3.2.6 Error detection and alarm
During washing program running, 8 type of error detection is enabled and the platform will start
alarming and begin to run the error processing program if error occur. At this time, the LCD will
display relative error status information. Below table shows the error type and detail information,
especially, the error code is used by washer software but will not be displayed on LCD:
Error type
Description
Error code
Buzzing
Error
release
Preset lid open
The lid is opened during
preset program running
E0
Abnormal Drain Drain over 8 minutes
E1
Abnormal lid
open
At the starting moment of
wash, rinse and spin process,
the lid is open.
E2
Abnormal spin
Spin unbalance happen
E3
Abnormal inlet
Inlet over 20 minutes
E4
20 times
0.5s/0.5s
on off
buzzing in
every 15
minutes
Open and
close lid
one time
3.2.7 Washing stream
The washing stream is defined by the washing motor on / off time cycles, below tables show the
stream option in relative program running, which also is related to the AC power frequency.
Main stream
High
Middle
Low
Balance
stream
50Hz 1.0/0.7 0.8/0.7
0.6/0.6
Memo
60Hz 0.8/0.8 0.6/0.7
0.5/0.6
50Hz /
/
0.7/0.7
Speedy
60Hz /
/
0.6/0.8
50Hz 0.9/0.7 0.7/0.7
0.5/0.6
Child
60Hz 0.8/0.8 0.6/0.7
0.4/0.6
50Hz 1.1/0.8 0.9/0.8
0.6/0.6
Strong
60Hz 0.9/0.8 0.8/0.8
0.5/0.6
50Hz 1.0/0.7 0.8/0.7
0.6/0.6
Standard
60Hz 0.8/0.8 0.6/0.7
0.5/0.6
0.2/0.5