1.1  General safety notes

Carefully read the operating manual before com-

missioning the units for the first time. It contains

useful tips and notes such as hazard warnings to

prevent personal injury and material damage.

Failure to follow the directions in this manual not

only presents a danger to people, the environment

and the system itself, but will void any claims for

liability.

Keep this operating manual and the refrigerant

data sheet near to the units.

1.2  Identification of notes

This section provides an overview of all important

safety aspects for proper protection of people and

safe and fault-free operation.The instructions and

safety notes contained within this manual must be

observed in order to prevent accidents, personal

injury and material damage.

Notes attached directly to the units must be

observed in their entirety and be kept in a fully

legible condition.

Safety notes in this manual are indicated by sym-

bols. Safety notes are introduced with signal words

which help to highlight the magnitude of the danger

in question.

 DANGER!

Contact with live parts poses an immediate

danger of death due to electric shock. Damage

to the insulation or individual components may

pose a danger of death.

 DANGER!

This combination of symbol and signal word

warns of a situation in which there is immediate

danger, which if not avoided may be fatal or

cause serious injury.

 WARNING!

This combination of symbol and signal word

warns of a potentially hazardous situation,

which if not avoided may be fatal or cause

serious injury.

 CAUTION!

This combination of symbol and signal word

warns of a potentially hazardous situation,

which if not avoided may cause injury or mate-

rial and environmental damage.

 NOTICE!

This combination of symbol and signal word

warns of a potentially hazardous situation,

which if not avoided may cause material and

environmental damage.

This symbol highlights useful tips and recom-

mendations as well as information for efficient

and fault-free operation.

1.3  Personnel qualifications

Personnel responsible for commissioning, opera-

tion, maintenance, inspection and installation must

be able to demonstrate that they hold a qualifica-

tion which proves their ability to undertake the

work.

1.4  Dangers of failure to observe

the safety notes

Failure to observe the safety notes may pose a risk

to people, the environment and the units. Failure to

observe the safety notes may void any claims for

damages.

In particular, failure to observe the safety notes

may pose the following risks:

n

The failure of important unit functions.

n

The failure of prescribed methods of mainte-

nance and repair.

n

Danger to people on account of electrical and

mechanical effects.

1.5  Safety-conscious working

The safety notes contained in this manual, the

existing national regulations concerning accident

prevention as well as any internal company

working, operating and safety regulations must be

observed.

 

 

 

REMKO RAV

 

 

4

Summary of Contents for RAV 35

Page 1: ...Operating instructions Read the instructions prior to performing any task REMKO RAV 35 High performance fans for the construction and renovation industry 0190 2018 07 Edition 1 en_GB ...

Page 2: ...ead these operating instructions carefully before commis sioning using this device These instructions are an integral part of the system and must always be kept near or on the device Subject to modifications No liability accepted for errors or mis prints ...

Page 3: ...aintenance and inspection work 5 1 8 Unauthorised modification and changes 6 1 9 Intended use 6 1 10 Warranty 6 1 11 Transport and packaging 6 1 12 Environmental protection and recycling 6 2 Technical data 7 2 1 Unit data 7 2 2 Characteristic curves 8 3 Unit description 8 4 Electrical wiring 9 5 Commissioning 9 6 Motor overload protection switch 10 7 Shutdown 10 8 Care and maintenance 11 9 General...

Page 4: ...may be fatal or cause serious injury WARNING This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may be fatal or cause serious injury CAUTION This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may cause injury or mate rial and environmental damage NOTICE This combination of symbol and sig...

Page 5: ...nits must not be covered during opera tion n The units must not be transported while they are running n All electrical cables on the outside of the units must be protected against damage e g by ani mals etc n Wear hearing protection if spending a longer period of time in the vicinity of the unit n The units must be inspected by a service tech nician to ensure that they are safe to use and fully fu...

Page 6: ...certificate of warranty to REMKO GmbH Co KG at the time when the units are purchased and commissioned The warranty conditions are detailed in the Gen eral business and delivery conditions Further more only the parties to a contract can conclude special agreements beyond these conditions In this case contact your contractual partner in the first instance 1 11 Transport and packaging The devices are...

Page 7: ... electrical protection A 10 Max current consumption A 3 2 Sound pressure level 5 m dB A 68 Max temperature of conveyed medium C 40 Hose connection Ø mm 300 Max hose length m 38 Dimensions H W D mm 440 380 420 Weight kg 17 EDP no 1610635 Calculated for solid ball Measurement per DIN EN ISO 9614 2 We reserve the right to modify the dimensions and design as part of the ongoing technical development p...

Page 8: ...dings The rapid air movement breaks up the high humidity layer on the material and increases the evaporation rate This results in walls ceilings and floors drying faster The higher the flow rate on the damp surface of the material the faster the drying process Thus the drying time can be drastically shortened through the combination of dehumidi fiers and this powerful fan depending on the respecti...

Page 9: ...ate feed point with a residual current device in accordance with VDE 0100 Section 55 5 Commissioning Before the initial commissioning n Check that the unit and any accessories being used are installed correctly A B A Example 1 Optional dust bag 1009540 B Example 2 Optional WL hose 1009512 NOTICE Always fasten hoses and dust bag with suitable lashing straps or clamps Commissioning Connect unit n Sw...

Page 10: ...ered the cause of the malfunction must be identified and rectified before a reset is performed 7 Shutdown n Move the operating switch to the 0 position n Read off the operating hours counter if required With longer breaks in operation n Disconnect the unit from the power supply n Clean the unit if required and store in a location protected from dust and direct sunlight The units can be stacked to ...

Page 11: ... socket Cleaning the units n The units should be disconnected from the electrical power supply and secured to prevent unauthorised reactivation n Clean the intake grill at regular intervals and replace it if damaged n Clean all intake openings and discharge fins n To clean the fan blades it is necessary to remove the protection grid beforehand n Clean severe soiling on the fan and the fan housing ...

Page 12: ...9 2 Cable gland 1122990 3 Metal grill 1122991 4 Hose connection ports 1122992 5 Fan housing 1113039 6 Control panel 1122995 7 Operating hours counter 1113048 8 Reset button 1122997 9 12 µF capacitor 1122998 10 5 µF capacitor 1122999 11 Operating switch 1122996 12 Electric motor 1122993 13 Fan blade 1122994 To assure the correct delivery of spare parts please always provide the unit type with its c...

Page 13: ...ection switch 10 O Ordering spare parts 12 S Safety Dangers of failure to observe the safety notes 4 General 4 Identification of notes 4 Instructions for the operator 5 Note for inspection work 5 Note for installation work 5 Note for maintenance work 5 Personnel qualifications 4 Safety conscious working 4 Unauthorised modification 6 Unauthorised replacement part manufacture 6 Shutdown 10 Spare par...

Page 14: ...REMKO RAV 14 ...

Page 15: ......

Page 16: ...ct as advisers to our customers in air conditioning and heating technology SFlbCustomer Service Our equipment operates precisely and reliably However in the event of a fault REMKO customer service is quickly at the scene Our comprehensive network of experienced dealers always guarantees quick and reliable service REMKO INTERNATIONAL and also right in your neighbourhood Make use of our experience a...