CUSTOMER PREPARATIONS BEFORE INSTALLATION
• Partitions around the device location should be at least 5 cm if they are made
of non-combustible material, otherwise at least 20 cm.
• Attention should be paid to fire protection rules.
• Before calling our technical service for installation, the necessary gas
installation must be available at the place where the assembly of the device will
be made.
ASSEMBLY
• The ground on which the device will be placed must be smooth and level. If the
counter will be placed on a bench, the legs of the bench should be adjustable
and the balance balance should be provided. Care should be taken to ensure
that the upper surface of the counter is made of non-flammable material.
• Before installation, safety details and suitability of installation conditions
should be checked.
• The gas connection is made to the device, paying attention that the installation
is in accordance with the gas type and pressure specified on the label on the
device. Installation should never be made to a different installation than the
information on the device.
• Connection entry dimensions are specified on the technical specifications
page.
• After the device is assembled, it is operated and its burning is controlled. If
necessary, air adjustment is made to prevent soot burning and to ensure ideal
combustion.
• After the assembly is completed, gas tightness should be checked with soap
bubbles.
• No changes can be made to the injector and valves that will take out of the
rated power in the device.
• The use of parts other than original parts is out of warranty.