23
INSTALLATION MANUAL FOR MODEL: GSE IP-195
sPeCIFICATIons
18. Specifications
Model
GSE IP-195
Number of Tubes
24
Length of Tubes
1500 mm
Outer Tube Diameter
Ø47 mm
Tube Thickness
1.6 mm
Tube Thermal Expansion
3.3 x 10¯ 6 ˚C
Absorptive Coating
Graded AI-N / AI
Absorbency
> 92 % (AM 1.5)
Volumetric Capacity
40 Gallons
Emittance
7 % (100 ˚C)
Insulation
Polyurethane, 55 mm
Solar Collecting Area
24 Square Feet (SF)
Vacuum
P < 0.005 Pa
Stagnation Temperature
<220 ˚C
Heat Loss
< 0.08 W/ SF
Tested Pressure
150 PSI
Working Pressure
79 PSI
Tilt Angle
45°
Weight Empty
165 Pounds
Max. Pressure
11 kg or 150 PSI
Inlet and Outlet
1/2 inches
T&P Valve Port
3/4 inches
Reflector
Flat plate diffuse, aluminum
Frame
Aluminum Alloy
Daily Efficiency
>55% ( >42% in winters)
Dimensions
6’8” x 4’9” x 5’3” (W x D x H, for flat roofs)
System Operation Climate
-30°F to 122°F