Notes: 1. If the user system interface cable is disconnected from the connector on the user
system, the following dialog box will appear.
Figure 3.19 [Connector disconnected] Dialog Box
2. If the emulator is not properly initialized, one of the dialog boxes shown in figures 3.20
through 3.24 will appear.
(a)
The following dialog box is displayed when the flash memory cannot be erased.
Exchange the MCU since the flash memory has been programmed more times than
the limitation.
Figure 3.20 [Flash memory erase error!] Dialog Box
(b)
The following dialog box is displayed when the flash memory cannot be programmed.
An incorrect system clock value has been input or the flash memory has been
programmed more times than the limitation.
Figure 3.21 [Error sending Flash memory write program] Dialog Box
33