Restoring Factory Defaults

All Configuration Parameters can be restored to their factory 
default settings by using your primary controller to reset the 
device. (Delete device from the network)

WIRELESS INFORMATION

Wireless range:

This device has an open-air line-of-sight transmission distance of 
25m which complies with the Z-Wave standards. Performance 
can vary depending on the amount of objects in between Z-Wave 
devices such as walls and furniture. Every Z-Wave device set up 
in your network will act as a signal repeater allowing devices to 
talk to each other and find alternate routes in the case of a 
reception dead spot.
Radio frequency limitations:
1. Each wall or object (i.e.: refrigerator, bookshelf, large TV, etc) 

can reduce the maximum range of 65 feet by up to 25 to 30%.

2. Plasterboard and wooden walls block less of the radio signal 

then concrete, brick or tile walls which will have more of an 
effect on signal strength.

3. Wall mounted Z-Wave devices will also suffer a loss of range 

if they are housed in metal junction boxes which could also 
reduce the range by up to 25 to 30%.

MAINTENANCE

1. Do not expose your ZFM-80US to dust, strong sunlight, 

humidity, high temperatures or mechanical shocks.

2. Do not use corrosive or abrasive cleansers on your ZFM-

80US.

3. Keep the unit dust free by wiping it with a soft, dry cloth.
4. Do not disassemble your ZFM-80US, it contains no user-

serviceable parts.

TECHNICAL SPECIFICATIONS

Note: Specifications subject to change without notice due to continuing 
product improvement

Certifications

FCC Information
FCC ID : ZGIDA065
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including 

interference that may cause undesired operation.

Warning:

 

Changes or modifications to this unit not expressly approved by 
the party responsible for compliance could void the user authority 
to operate the equipment.

NOTE: 

This equipment has been tested and found to comply with the 
limits for a Class B digital device, pursuant to Part 15 of the FCC 
Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. 
This equipment generates, uses and can radiate radio frequency 
energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio 
communications.
However, there is no guarantee that interference will not occur in 
a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of 
the following measures:
-

Reorient or relocate the receiving antenna.

-

Increase the separation between the equipment and receiver.

-

Connect the equipment into an outlet on a circuit different 
from that to which the receiver is connected.

-

Consult the dealer or an experienced radio/TV technician for 
help.

Model no.

RF frequency

Input voltage

RF operating
distance 

Z-Wave
association group 

Output relay
power rating  

Dimension 

Weight

Storage

Operation
Temperature 

Environment

ZFM-80US / DA065

908.42MHz

120Vac or 230Vac

up to 25m (line of sight between the Wireless 
Controller and the closest Z-Wave receiver module.)

Support 1 association group; 
Each association group contains 5 nodes max.

230Vac 10A max. or 120Vac 15A max. 
(Resistive load)

68(L) x 35(W) x 25(H)mm

50g metal mount excluded; 70g metal mount included

o

-25~60 C

o

-5~45 C

Indoor use only

Configuration Command for "Conditional 

trigger for Fail Safe Installation"

LED Indication Status:

Basic Operation

The connected device can be turned ON in two ways:
1. Manual control with the push button on the ZFM-80US.
2. Z-Wave remote controller.

Manual ON/OFF function

Z-Wave Remote Control

Include or exclude the Fixture Switch Module from the existing Z-
Wave home control network with your primary controller.
-

Refer to your primary controller instructions to process the 
inclusion / exclusion setup procedure.

-

When prompted by your primary controller, click once on the 
PROG button or external switch.

-

The primary controller should indicate that the action was 
successful. If the controller indicates the action was 
unsuccessful, please repeat the procedure.

-

Once the Fixture Switch Module is part of the network, the 
same basic procedure is used to add the Fixture Switch 
Module to groups or scenes. Refer to the primary controller's 
instructions for details.

Support Association Command Class

ZFM-80US support one association group, this association 
group contains 5 nodes max.
It is used to report the relay on/off status to specify nodes with 
ZFM-80US predefined association group once the relay state 
has been changed.

