UCC T3 installation guide

Document part number H-1000-7578-02-A

 

     

UCC T3 installation guide

www.renishaw.com

 

 

Issued 04 2019

1

Summary of Contents for UCC T3

Page 1: ...UCC T3 installation guide Document part number H 1000 7578 02 A UCC T3 installation guide www renishaw com Issued 04 2019 1...

Page 2: ...of the Microsoft Corporation All trademarks and trade names are acknowledged WEEE The use of this symbol on Renishaw products and or accompanying documentation indicates that the product should not be...

Page 3: ...surements and must therefore be treated with care Changes to Renishaw products Renishaw reserves the right to improve change or modify its hardware or software without incurring any obligations to mak...

Page 4: ...t the UCC T3 controller is in compliance with the relevant provisions of directives 2004 108 EC and 2006 95 EC Contact Renishaw plc or visit www renishaw com knowledgebase for the full EU declaration...

Page 5: ...cy energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to...

Page 6: ...ine safety WARNING Switching off or isolating the UCC T3 may NOT prevent unexpected machine movement The user is advised to isolate the machine from the electricity supply compressed air or other ener...

Page 7: ...category II Pollution degree 2 NOTE It may be necessary to house UCC T3 in a suitable electrical enclosure according to the installation s environmental conditions to obtain a higher IP rating NOTE Fo...

Page 8: ...References and associated documents Please use the following link for all Renishaw documentation www renishaw com cmmguides UCC T3 installation guide www renishaw com Issued 04 2019 8...

Page 9: ...ir pressure sensors crash detectors and all axis inner and outer travel limit switches Accepts two uncommitted general purpose input signals and generates one uncommitted general purpose output signal...

Page 10: ...Control electronics for probes and peripheral devices attached to the CMM LEDs visible through the front panel of the UCC T3 enclosure indicate the operational status Sub circuits in the unit control...

Page 11: ...331 0007 MCUlite 2 joystick A 5518 0025 PSU 600 W 60 V cable medium large machines UCC T3 accessories A 5518 0005 UCC T3 bracket kit A 5518 0010 UCC T3 connector kit including USB cable A 5518 0011 UC...

Page 12: ...the software include Basic machine system diagnostics Operation with Renishaw s machine checking gauge enabling the user to complete frequent volumetric accuracy tests to ensure the CMM is running wit...

Page 13: ...t least 300 Mbytes The processor speed and RAM requirements are not excessive if the PC supports the operating system and application software it will almost certainly support the UCC controller opera...

Page 14: ...left unconnected at the machine end Motor screens should be connected to both the UCC T3 and the motor housing Please refer to appropriate product installation guides when other Renishaw components PH...

Page 15: ...ssure Air pressure low Crash Crash switch activated Scale failure Scale readhead failed Scale mis count Scale not connected Overspeed The position demand has exceeded an internal defined limit Failure...

Page 16: ...imum clearance gap of 10 mm is necessary between the sides of the unit and any potential obstruction The dimensions shown on the above drawing are in mm in Fitting mounting brackets for 19 inch rack m...

Page 17: ...terconnecting many of the sub systems e g a probe head in a measuring system TP2 TP20 TP6 two wire touch trigger probe system for UCC T3 with manual probe head TP200 touch trigger probe system for UCC...

Page 18: ...PH10 probe head and two wire touch trigger probe system for UCC T3 PH10 probe head and TP200 touch trigger probe system for UCC T3 UCC T3 installation guide www renishaw com Issued 04 2019 18...

Page 19: ...on green amber red LED flashing off on LED flashing red green LED off X Any condition USB comms Servo status Probe seated Error Description No power to UCC T3 X X Download successful amps not engaged...

Page 20: ...LEDs after about 15 seconds When power cycling a minimum of 10 seconds is recommended between power removal and reconnection After the UCC T3 has completed its self test the system is ready for the so...

Page 21: ...oller is supported on UCCsuite version 4 4 5 software or later The UCCsuite software is automatically installed when the application is run The software can be obtained online at www renishaw com cmms...

