RMP400 installation guide
2.8
RMP400 basics
RMP400 specification
Principal application
Workpiece inspection and job set-up on multi-tasking machines,
machining centres and gantry machining centres.
Dimensions
Length
Diameter
50.5 mm (1.99 in)
40 mm (1.57 in)
Weight (without shank)
With batteries
Without batteries
262 g (9.24 oz)
242 g (8.54 oz)
Transmission type
Frequency hopping spread spectrum (FHSS) radio
Radio frequency
2400 MHz to 2483.5 MHz
Switch-on methods
Radio M-code or spin on
Switch-off methods
Radio M-code, timer or spin off
Probe feedrate (m
in
imum)
3 mm/min (0.12 in/min) with auto-reset
1
Spindle speed (maximum)
1000 r/min
Operating range
Up to 15 m (49.2 ft)
Receiver/interface
RMI or RMI-Q combined interface and receiver unit
Sense directions
±X, ±Y, +Z
Unidirectional repeatability
0.25 µm (10 µin) 2
s
– 50 mm stylus length
2
0.35 µm (14 µin) 2
s
– 100 mm stylus length
X, Y (2D) form measurement
deviation
±0.25 µm (10 µin) 2
s
– 50 mm stylus length
2
±0.25 µm (10 µin) 2
s
– 100 mm stylus length
X, Y, Z (3D) form
measurement deviation
±1.00 µm (40 µin) 2
s
– 50 mm stylus length
2
±1.75 µm (70 µin) 2
s
– 100 mm stylus length
Stylus trigger force
3 and 4
XY plane (typical minimum)
+Z plane (typical minimum)
0.09 N, 9 gf (0.32 ozf)
3.34 N, 341 gf (12.01 ozf)
Stylus overtravel force
XY plane (typical minimum)
+Z plane (typical minimum)
1.04 N, 106 gf (3.74 ozf)
5
5.50 N, 561 gf (19.78 ozf)
6
Stylus overtravel
XY plane
+Z plane
±11°
6 mm (0.23 in)
1
Speeds below 3 mm/min commonly occur when manually moving the probe using the handwheel with a very fine
feedrate.
2
Performance specification is tested at a standard test velocity of 240 mm/min (9.45 in/min) with a 50 mm (1.97 in)
carbon fibre stylus. Significantly higher velocity is possible depending on application requirements.
3
Trigger force, which is critical in some applications, is the force exerted on the component by the stylus when the
probe triggers. The maximum force applied will occur after the trigger point (overtravel). The force value depends
on related variables including measuring speed, machine deceleration and latency.
RENGAGE equipped probes offer ultra-low trigger forces.
4
These are the factory settings; manual adjustment is not possible.
5
Stylus overtravel force in the XY plane occurs 70 μm (2755.91 µin) after the trigger point and rises by 0.1 N/mm,
10 gf/mm (9.1 ozf/in) until the machine tool stops (in the high force direction and using a 50 mm (1.97 in) carbon
fibre stylus).
6
Stylus overtravel force in +Z direction occurs 1.0 μm (39.37 μin) after the trigger point and rises by 0.6 N/mm,
61 gf/mm (54.8 oz/in) until the machine tool stops.