2.2 Characteristic curves
0
100
200
300
400
500
600
0
500
1000
1500
2000
2500
3000
3500
2
1
A
B
Fig. 1: Characteristic curves
1: Pressure build-up [Pa]
2: Medium flow rate [m
3
/h]
A: Characteristic curve for the smaller stage
B: Characteristic curve for the higher stage
Measurement carried out per DIN EN ISO 5801 – Test set-up category B.
3
Unit description
The combination of powerful axial fan and well
thought out accessories for connecting air distribu-
tion hoses make the unit a particularly versatile sol-
ution for aeration and ventilation, air circulation and
also for transporting warming air or cooling air over
longer distances.
The unit is also ideally suited to provide effective
support for dehumidifiers when drying buildings.
The rapid air movement breaks up the high
humidity layer on the material and increases the
evaporation rate. This results in walls, ceilings and
floors drying faster! The higher the flow rate on the
damp surface of the material, the faster the drying
process. Thus, the drying time can be drastically
shortened through the combination of dehumidi-
fiers and this powerful fan, depending on the
respective environment and temperature. The use
of additional fans accelerates the evaporation
whereby the drying process can be shortened by
up to 50%.
The unit has hose connection ports on both sides
allowing very versatile use.
The unit is equipped with a 2-speed high-perform-
ance axial fan, operating hours counter, motor
overload protection switch and mains cable with
230 V CEE connector.
The unit conforms to the fundamental health and
safety requirements of the appropriate EU stipula-
tions and is simple to operate.
REMKO RAV
8