background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Sales Strategic Planning Div.    Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan

http://www.renesas.com

Refer to "

http://www.renesas.com/en/network

" for the latest and detailed information.

Renesas Technology America, Inc.

450 Holger  Way, San Jose, CA 95134-1368, U.S.A
Tel: <1> (408)  382-7500, Fax: <1> (408)  382-7501

 

Renesas Technology Europe Limited

Dukes Meadow, Millboard Road, Bourne End, Buckinghamshire, SL8 5FH, U.K.
Tel: <44> (1628)  585-100, Fax: <44> (1628)  585-900

Renesas Technology (Shanghai) Co., 

Ltd.

Unit 205, AZIA Center, No.133 Yincheng Rd (n), Pudong District, Shanghai 200120, China
Tel: <86> (21)  5877-1818, Fax: <86> (21)  6887-7898

 

Renesas Technology Hong Kong Ltd.

7th Floor, North Tower, World Finance Centre, Harbour City, 1 Canton Road, Tsimshatsui, Kowloon, Hong Kong   
Tel: <852> 2265-6688, Fax: <852> 2730-6071

Renesas Technology Taiwan Co., 

Ltd.

10th Floor, No.99, Fushing North Road, Taipei, Taiwan
Tel: <886> (2)  2715-2888, Fax: <886> (2)  2713-2999

 

Renesas Technology Singapore Pte. Ltd.

1 Harbour Front Avenue, #06-10, Keppel Bay Tower, Singapore 098632 
Tel: <65> 6213-0200, Fax: <65> 6278-8001

Renesas Technology Korea Co., Ltd.

Kukje Center Bldg. 18th Fl., 191, 2-ka, Hangang-ro, Yongsan-ku, Seoul 140-702, Korea

Tel: <82> (2)  796-3115, Fax: <82> (2)  796-2145

 

Renesas Technology Malaysia Sdn. Bhd

Unit 906, Block B, Menara Amcorp, Amcorp Trade Centre, No.18, Jalan Persiaran Barat, 46050 Petaling Jaya, Selangor Darul Ehsan, Malaysia
Tel: <603> 7955-9390, Fax: <603> 7955-9510

RENESAS SALES OFFICES

Colophon 5.0

 

Summary of Contents for H8SX/1653

Page 1: ...SX 1653 Group E6000H TFP 120 User System Interface Board HS1653ECN61H User s Manual Renesas Microcomputer Development Environment System HS1653ECN61HE Revision Date Dec 09 2005 Rev 2 00 REJ10B0200 020...

Page 2: ......

Page 3: ...fore making a final decision on the applicability of the information and products Renesas Technology Corp assumes no responsibility for any damage liability or other loss resulting from the informatio...

Page 4: ......

Page 5: ...er system interface board must only be used for the above purpose Improvement Policy Renesas Technology Corp including its subsidiaries hereafter collectively referred to as Renesas pursues a policy o...

Page 6: ...om you Renesas is not liable for any claim made by a third party or made by you for a third party DISCLAIMER RENESAS MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED ORAL OR WRITTEN EXCEPT AS PROVIDED HE...

Page 7: ...rt may be reproduced or duplicated in any form in hard copy or machine readable form by any means available without Renesas prior written consent Other Important Things to Keep in Mind 1 Circuitry and...

Page 8: ...low this symbol to avoid possible injury or death DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a pote...

Page 9: ...n PERSONAL INJURY The USER PROGRAM will be LOST 1 Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance 2 Always switch OFF the E6000H emulator...

Page 10: ...interface board that connects a user system for the H8SX 1653 TFP 120 package to the H8SX 1650 E6000H emulator HS1650EPH60H Emulation of the H8SX 1653 group is only possible when this user system inte...

Page 11: ...Evaluation Chip Board 7 2 3 Connecting User System Interface Board to Evaluation Chip Board 8 2 4 Recommended Dimensions for User System Mount Pad Footprint 10 2 5 Dimensions for Evaluation Chip Board...

Page 12: ...120 package Please make sure you have all of these components when unpacking Evaluation chip board Spacer User system interface board User system IC socket Screws M2 12 mm with flat washers for fasten...

Page 13: ...tem interface board 1 2 IC socket 1 For the TFP 120 package to be mounted on the user system 3 Socket cover 1 For installing a TFP 120 packaged MCU 4 Screw M2 x 12 mm 4 For fastening cable head with f...