Page 22: ...enishaw Pin Function A1 0 V A2 24 V to 80 V A3 0 V DC power specification Voltage 24 V to 80 V Current input to 10 A The UCC T3 controller requires 30 W of power to support the controller functions in...

Page 23: ...must ensure that the power supply used in the installation will permit any regenerative voltage to be accepted without failure NOTE If the power supply is not able to withstand this regenerative volt...

Page 24: ...erence Shell Screen The table shows the default polarity configurations for all pins NOTE The motor and tacho polarities on the UCC T3 controller are software configured during the installation proces...

Page 25: ...MCU connector Supports the Renishaw MCUlite 2 MCU5 and MCU W joysticks UCC T3 installation guide www renishaw com Issued 04 2019 25...

Page 26: ...Machine I O The 44 way high density socket provides connection for the CMM I O The table below details the I O pinout UCC T3 installation guide www renishaw com Issued 04 2019 26...

Page 27: ...limit CMM X axis limit switch input 27 Y axis outer limit CMM Y axis limit switch input 28 Y axis outer limit CMM Y axis limit switch input 29 Z axis outer limit CMM Z axis limit switch input 30 Z ax...

Page 28: ...hat the CMM s drives are mechanically connected to the moving elements of the machine i e in their normal condition The input should be open circuit or held high when a CMM has been temporarily de clu...

Page 29: ...t is activated the UCC T3 system will perform a maximum movement deceleration in all axes to a stop and then perform a controlled axis back off in the opposite direction as if a trigger event occurred...

Page 30: ...1 A All connections to this connector should be fitted by a competent technician or engineer and all wires should be sleeved Any emergency stop devices added to the E STOP chain should meet the requir...

Page 31: ...ing been determined by user risk assessment CAUTION It is strongly recommended that the CMM manufacturer or retrofitter includes a periodic test of the emergency stop and if fitted the associated rese...

Page 32: ...to move in all six directions using the MCU joystick 2 Hit the emergency stop button For some systems the button must then be unlocked by twisting it as indicated by the arrows on the button 3 Ensure...

Page 33: ...view on face of socket rear of plug Communication settings This port is configured for the following communication settings Baud rate 9600 Data 7 bits Parity Even Stop 1 bit Connection to a PHC10 3 To...

Page 34: ...0 3 25 way D connector Signal UCC T3 9 way D connector Pin 2 Tx Pin 2 Pin 3 Tx Pin 3 Pin 4 RTS CTS Pin 8 Pin 5 CTS RTS Pin 7 Pin 7 Ground Pin 5 UCC T3 installation guide www renishaw com Issued 04 201...

Page 35: ...T3 will accept the trigger signals from the unit The connector is a 9 pin D socket pinout as follows Pin number Function Pin number Function 1 PICS STOP 6 Reserved 2 PICS probe power off PPOFF 7 PICS...

Page 36: ...tch Q 3 Error 11 Limit switch P 4 Reference mark 12 Reference mark 5 B signal 13 B signal 6 A signal 14 A signal 7 5 25 V supply 15 Inner screen 8 Reserved Shell Scale supply voltage is 5 25 V at 350...

Page 37: ...to the Renishaw range of RGH24 readheads If the error signal is not integrated into the connected readhead then it is necessary to configure the connection as indicated below error pin 3 link to 5 25...

Page 38: ...Limit switch interface circuit Scale based limit switch error signals are as integrated to the Renishaw range of RGH24 readheads UCC T3 installation guide www renishaw com Issued 04 2019 38...

Page 39: ...ion Pin number Function 1 Not connected 9 0 V supply 2 0 V supply 10 Not connected 3 Not connected 11 Not connected 4 Not connected 12 Not connected 5 B signal 13 B signal 6 A signal 14 A signal 7 5V...

Page 40: ...EXT SSC No connection required UCC T3 installation guide www renishaw com Issued 04 2019 40...

Page 41: ...changing removing the air filter The following procedure is recommended when exchanging removing the air filter 1 Remove power from the controller 2 Remove the 19 inch rack mounting brackets if fitted...

Page 42: ...Renishaw address Renishaw plc New Mills Wotton under Edge Gloucestershire GL12 8JR United Kingdom 44 1453 524524 UCC T3 installation guide www renishaw com Issued 04 2019 42...

Page 43: ...nts BG UCC T3 IP30 BS EN60529 1992 2 000 5 C 50 C 25 C 70 C 80 31 C 50 40 C Installation category II 2 UCC T3 IP 40 UCC T3 800 40 C 50 C 400 UCC T3 50 C UCC T3 IEC61010 EN60950 1 UCC T3 installation g...

Page 44: ...hodn nap t Installation category II Stupe zne i t n 2 POZN MKA M e b t zapot eb um stit syst m UCC T3 do vhodn ho elektrick ho krytu podle podm nek prost ed instalace abyste doc lili vy t dy kryt IP P...

Page 45: ...prov d t jak koliv innosti dr by Pokud je za zen pou v no zp sobem kter nen specifikov n v robcem m e doj t ke sn en ochrany poskytovan za zen m Bezpe nostn syst m pro nouzov zastaven zabudovan do di...

Page 46: ...nde jordforbindelse Ansvaret for bestemmelserne om jordforbindelse og fejlstr msbeskyttelse for hele maskinen ligger hos OEM eller installat r Maskinsikkerhed ADVARSEL Slukning eller isolation af UCC...

Page 47: ...rennt Wird eine weitere Abschaltm glichkeit ben tigt ist diese zu spezifizieren und vom Maschinenhersteller oder Installationstechniker f r das Produkt einzubauen Der Trennschalter muss f r den CMM Be...

Page 48: ...tems vorgenommen hat sollte daher eine Angabe enthalten welche Kategorie ben tigt wird Die UCC T3 darf ausschlie lich durch Renishaw Software betrieben werden Die Nichtbeachtung dieser Vorschrift kann...

Page 49: ...aje de sobretensi n Installation category II Nivel de contaminaci n 2 NOTA Dependiendo de las condiciones ambientales de la instalaci n podr a ser necesario ubicar el control UCC T3 en un armario el c...

Page 50: ...ad de la m quina ADVERTENCIA Apagar o aislar el control UCC T3 NO evita necesariamente un movimiento imprevisto de la m quina Para evitar movimientos imprevistos el operario deber desconectar la m qui...

Page 51: ...liti lahti hendamise kaudu Kui esineb vajadus t iendavate isoleerimisviiside j rele tuleb need m ratleda ja paigaldada masina tootjal v i toote paigaldajal Isolaator peab asuma koordinaatm temasina o...

Page 52: ...hk rasiaan asennuspaikan ymp rist n olosuhteiden mukaan paremman IP luokituksen saavuttamiseksi HUOMAA Kun ymp rist n l mp tila on alle 40 C UCC T3 ohjaimen suurin sy tt teho on 800 W L mp tiloissa 40...

Page 53: ...a olla odottamattomia koneen liikkeit FR Recommandations de s curit pour le contr leur UCC T3 Conditions d environnement Utilisation int rieure IP30 BS EN60529 1992 Altitude Jusqu 2 000 m Temp rature...

Page 54: ...one de danger ou de r aliser des op rations de maintenance L utilisation de cet quipement d une mani re non sp cifi e par le constructeur peut compromettre la protection dont cet quipement est pourvu...

Page 55: ...on mheais n ioml n S bh ilteacht mheais n RABHADH T seans ann NACH gcoiscfear gluaiseacht an mheais n gan choinne tr d an UCC T3 a mh chadh n a aonr Moltar don s ideoir an meais n a aonr n sol thar le...

Page 56: ...g akkor azt a berendez s gy rt j nak vagy a term k beszerel j nek kell meghat roznia s beszerelnie A lev laszt nak a CMM zemeltet sz m ra k nnyen hozz f rhet helyen kell lennie s meg kell felelnie az...

