informations spécifiques et des conseils spéciaux pour le fonctionnement Ce produit dispose d une classe de protection II Le produit doit être utilisé exclusivement en intérieur dans des locaux fermés et secs Il ne doit ni être mouillé ni prendre l humidité Consignes de sécurité Lisez attentivement le mode d emploi et observez particulièrement l...

Page 6: ... de besoin ajustez avec précision les commandes rotatives après le test de fonctionnement 10 mm 6 mm Dépannage Problème Suggestion La charge connectée ne s allume pas Vérifiez le réglage de la commande de luminosité LUX 4 S il est trop bas la commande s active dans le noir Vérifiez s il existe une alimentation électrique et si l appareil connecté notamment une ampoule fonctionne correctement Augme...

Page 7: ...uitend geschikt voor toepassing en gebruik in droge ruimtes binnenshuis Het mag niet vochtig of nat worden Veiligheidsinstructies Lees de gebruiksaanwijzing aandachtig door en neem vooral de veiligheidsinformatie in acht Indien de veiligheidsinstructies en de aanwijzingen voor een juiste bediening in deze gebruiksaanwijzing niet worden opgevolgd aanvaarden wij geen verantwoordelijkheid voor hierui...

Page 8: ...g Probleem Suggestie De aangesloten belasting kan niet worden ingeschakeld Controleer de instelling voor de helderheidsregeling LUX 4 Als het te laag is zal het in het donker worden geactiveerd Controleer of er een voeding is en of het aangesloten apparaat d w z een lamp correct functioneert Verhoog de gevoeligheid van de bewegingsdetectie SENS 5 Bewegingen binnen het detectiegebied zijn te snel e...

Reviews: