Remove cover to replace exhausted battery
1.
Slacken screws (1) and remove battery
cover (2).
2.
Remove battery (3).
Do not remove second cover,
to change battery.
Probe/shank mounting and stylus on-centre
adjustment - remove second cover
3.
Remove screw (4) and battery cover (5).
To replace battery covers
4.
Check that battery cover seals are seated,
and lubricate seals lightly with a mineral
oil or grease.
5.
Replace cover (5) - with Renishaw logo.
6.
Replace battery with polarity as shown
on label,
7.
Replace battery cover (1)
(with battery symbol).
Tighten battery cover screws to
1,1 Nm (0.8 lbf.ft).
Probe battery
Power for the probe is supplied
by one PP3 9V alkaline or lithium
battery. It is essential to select the
type listed in chart, or equivalent.
Low battery warning
When the MI 16 Low Battery
LED lights up, battery voltage
is low and the end of
useable battery life is approaching. (The Low
Battery LED will only light up during the probe
operating mode).
The machine control may also be programmed
to flag up a Low Battery Alarm.
Typical battery reserve life
Using an alkaline battery at 5% usage, the probe
will typically continue to operate for 8 hours, after
the MI 16 Low Battery LED lights up.
Dead battery indication
When the battery voltage drops below the
threshold where performance can be
guaranteed, a probe output relay will also
be forced into its open state, causing the
machine to stop, until a new battery is
inserted. The probe will revert to the
stand-by mode after changing the battery.
TYPICAL BATTERY LIFE EXPECTANCY
BATTERY
(5)
Battery
cover
Battery
cover
(2)
(4)
Screw
2,5mm AF
Cover seal
(3)
Type PP3 9V
battery
(1)
Screw
IMPORTANT
Insert battery as shown
on label
DO NOT leave exhausted
battery in probe
Dispose of exhausted
batteries in accordance
with local regulations
BATTERY
TYPE
Alkaline PP3
MN1604 (Duracell)
Lithium PP3
U9VL-FP
Stand-by
365 days
730 days
5% usage
(72 min/day)
31 days
64 days
Continuous
38 hours
80 hours