Page 14: ...to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST CAUTION 1 Do not connect a 5 V signal to...

Page 15: ...et for a TFP 120 package to the user system Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets Use slightly more solder than the MCU 2 1 3 I...

Page 16: ...tightened too much the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 3 If the emulator does not operate correctly cracks might have occurred in th...

Page 17: ...ce board User system Pin 1 Screws M2 12 mm with flat washers for fastening cable head IC socket IC149 120 043 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Figure 2 Connecting User System Interface...

Page 18: ...rface board is connected to the user system be careful not to apply load Exchange the spacer 2 6MP 10 mm of the evaluation chip board with another spacer 2 6MP 25 mm provided for the user system inter...

Page 19: ...d the emulator product before the USER SYSTEM INTERFACE BOARD is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned 2 The user system inte...

Page 20: ...ector No UCN1 UCN1 UCN2 UCN2 User system interface board Evaluation Chip Board Connector No Board Connector No Evaluation chip board Figure 4 Connecting User System Interface Board to Evaluation Chip...

Page 21: ...stem with an IC socket for a TFP 120 package IC149 120 043 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s m...

Page 22: ...for the evaluation chip board and the user system interface board are shown in figure 6 Unit mm Tolerance 0 5 mm 140 0 Evaluation chip board User system interface board 102 5 16 0 118 5 100 0 84 5 69...

Page 23: ...ser system interface board to the user system are shown in figure 7 Unit mm Tolerance 1 0 mm 35 6 16 0 57 6 User system Evaluation chip board IC socket IC149 120 043 B51 manufactured by YAMAICHI ELECT...

Page 24: ...lt in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST CAUTION When this emulator is used without connecting to th...

Page 25: ...14 P1 SW1 ON USER OFF Figure 8 SW1 Jumper Socket Spacer 2 6MQ x 16 mm Figure 9 Attaching Spacers...

Page 26: ...PM4 VBUS DrVcc DrVcc USD USD USD USD Power supply circuit EPM7128 1 k Figure 10 User System Interface Circuit 1 Note The power supply circuit shown above is turned on off by the setting of the SW1 jum...

Page 27: ...3 P27 P23 P27 SN74CB3Q3306A SN74CB3Q3306A MCU User system Figure 11 User System Interface Circuit 2 MCU User system Sub MCU P14 P14 SN74CB3Q3306A TXD SN74CB3Q3306A Figure 12 User System Interface Circ...

Page 28: ...17 MCU VHC244 UHC14 _RES Vcc User system EPM7128 EPM7128 _RES 47 k Figure 13 User System Interface Circuit 4...

Page 29: ...of clock sources as the MCU clock For details refer to the H8SX 1650 E6000H Emulator User s Manual HS1650EPH60HE To use the emulator internal clock Select the clock in the emulator by the CLOCK comman...

Page 30: ...aluation chip board Install the crystal oscillator into the crystal oscillator terminals on the evaluation chip board Evaluation chip board Crystal oscillator terminals Crystal oscillator Enlarged vie...

Page 31: ...ose of the MCU 4 This user system interface board is specifically designed for the HS1650EPH60H emulator Do not use this board with any other emulator 5 When power is not supplied to the Vcc pin on th...

Page 32: ...terface cable and user system 9 To connect the emulator to the user system ensure that the SW1 jumper pin is inserted to ON Failure to do so will damage the emulator product user system interface boar...

Page 33: ...group when the user system interface board is connected to the emulator 1 The USB clock frequency is fixed to 48 MHz regardless of the EXTAL input 2 P14 cannot be used as a port if the serial output...

Page 34: ...ce Board HS1653ECN61H Publication Date Rev 1 00 November 11 2004 Rev 2 00 December 9 2005 Published by Sales Strategic Planning Div Renesas Technology Corp Edited by Customer Support Department Global...

Page 35: ...esas Technology Hong Kong Ltd 7th Floor North Tower World Finance Centre Harbour City 1 Canton Road Tsimshatsui Kowloon Hong Kong Tel 852 2265 6688 Fax 852 2730 6071 Renesas Technology Taiwan Co Ltd 1...

Page 36: ...2 6 2 Ote machi Chiyoda ku Tokyo 100 0004 Japan H8SX 1653 Group E6000H TFP 120 User System Interface Board HS1653ECN61H User s Manual...

Reviews: