14
TECHNICAL DATA
R
888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com
Control Settings—RB5C7748R
Mechanical Settings
Pressure Settings – S/Contained
Differental
60
High Side Cut-In
260
Superheat
8-10
Control Settings
Set Point (Supply Air)
SP
27
Maximum Defrost Duration
dd
45
Hysteresis
HY
4
Dripping Time
dC
5
Low Setup Stop
LL
20
First Defrost After Power On
dU
OF
High Setup Stop
HL
50
Display During Defrost
dP
0
Anti-Short Cycle Delay
CC
3
Display Delay After Defrost
dr
20
Deep Freezing Time
Co 0
60
Digital Input Function
iF
0
High Temperature Alarm
AH
15
Digital Input Time Delay
id
10
Low Temperature Alarm
AL
-10
Fan Operating Function
FF
0
Alarm Differential
Ad
5
Fan Startup Delay (After Defrost)
Fd
0
Alarm Time Delay
At
30
Fan Startup Temperature After Defrost End
Fr
40
Defrost Type
dF
0
Sensor Failure Operation
SF
2
Defrost End Mode
dE
0
Temperature Sensor Offset
So
0
Defrost Termination Temperature
dt
45
Temperature Units Used
Un
1
Defrost Interval
di
6
Display Refresh Rate
PU
1
Electronic Controller
Mechanical