QB-RL78D1A2 In-Circuit Emulator CHAPTER 2 SETUP PROCEDURE
R20UT3110EJ0101 Rev.1.01
Page 22 of 41
Nov 28, 2014
2.3 Mounting and Connecting Connectors
This section describes the methods of connecting the QB-RL78D1A2 and target system.
Make connections with both the QB-RL78D1A2 and target system powered OFF.
The following abbreviations are used in this section:
- NQ: Target connector
- YQ: YQ connector
- EA: Exchange adapter
- MA: Mount adapter
- CA: Check pin adapter
- SA: Space adapter
2.3.1 Mounting NQ to target system
(1) Thinly apply a two-component epoxy adhesive (hardening time at least 30 minutes) to the ends of the four
projections on the base of the NQ and adhere the NQ to the user board (clean the surface of the target system
board using alcohol or the like). If alignment of target system pads to NQ leads is difficult, align them as in (2).
(2) Align by inserting the guide pins for alignment for the NQ (NQGUIDE) through the pin holes on the top of the
NQ. Accessory holes are
φ
1.0 mm non-through holes in two or three places.
(For hole positions, see the particular NQ drawing.)
(3) Solder after fitting the MA to the NQ. This is to prevent troubles such as flux or solder splashing and adhering
to the NQ contact pins when soldering.
- Soldering conditions Solder reflow
260°C
×
10 seconds or less
Manual soldering 350°C
×
5 seconds or less (1 pin)
Caution
Do not perform washing by flux immersion or vapor.
(4) Take away the guide pins.
Summary of Contents for QB-RL78D1A2
Page 40: ......
Page 41: ...R20UT3110EJ0101 QB RL78D1A2 In Circuit Emulator User s Manual...