FS100B044SX-40NX001X
FORTiS S ML440mm / 1mm / 13RT73
2018 MADE IN UK GL12 8JR
www.renishaw.com
FORTiS-S™
73QR91
FORTiS-S™
73QR91
12
Original instructions
11.4 FORTiS-S FS system installation drawings
B
D
D
D
6
9
85
62
D
C
L
S
D
13
9
7
36
100 typ
H
‘A’ alignment
pin
(optional)
∅
6.8 hole
thru typ
H
H
H
H
H1
H2 H3
2 ±0.1
2 ±0.2
B
0.1
//
X
0.1 CZ
//
X
0.1 CZ
//
B
0.1 CZ
//
35
10.5
25
90
107
ML
40
19.5
37
76
5
23.2
25
ML + 96
(Either end)
Cable connection (either end)
2 ×
∅
6.6 hole thru typ
(Either end)
X
0.1
//
0.05
A = Recommended extrusion alignment pin locations (if required)
Adjacent to first and last flexure holes plus every 300–500 mm
C = Compressed air inlet fitting
D = Required mounting dimensions
H = Flexure mounting holes
H1 = Fixed mounting hole (preferred)
H2 and H3 = Alternative mounting holes (non-preferred)
L = LED set-up illumination
ML = Measuring length
S = Start of measuring length
X = Machine guideway/axis datum
Dimensions and tolerances in mm
59.8
ML + 123
4 × M5 × 0.8
5
KEY