10
Connecting the APC to an HSI interface and the CNC
Controller connector (12-way)
1 0 V
2 Inhibit return
4 External LED 0 V
5 External LED 10 V
6 NO
7 Common
10 Screen
11 Supply 0 V
12 Supply 12 V – 30 V
8 NC
Power
input
9 12 V – 30 V out (fused 100 mA)
3 Inhibit
Standard probe connector (3-way)
1 Probe Input +
2 Probe Input –
3 Screen
CNC
Probe
input
Controller protective earth
(also referred to as PE star
point or earth plate)
Screen
0 Vdc
12 Vdc – 30 Vdc
Controller reference ground
HSI interface
Machine tool
APC
Status
Normally
open
(NO)
Normally
closed
(NC)
Probe
triggered
Closed
Open
Probe
seated
Open
Closed
NOTES:
When the APC is not being used,
it is recommended that the inhibit
function is enabled. The retract
confirm output could be used to
set the inhibit function (for more
information see “Probe inhibit
function” on page 12).
When connecting the APC to the
HSI interface, use the connection
labelled STANDARD PROBE.
Connect either pin 6 or pin 8, but
do not connect both wires.
Status
output
SSR
2
4
1
5
3
Pin
APC connections
2
Retract confirm sensor
4
Probe input +
1
Probe input –
5
Supply 0 V
3
Supply 12 V – 30 V
Retract confirm input
Probe inhibit
function
Summary of Contents for APCA 45
Page 4: ...This page is intentionally left blank...
Page 14: ...APC HSI HSI C 76 dB A x Before you begin continued...
Page 32: ...18 Pneumatic set up continued APCA with air bleed circuit 2 Bulkhead V3 V2 V1...
Page 34: ...20 Bulkhead V2 V1 APCS with air bleed circuit 3 Pneumatic set up continued...
Page 50: ......
Page 51: ......