INSTALLATION MANUAL FOR MODEL: GSE IP-195
16. system Configuration and Monitoring
The mean of checking the system is to check the temperature monitor. The temperature of cold and
hot water is different when the hot water facet is open.
The monitor equipment is powered by battery. The manufacturer of the temperature monitor is P&D COR
-
PORATION (http://www.tandd.co.jp/). The model isR-71Ui. The manual is available at the company website.
sYsTeM ConFIGURATIon
Kitchen
Washer
Bath & Shower
Laundry
M1
V1
V2
V3
V4
V5
City Water
Cold Water
Hot Water
V1:
solar Bypass Valve
Normal operation Position: OFF
V2, V3: solar Isolation Valve
Normal Operation Position: ON
V4, V5: solar drain Valve
Normal Operation Position: OFF
M1:
Mixing Valve
Set temperature 145.4°F or lower
Existing Hot Water Heater
TR-71Ui Temprature Monitor
powered by battery (T1)
Heating Cable
V0