All On/All Off functions

Depending upon your primary controller, the Fixture Switch 
Module can be set to respond to ALL ON and ALL OFF 
commands up to four different ways. Some controllers may not 
be able to change the response from its default setting. Please 
refer to your controller's instructions for information on whether 
or not it supports the configuration function and if so, how to 
change this settings. 
The four possible responses are:
-

It will respond to ALL ON and the ALL OFF commands 
(default).

-

It will not respond to ALL ON and ALL OFF commands.

-

It will respond to the ALL OFF command but will not respond 
to the ALL ON command.

-

It will respond to the ALL ON command but will not respond to 
the ALL OFF command.

Turn the resistive household appliance On/Off by pressing the 
button at front or external switch. 
(Press the external switch to turn the resistive household 
appliance on if it is in off stage and vice versa)

Parameter 

Number

Set timeout period

Configure Node ID 
number for Z-Wave 
command source

Set relay output status if 
timeout period has been 
reached

Definitions

2 (0x02)

3 (0x03)

4 (0x04)

Parameter value range

0 ~ 240 (minutes)
(default value is 0 
[function disabled])

1 ~ 232 (Node ID number)
(default value is 0 
[function disabled])

1 = turn on relay
0 = turn off relay
(default value is 0)

Operations

   LED flashes slowly 
   within 2 seconds then 
   stay on if external 
   switch stay in active 
   stage.
   LED light up.

LED flashes slowly 
within 2 seconds then 
stay on.

LED flashes 2 times 
then stay on.

LED flashes 6 times 
rapidly then stay on.

Device already exist 

in network

ZFM-80US 
power on

Press 
PROG button /
Press 
external switch
(Learning mode)

Receive 
command /
Send command 
or data

Error

Device does NOT exist 

in network

   LED flashes slowly within 
   2 seconds then stay on if 
   external switch stay in 
   active stage.
   LED flashes slowly within 
   4 minutes then stay on if 
   external switch stay in 
   inactive stage.

LED flashes slowly within 
2 seconds then stay on.

N/A

N/A

LED Indication Status

-

-

-

-

BW8330 

TM

(Z-URC  550)

BW8380 
(ZRC- 100)

IC information

IC : 9548A-DA065
This device complies with Industry Canada licence-exempt RSS 
standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2)this device must accept any interference, including 

interference that may cause undesired operation of the 
device.

This device complies with RSS-310 of Industry Canada. 
Operation is subject to the condition that this device does not 
cause harmful interference.

WARNINGS

Do not dispose of electrical appliances as unsorted municipal 
waste, use separate collection facilities. Contact your local 
government for information regarding the collection systems 
available.

RISK OF FIRE

RISK OF ELECTRICAL SHOCK

RISK OF BURNS

DID NOT QUALIFY FOR INSTRUMENT OF MEDICAL AND 

LIFE SUPPORT EQUIPMENT

Z-Wave Fixture Switch Module never got qualified certificate to 
supply power for medical instrument or any life support 
equipment. 

There is no user serviceable parts in the 

Fixture Switch Module. 

  

Please contact a qualified electrician to install this product. Do 
not modify the fixture switch module in any way.

WARRANTY

ONE-YEAR LIMITED WARRANTY: Remotec warrants this 
product to be free from defects in materials and workmanship 
under normal use and service for a period of one year from the 
original date of purchase from the distributor or dealer.

REMOTEC shall not be liable for:
-

Damages caused by defective devices for indirect, incidental, 
special, consequential or punitive damages, including, inter 
alia, loss of profits, savings, data, loss of benefits, claims by 
third parties and any property damage or personal injuries 
arising from or related to the use of the device.

-

Service trips to provide instruction on product use.

-

Shipping costs for replacement products.

This warranty is limited to the repair or replacement of this 
product only, if the purchase date cannot be substantiated, the 
warranty period will begin on the date of manufacture as 
indicated on this product. All warranty claims must be made to 
Remotec appointed distributors or dealers during the applicable 
warranty period. This warranty gives you specific legal right and 
you may also have other rights which vary in each country.

F820-8041-0000