
2
Technical data
2.1
Unit data
Series
RBW 300 PV
RBW 300 PV-S
Function
Domestic hot-water heating
System
Air / water heat pump
Drinking water tank enamelled, gross volume
l
Series 300
Drinking water tank enamelled, net volume
l
287
280
Auxiliary heater / rated output
kW
Series / 1.5
Usable limits, heating
°C
-7 to +40
Min./max. Water temperature
°C
38 / 60
Heating capacity with A7/W50
kW
1.8
COP per EN 255-3 / COP with A7/W50
1)
COP
3.7
COP per EN 16147 / COP with A7/W50
1)
COP
2.61
Power supply
V / ~ / Hz
230 / 1/ 50
Electrical rated power consumption
kW
0.46
Max. rated power consumption
kW
2.06
Rated current consumption
A
8.92
Max. current consumption
A
9.0
Refrigerant / basic capacity
-- / kg
134A
2)
/ 0.95
Fuse protection prov. by the customer (p. outdoor unit)
A slow-
acting
16
Sound power level/sound pressure 1m hemispherical
dB(A)
53/45
Max. airflow volume
m³/h
350
Min. flow volume
m³/h
175
Max. operating pressure
bar
7
Air duct connection
mm
145
Hydraulic connection, water-side
Inches
IG 3/4"
Condensate-drain socket
Inches
IG 1/2"
Max. permissible air-side pressure loss
kPa
50
Pipe length supply/exhaust duct max. (at 150 mm)
m
6/6
Dimensions (diameter/height/tilt height)
mm
650/1870/1920
Enclosure class
--
IP X1
Weight
kg
136
141
1)
COP = coefficient of performance (heating capacity figure)
2)
Contains greenhouse gas according to Kyoto protocol, GWP 1975
For technical details regarding the integrated heat exchanger see overleaf.
7
Summary of Contents for RBW 300 PV
Page 9: ...Lid dimensions 620 mm 460 mm 300 mm 150 mm 150 mm 160 mm 400 mm Fig 2 Lid dimensions 9...
Page 45: ...45...
Page 46: ...REMKO RBW 46...
Page 47: ......