4.7
Trig
g
er Logic
Stop triggering here, unless “
Multiple probe
mode
” is required, in which case deflect the
stylus for more than 4 seconds.
If no changes are made in “
Multiple probe mode
”, deflecting the stylus for more
than 4 seconds will return the probe settings to beginning of the Trigger Logic
menu. If “
Multiple probe mode
” is selected, proceed to “
Partnering mode
” to
repartner one probe with the RMI or RMI-Q.
Multiple probe mode
(omitted for
“Radio on”
)
(see
“Multiple probe mode settings”
to view all 16 choices)
Mode off
Mode on
Machine 1
Machine 2
Machine 16
Hibernation mode
(only for
“Radio on”
)
On
30 s
On
5 s
Off
Switch-off method
Radio off or
Spin off
Short
timeout
12 s
Medium
timeout
33 s
Long
timeout
134 s
Enhanced trigger filter setting and auto-reset facility
Auto reset off
Trigger filter
on 8 ms
Auto reset off
Trigger filter
on 16 ms
Auto reset on
Trigger filter
on 8 ms
Auto reset on
Trigger filter
on 16 ms
Auto reset off
Trigger filter
off
Acquisition mode
Acquisition mode off
Acquisition mode on
120 seconds probe
in standby
After 8 seconds
Acquisition successful,
20 seconds
probe in standby