Page 57: ...C e 50 C la potenza massima 400 W AVVERTENZA Si sconsiglia l utilizzo del controllo UCC T3 in ambienti con temperature superiori a 50 C AVVERTENZA La responsabilit di eseguire la messa a terra dell in...

Page 58: ...a la categoria richiesta La messa in funzione del controllo UCC T3 deve avvenire solo tramite il software Renishaw In caso contrario la macchina potrebbe non funzionare o generare spostamenti imprevis...

Page 59: ...kokius technin s prie i ros darbus Jei ranga naudojama ne taip kaip nurodo gamintojas gali suma ti rangos teikiama apsauga UCC T3 valdiklyje integruota avarinio sustabdymo saugos sistema pagal BS EN I...

Page 60: ...u visas ier ces zem anu un p r j s pretk mju aizsardz bas uzst d anu ir atbild gs t s ra ot js vai uzst d t js Ier ces dro ba BR DIN JUMS UCC T3 izsl g ana vai atvieno ana NEGARANT to ka ier ce neuzs...

Page 61: ...muntati mill operatur tal magna jew mill installatur tal prodott L i olatur irid jitpo a fejn ikun jista jintla aq fa ilment mill operatur tas CMM u jrid ikun konformi ma IEC61010 u ma kwalunkwe regol...

Page 62: ...der de 40 C is het maximale ingangsvermogen van de UCC T3 800 W Bij temperaturen tussen 40 C en 50 C bedraagt het maximale vermogen 400 W WAARSCHUWING De UCC T3 wordt niet aanbevolen voor toepassing b...

Page 63: ...chinebewegingen voordoen PL Zalecenia dotycz ce bezpiecze stwa dla sterownika UCC T3 Warunki rodowiskowe Urz dzenie przeznaczone do u ytkowania w pomieszczeniach Stopie ochrony IP30 BS EN60529 1992 Wy...

Page 64: ...aniem jakichkolwiek czynno ci konserwacyjnych u ytkownik odizolowa maszyn od zasilania pr dem elektrycznym spr onym powietrzem b d od innych r de energii zgodnie z zaleceniami producenta maszyny Je el...

Page 65: ...e incorpore um condutor terra O aterramento e a prote o contra falha residual da m quina completa s o de responsabilidade do OEM ou instalador Seguran a da m quina ATEN O O desligamento ou o isolament...

Page 66: ...acestea trebuie specificate i instalate de c tre produc torul sau instalatorul ma inii Comanda izola iei trebuie pozi ionat la ndem na operatorului si trebuie sa fie comform cu IEC61010 i cu normele n...

Page 67: ...ky UCC T3 800 W Pre teploty od 40 C do 50 C je maxim lny pr kon 400 W V STRAHA Jednotku UCC T3 sa neodpor a pou va pri okolit ch teplot ch nad 50 C V STRAHA Uzemnenie cel ho pr stroja je zodpovednos o...

Page 68: ...do prev dzky iba prostredn ctvom softv ru od spolo nosti Renishaw inak to m e sp sobi neo ak van pohyb pr stroja SL Varnostna priporo ila za krmilnik UCC T3 Okoljski pogoji Uporaba v zaprtih prostorih...

Page 69: ...nevarno obmo je ali se loti vzdr evalnih del Druga na uporaba opreme kot jo je predpisal proizvajalec lahko povzro i izpad za itnih funkcij opreme Varnostni sistem za zaustavitev v sili ki je integrir...

Page 70: ...dsledare Hela maskinen m ste jordas och jordfelsbrytare installeras detta ansvar ligger terf rs ljaren eller installat ren Maskins kerhet VARNING ven om UCC T3 st ngs av eller kopplas fr n s kan ND ov...

Page 71: ...ails please visit our main website at www renishaw com contact Renishaw plc New Mills Wotton under Edge Gloucestershire GL12 8JR United Kingdom T 44 0 1453 524524 F 44 0 1453 524901 www renishaw com c...

Reviews: