2.8.5 Connecting to a 100-pin 0.65mm Pitch Foot Pattern (Part 3)
Figure 2.13 shows how to connect a 100-pin 0.65mm pitch foot pattern on the user system to the M3T-DUMMY100S (not
included), and here following is its procedure. For details on the M3T-100LCC-DMS (not included) and M3T-DUMMY100S
(not included), refer to each user's manual.
(1) Attach the M3T-DUMMY100S to the user system.
(2)
Attach the M3T-100LCC-DMS to the M3T-DUMMY100S.
(3)
Attach the CN2 side of the M30800T-PTC to the CN2 side of the package converter board connected to the emulation pod
probe.
(4) Attach the M30800T-PTC to the M3T-100LCC-DMS.
Figure 2.13 Connecting to a 100-pin 0.65mm pitch foot pattern (3/3)
CAUTION
Note on Connecting the User System:
z
Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulation
pod.
IMPORTANT
Notes on Connectors of the Converter board:
z
The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal iterations.
z
The connectors of the M3T-100LCC-DMS and M3T-DUMMY100S are guaranteed for only 20
insertion/removal iterations.
M3T-100LCC-DMS
(not included)
CN2 side
(3)
(4)
M30800T-PTC
(2)
FLASH MCU, etc.
On-board evaluation
M3T-DUMMY100S
(not included)
(1)
100-pin 0.65mm pitch
(PRQP0100JB-A) foot pattern
No. 1 pin
User system
Package converter board
Tip of emulation pod probe