  See ‘Technical data’ for suitable installation environments (IP class).

  Depending on your installation location you either place the product onto the DIN 

rail first and then connect power, or the other way round. Read the corresponding 

section in this chapter first.

 

At all times, make sure not to supply any power to the product as long as installation 

is not completed.

a) Power Supply

  Only supply power to the product after installation is complete.

Requirements

•  The device only requires one source of power to operate, and the power supply is designed 

to be redundant. If two sources of power are connected and one fails, the unit will immediately 

switch to the alternative power source. 

•  Both sources of power are independent and provide reverse-polarity voltage protection. If 

both are connected at the same time, the one with the highest voltage will be used.

• 

The  terminal  block  requires  a  stabilized  12  -  56  V/DC  input.  See  ‘Technical  data’  for 

requirements.

• 

The power adapter must supply stabilized 12 V/DC. See ‘Technical data’ for requirements.

Grounding Connection   

•  The screw contact marked with the grounding symbol 

(2)

 is available for connection to the 

electrical grounding. 

•  Connect it to the electrical grounding of the electrical control cabinet in which/to which the 

network switch is installed/connected.

Terminal Block

•  Connect the terminal block 

(6) to the 12 - 56 V/DC terminal input (4)

.

• 

Connect one end of the power supply cable (not included) to the terminal block (6)

, and 

connect the other end to the power supply.

Observe the polarity (-/+) indications printed above the terminal block.

Power Adapter (not supplied)
Connect one end of the power adapter to the power 12 V/DC power input jack (3)

, and connect 

the other end to the power supply.

Power supply check

After installation, check the power indicator 

(7)

 on the front panel to make sure that the switch 

is receiving power.

b) Place on DIN Rail

• 

The DIN rail has to comply with EN 55022 (overall width 3.5 cm, overall height 0.75 cm). The 

product may not be installed on any other mounting rails!

• 

Place the product on the DIN rail and secure it in place.

c) Network Cable Connection

•  Use suitable network cables to connect devices and computers to the switch ports.
•  All network ports supports auto uplink, which means that no crosslink cables are necessary 

to connect multiple network switches.

• 

Make sure the cables are not bent or crushed.

•  We recommend to mark the network cables with suitable adhesive labels or other devices. 

This will allow you in case of a fault to know perfectly which connections need to be checked

.

LED Indicators

The LED indicators provide real-time operating status information.

LED

Status

Description

PWR (7)

ON

Receiving power

OFF

No power received

Link/Act 

(9)

Green “ON”

Link active

Green “OFF”

Link inactive

Green “flashing”

Network activity

Speed 

(8)

Amber “ON”

Switch is operating at 100 Mbit/s

Amber “flashing”

Switch is operating at 10 Mbit/s

Care and Cleaning

• 

Disconnect the product from the mains before each cleaning.

• 

Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as it 

can cause damage to the housing and malfunctioning.

• 

Clean the product with a dry, fibre-free cloth.

Disposal

  Electronic devices are recyclable waste and must not be disposed of in the 

household waste. At the end of its service life, dispose of the product in accordance 

with applicable regulatory guidelines.

You thus fulfill your statutory obligations and contribute to the protection of the environment.

Technical Data

Input power ...................................

 12 - 56 V/DC, 1 A, stabilized (terminal block, 2-pin, 5 mm)

 

12 V/DC, 1 A (input jack 2.5 mm)

Power adapter ..............................

12 V/DC, 1 A  (sold separately) 

Number of ports

 ............................

 5 x RJ45 (item 1697433)

 

8 x RJ45 (item 1697434)

Power consumption ......................

 max. 4 W (item 1697433)

 

max. 6 W (item 1697434)

MAC address

 ................................ 1 K

Buffer memory .............................. 448 Kbits

Media device interface

 ..................

Auto-MDI/MDI-X, auto-negotiation, non-blocking

IEEE .............................................

802.3 10 BaseT, 802.3u 100 BaseTX, 802.3x Flow Control

EMI

 ............................................... FCC Class A Part 15, VCCI Class A

EMS

 ..............................................

 EN61000-4-2 (ESD), EN61000-4-3 (RS),EN61000-4-8

IEC ................................................

 IEC 60068-2-27 (shock), IEC 60068-2-32 (freefall),

 

IEC 60068-2-6 (vibration)

Filtering / forwarding .....................

100 Mbps port - 148,800 pps, 10M bps port - 14,880 pps

Transmission method ................... Store and forward

LED indicators

 ..............................

 Port: Link/Act (green), Speed (amber)

 

Unit: Power (amber)

Ingress protection rating ...............

IP30 (housing only)

Mounting

 .......................................

DIN rail

Operating temperature .................

-40 to +75 °C, 10 – 90 % RH (non-condensing)

Storage temperature .....................

-40 to +75 °C, 10 – 90 % RH (non-condensing)

Dimensions (H x W x D)

 ...............

 25 x 130 x 98 mm (item 1697433)

 

31 x 142 x 106 mm (item 1697434)

Weight ..........................................

 315 g (item 1697433)

 

365 g (item 1697434)

Summary of Contents for 1697433

Page 1: ...ante Stromversorgung Es kann 12 56 V DC über die Verkabelung und 12 V DC über das Netzteil nicht mitgeliefert aufnehmen Das Gerät ist nur für den Innengebrauch geeignet Nicht im Freien verwenden Kontakt mit Feuchtigkeit muss unbedingt vermieden werden Aus Sicherheits und Zulassungsgründen dürfen Sie das Produkt nicht umbauen und oder verändern Falls Sie das Produkt für andere als die zuvor genannt...

Page 2: ...DC Netzeingang 3 und das andere Ende an der Stromversorgung an Stromversorgung überprüfen Überprüfen Sie nach der Installation die Betriebsanzeige 7 auf der Vorderseite um sicherzustellen dass der Switch mit Strom versorgt wird b Auf Hutschiene setzen Die Hutschiene muss EN 55022 entsprechen Gesamtbreite 3 5 cm Gesamthöhe 0 75 cm Das Produkt darf nicht auf anderen Hutschienen montiert werden Setze...

Page 3: ... for indoor use only Do not use it outdoors Contact with moisture must be avoided under all circumstances For safety and approval purposes you must not rebuild and or modify this product If you use the product for purposes other than those described above the product may be damaged In addition improper use can result in short circuits fires electric shocks or other hazards Read the instructions ca...

Page 4: ...all width 3 5 cm overall height 0 75 cm The product may not be installed on any other mounting rails Place the product on the DIN rail and secure it in place c Network Cable Connection Use suitable network cables to connect devices and computers to the switch ports All network ports supports auto uplink which means that no crosslink cables are necessary to connect multiple network switches Make su...

Page 5: ...bénéficie d une large plage de température de fonctionnement et est accompagné d un rail de montage DIN Le commutateur comporte une alimentation électrique redondante Il peut prendre en charge une tension de 12 56 V CC par câblage et de 12 V CC via un adaptateur secteur non fourni Ce produit est prévu pour un usage à l intérieur exclusivement Ne l utilisez pas à l extérieur Dans tous les cas le co...

Page 6: ...et branchez l autre extrémité à la prise d alimentation Vérification de l alimentation électrique Après l installation vérifiez le voyant de l alimentation 7 sur le panneau avant pour vous assurer que le commutateur reçoit de l électricité b Installation sur le rail DIN Le rail DIN doit être conforme avec la norme NF EN 55022 largeur totale de 3 5 cm hauteur totale de 0 75 cm Le produit ne doit êt...

Page 7: ...iddelgrote netwerkomgevingen Het is compact heeft een breed bedrijfstemperatuurbereik en komt met een DIN railmontage De schakelaar heeft een back upvoeding Het kan 12 56 V DC ontvangen via bedrading en 12 V DC voeding via stroomadapter niet inbegrepen Dit product is alleen bedoeld voor gebruik binnenshuis Gebruik het niet buitenshuis Contact met vocht moet absoluut worden vermeden Om veiligheids ...

Page 8: ... geen enkele andere montagerails worden geïnstalleerd Plaats het product op de DIN rail en zet deze op zijn plek vast c Een Netwerkkabel Aansluiten Gebruik geschikte netwerkkabels om apparaten en computers aan te sluiten op de schakelaarpoorten Alle netwerkpoorten ondersteunen auto uplink wat betekent dat er geen kabels voor dwarsverbinding nodig zijn om meerdere netwerkschakelaars aan te sluiten ...

Reviews: