  If the ceiling light does not light up, switch off the mains voltage immediately (take 

out the fuse or switch off the circuit breaker, and switch off the earth fault circuit 

interrupter).

•  Thereafter, check the connections of the ceiling lamp. 
•  Replace the round light cover removed at the beginning onto the mounting plate and lock it by 

turning it clockwise slightly to the right (see fig. 10). At that, the three grooves on the outside 

circumference of the light cover must engage with three cap nuts on the inner circumference 

of the mounting plate.

Operation

•  Once the mounting work is complete, the motion detector operating on the microwave 

principle can be configured.

The functioning of the motion detector is tested by moving under the mounted ceiling 

light:
•  The entire area must be cleared up and secured to eliminate any tripping or injury hazards 

before the functional test! In case of insufficient lighting of the area, adequate lighting must 

be ensured by other light sources.

•  Once the power supply of the ceiling light is switched on, the motion detector switches to the 

warm-up phase lasting from approx. 30 seconds to a maximum of 1 minute.

•  It is automatically followed by a transition to the automatic mode. Switch off the ceiling lights 

by the light switch and test the trigger function by passing under the motion detector. To do 

this, set the LUX luminosity switch to <200 and the TIME switch for power-on time to 10 s. 

See configuration table. For this purpose, the light cover must be removed and then replaced 

again.

•  Once the motion detector in the ceiling light receives a valid triggering signal from within the 

detection radius (e.g. caused by the movement of a person), the ceiling light switches on for 

the selected power-on time. 

  The actual detection radius can be determined by slow walking!

Configuration table

1

0

1

2

3

4

5

6

LUX

<200 LUX

0

0

x

x

x

x

<60 LUX

0

1

x

x

x

x

<20 LUX

1

0

x

x

x

x

<5 LUX

1

1

x

x

x

x

SENS

5 m

x

x

0

0

x

x

3.5 m

x

x

0

1

x

x

2 m

x

x

1

0

x

x

1 m

x

x

1

1

x

x

TIME

10 s

x

x

x

x

0

0

1 min

x

x

x

x

0

1

4 min

x

x

x

x

1

0

10 min

x

x

x

x

1

1

1=ON, 0=OFF, x=ON or OFF

Switch 1 to the left, switch 6 to the right

•  After the functional test of the motion detector, set the switches 

 - LUX (luminosity)
 - TIME  (power-on time)
 - SENS  (detection radius)

as desired

Care and cleaning

•  The product is maintenance-free except for lamp replacement.
•  Disconnect the product from the power supply before cleaning. 
•  Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as 

they can cause damage to the housing and malfunctioning.

•  Only use a dry, fibre-free cloth to clean the product. Optionally, the dust can be removed with 

a clean, soft brush.

  Never use a damp cloth or water to clean the ceiling light.

Disposal

  Electronic devices are recyclable waste and must not be disposed of in the 

household waste. At the end of its service life, dispose of the product according to 

the relevant statutory regulations.

You thus fulfil your statutory obligations and contribute to the protection of the environment.

Technical data

Input voltage/current .....................................220 – 240 V/AC, 50 Hz
Lamp (not included) ...................................... Light bulbs: 2 x E27, max. 40 W, or  

energy-saving lamp: 2 x E27, max. 13 W, or  

LED: 2 x E27, max. 10 W 

Suitable installation height ............................2.5 – 4 m
Detection range ............................................ 360° and radius max. 5 m  

(4 steps: 1 / 2 / 3.5 / 5 m)

Detection speed ............................................0.3 – 2 m/s
Power-up time ..............................................4 steps: 10 sec. / 1 min. / 4 min. / 10 min.
Luminosity ....................................................adjustable in 4 steps: <5 / <20 / <60 / <200 LUX
IP class .........................................................IP20
Protection class ............................................I
Operating conditions .....................................-5 to +45 ºC, <90 % RH
Storage conditions ........................................-15 to +55 ºC, <90 % RH
Dimensions (Ø x H) ......................................348 x 117 mm
Weight ..........................................................880 g

Summary of Contents for 1483920

Page 1: ...schalter auszuschalten Schalten Sie die elektrische Netzzuleitung allpolig ab indem Sie die zugeh rige Stromkreissicherung entfernen bzw den Sicherungsautomaten abschalten Schalten Sie danach den zuge...

Page 2: ...mindestens 30 mm tief bohren und D bel b ndig mit der Decke einsetzen Entfernen Sie die u ere Isolierung der Netzzuleitung auf einer L nge von maximal etwa 16 mm Isolieren Sie die drei Kabel der Netz...

Page 3: ...t TIME auf 10s einstellen Siehe Einstellungstabelle Hierzu muss die Leuchtenabdeckung entfernt und danach wieder angebaut werden Sobald der Bewegungsmelder in der Deckenleuchte innerhalb des Erkennung...

Page 4: ...with an appropriate testing device Operating instructions Overhead light with movement detector Item No 1483920 Intended use The product is intended for illuminating indoor areas it may only be insta...

Page 5: ...e ceiling Remove the outer insulation on the mains cable to a maximum length of about 16 mm Remove insulation of the three supply cables for a length of about 6 mm The cable of the protective conducto...

Page 6: ...table For this purpose the light cover must be removed and then replaced again Once the motion detector in the ceiling light receives a valid triggering signal from within the detection radius e g cau...

Page 7: ...suffit pas d teindre la lampe seule Mettez le circuit lectrique enti rement hors tension soit en actionnant le coupe circuit soit en enlevant le fusible Puis coupez le disjoncteur diff rentiel Prot ge...

Page 8: ...le d alimentation sur une longueur de 16 mm maximum Isolez les trois c bles du circuit lectrique sur une longueur d environ 6 mm Le c ble de protection c ble jaune vert doit mesurer au moins 6 mm de p...

Page 9: ...doit tre enlev et remis en place par la suite D s que le d tecteur de mouvements dans le plafonnier re oit dans le rayon de d tection un signal de d clenchement ex caus par le mouvement d une personne...

Page 10: ...af door de desbetreffende zekering van het circuit eruit te halen resp de slagpenzekering uit te schakelen Schakel vervolgens de bijbehorende aardlekschakelaar uit Zorg ervoor dat de stroom niet per...

Page 11: ...Verwijder de buitenste isolatie van de stroomkabel op een maximale lengte van ongeveer 16 mm Verwijder de isolatielaag van de drie kabels in denetleiding over een lengte van ongeveer 6 mm De aardekab...

Page 12: ...ordt de lamp ingeschakeld en blijft deze de ingestelde tijd branden De werkelijke detectieafstand kunt u door langzaam te lopen vaststellen Instellingentabel 1 0 1 2 3 4 5 6 LUX 200 LUX 0 0 x x x x 60...

Reviews: