M30870T2-CPE User’s Manual
3. Usage (Emulator Debugger)
REJ10J0766-0400 Rev.4.00 February 16, 2006
3.5 Trace Window
(1) Trace window
1. Opening the trace window
Trace window
The trace window is used to show the results of real-time
trace measurements. It has the following four display
modes:
- Bus
mode
Bus information per cycle can be inspected. The contents
are displayed in order of execution paths.
- Disas data access mixed mode
The executed instruction and the content of the accessed
data can be inspected together. Contents are displayed in
order of the execution paths.
- Disassemble
mode
The execution paths of the executed instructions can be
inspected. The contents are displayed in order of
execution paths.
- Source
mode
The execution paths of the source program can be
inspected.
These modes can be switched over using the respective
toolbar buttons.
The trace window shows the measurement result when a
real-time trace measurement has finished. The trace window
remains blank until the real-time trace measurement in
progress finishes.
Trace window
Clicking this button opens the trace window.
Or you can select “Trace” from “Trace” of “Display” menu
for the same effect.
Page 71 of 102
Summary of Contents for M30870T2-CPE
Page 102: ...M30870T2 CPE User s Manual ...