background image

5

Section 2   Connection Procedures

WARNING

Always switch OFF the user system and the emulator

product before the EXPANSION I/O BOARD or USER
SYSTEM INTERFACE CABLE is connected to or removed
from any part. Before connecting, make sure that pin 1 on
each side is correctly aligned.  Failure to do so will result in
a FIRE HAZARD and will damage the user system, the
emulator product, the user system interface cable, and the
expansion board, or will result in PERSONAL INJURY.  The
USER PROGRAM will be LOST.

2.1

Using Emulator without Connecting User System

1. Make sure the emulator is turned off.

2. After making sure the direction of the expansion I/O board connector labeled E6000

EMULATOR is correct, firmly insert the expansion I/O board connector into the emulator
station connector. When the emulator is operated while connected to only the expansion I/O
board (without connecting the user system), disconnect the cable body from the expansion I/O
board.

Summary of Contents for H8/36024

Page 1: ...ok over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electron...

Page 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Page 3: ...36024 H8 36049 Group Expansion I O Board for E6000 Emulator User s Manual User s Manual Rev 1 0 2003 12 HS36024EIO61HE Renesas Microcomputer Development Environment System H8 Family H8 300H Tiny Seri...

Page 4: ...described here may contain technical inaccuracies or typographical errors Renesas Technology Corp assumes no responsibility for any damage liability or other loss rising from these inaccuracies or err...

Page 5: ...n to be connected to the user system interface cable This expansion I O board must only be used for the above purpose Improvement Policy Renesas Technology Corp including its subsidiaries hereafter co...

Page 6: ...urchases the emulator product from you Renesas is not liable for any claim made by a third party or made by you for a third party DISCLAIMER RENESAS MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED ORAL...

Page 7: ...t may be reproduced or duplicated in any form in hard copy or machine readable form by any means available without Renesas s prior written consent Other Important Things to Keep in Mind 1 Circuitry an...

Page 8: ...mbol to avoid possible injury or death DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potentially haz...

Page 9: ...r remodel the emulator product by yourself for electric shock prevention and quality assurance 2 Always switch OFF the E6000 emulator and user system before connecting or disconnecting any CABLES or P...

Page 10: ...referred to as the expansion I O board for the H8 36024 H8 36049 group E6000 emulator The expansion I O board enables user systems for Renesas s original microcomputer H8 36024 H8 36049 group to be d...

Page 11: ...e Cables 2 1 3 Operating Voltage and Frequency Specifications 3 1 4 Components 4 Section 2 Connection Procedures 5 2 1 Using Emulator without Connecting User System 5 2 2 Using Emulator with Connectin...

Page 12: ...3 The expansion I O board should be used with H8 36024 H8 36049 group E6000 emulator station HS3664EPI61H hereinafter referred to as the emulator 1 1 Environment Conditions Table 1 1 Environment Cond...

Page 13: ...pported by the E6000 H8 36024 H8 36049 group Table 1 2 H8 36024 H8 36049 group MCUs and User System Interface Cable No MCU Type Number Package E6000 User System Interface Cables 1 HD64F36024 HD64F3602...

Page 14: ...erating voltage range and operating frequency range guaranteed for the MCU operation normal emulator operation is not guaranteed Table 1 3 Operating Voltage and Frequency Specifications No MCU Types O...

Page 15: ...board Please make sure you have all of these components when unpacking USER INTERFACE CABLE E 6 0 0 0 E M U L A T O R E 6 0 0 0 Figure 1 1 HS36024EIO61H Expansion I O Board Table 1 4 HS36024EIO61H Co...

Page 16: ...duct the user system interface cable and the expansion board or will result in PERSONAL INJURY The USER PROGRAM will be LOST 2 1 Using Emulator without Connecting User System 1 Make sure the emulator...

Page 17: ...twist the cable or connectors Otherwise the cables or connectors will be damaged 1 Make sure the emulator and the user system are turned off 2 1 After making sure the direction of the expansion I O bo...

Page 18: ...d 1 E 6 0 0 0 USER INTERFACE CABLE E 6 0 0 0 E M U L A T O R E 6 0 0 0 2 Cable body connector User system interface cable CTS screws M3 x 6 mm Figure 2 1 Connecting Expansion I O Board to Emulator Sta...

Page 19: ...expansion I O board Signals are connected to the user system interface cable with the protection circuit Figure 3 1 shows user system interface circuit E6000 HS3664EPI61H H8 3664 HS36024EIO61H User sy...

Page 20: ...the HS3664EPI61H Do not use this expansion I O board with any other emulator station 2 Use the H8 36014 and H8 36024 group user system interface cable HS36014ECH61H for FP 64E HS36014ECH63H for FP 48F...

Page 21: ...ual Publication Date Rev 1 00 December 19 2003 Published by Sales Strategic Planning Div Renesas Technology Corp Edited by Technical Documentation Information Department Renesas Kodaira Semiconductor...

Page 22: ...1753 Shimonumabe Nakahara ku Kawasaki shi Kanagawa 211 8668 Japan H8 36024 H8 36049 Group Expansion I O Board for E6000 Emulator REJ10B0095 0100H User s Manual...