15
1
8
9
23
TONiC RSLM20/RELM20 Functional Safety installation guide and safety manual Original instructions
TONiC Ti interface drawing
Dimensions and tolerances in mm
TONiC DOP interface drawing
Dimensions and tolerances in mm
16
4-40 UNC × 2
40
62
67
CAL/AGC push-button switch
access hole Ø2.4
33.3
8
Cover plate
CAL/Calibration button operation
Push and release (<3 seconds) – CAL routine enable/disable.
Push and release (>3 seconds) – AGC enable/disable.
Push and hold during power ‘Off/On’ cycle – Restore factory defaults.
Refer to readhead LED functionality chart for set-up LED indications.
48
32
9
12.4
Cable exit
Access hatch for readhead
cable connection
Calibration button
PORT NOT
CONNECTED
Set-up LED
15
53
Ø3.5 Clearance holes for M3 cap
screws and star washers or alternative
Mounting for 35 mm
DIN
rail (EN 50022)
21
36
3
7
14.2
37.3
85
93.5
21
4-40 UNC
hex
stand-off 2 positions
Output
26-way
high-density
D-type plug
33.3
2.8
(0.11 inch)
External earthing tag
8.7
10
59.3