NOTE

Operation for any other pur-
pose than that described in 
these operating instructions 
is not permitted. Failure to 
observe this requirement will 
result in all liability being 
disclaimed and the warranty 
rendered invalid.

Customer service and 
warranty

A precondition for any warran-
ty claims is that the dealer or his 
customer has completed and 
returned the enclosed 

“Warranty 

document“

 to REMKO GmbH & 

Co. KG at the time of sale and 
commissioning. 

The units were repeatedly tested 
for perfect functioning at the 
factory.  
If problems should occur which 
cannot be remedied by trouble-
shooting by the operator, your 
specialised dealer or contract part-
ner should be contacted.

Intended use

Disposal of packaging

When disposing of the packaging 
material, please think of the envi-
ronment. 
Our units are carefully packed for 
transport and delivered in sturdy 
cardboard packaging on a wooden 
pallet, if necessary.
The packaging materials are 
environmentally-friendly and can 
be recycled.
By reusing packaging materials, 
you make a valuable contribution 
towards waste reduction and the 
conservation of raw materials.

Only dispose of packaging materi-
al at the facilities provided.

Disposal of old unit

 

The production of our units is sub-
ject to constant quality controls.

Only high-quality materials are 
used, the majority of which are 
recyclable.

Make your contribution towards 
environmental protection by dispo-
sing of your old unit in an environ-
mentally-friendly manner.

Only dispose of your old unit at 
an authorised recycling facility or 
similar.

NOTE

Adjustments and maintenance 
must only be carried out by 
authorised specialists.

Environmental 

protection and 

recycling

ATTENTION

Copyright

Any copying of this docu-

ment in whole or part or use 

for purposes other than the 

intended is strictly forbidden 

without the prior written 

permission of  

REMKO GmbH & Co.

 KG

.

Due to their design and equip-
ment, the units are intended solely 
for heating and cooling purposes 
in industrial or commercial use. 

The units must only be operated 
by suitably trained personnel. 

The manufacturer disclaims all 
liability for any damage attributed 
to failure to observe relevant in-
structions, statutory requirements 
applicable at the place of use or 
unauthorised changes to the unit.

Summary of Contents for PWL 101-3

Page 1: ...Edition GB Vo6 REMKO PWL Ceiling mounted air unit Heating Cooling Operation Technology Spare parts...

Page 2: ......

Page 3: ...ta PWL 201 203 16 Rating tables Technical data PWL 301 303 18 Intended use 20 Customer service and warranty 20 Environmental protection and recycling 20 Exploded view 21 Spare parts list 21 Legend Ope...

Page 4: ...s length width height Required air change Required room temperature Required heating medium tem perature for flow and return The air inlet temperature of the units should not be below 34 C and not abo...

Page 5: ...r removal of the produced condensate in cooling operation a ready to connect condensate pump is provided For an optimal air flow individually adjustable louvres are provided at the top of the housing...

Page 6: ...o an air outlet temperature of 8K below room temperature and ideal prima ry air flow conditions Maximum mounting heights and operating limits The maximum mounting heights depend on the maximum range a...

Page 7: ...using This prevents persons being expo sed to a direct air stream Rooms with low ceilings horizontal blowing direction Rooms with low ceilings horizontal blowing direction Rooms with high ceilings ver...

Page 8: ...day night control etc can always be connected per control unit Terminals in the unit Fuse protection in the supply to the control unit must be in compli ance with the applicable regulati ons The conn...

Page 9: ...tion To prevent frost damage anti frost protection must be provided at temperatures below 0 C Where systems in rooms at risk from frost are not used for ex tended periods under no circum stances must...

Page 10: ...ool down Cleaning the units The surfaces of the units must be cleaned only dry or with a moist cloth and a small amount of soap solution if necessary Under no circumstances use high pressure cleaners...

Page 11: ...hydraulic con nection 4 Remove the bottom support plate 6 screws 5 Remove the support plate with fin exchanger downwards 6 Carefully re install the replace ment heat exchanger and all further componen...

Page 12: ...he produced con densate in cooling operation The pump is a self priming rotary diaphragm pump The condensate is pumped out via a flexible PVC condensate hose with an internal diameter of 6 mm Safety i...

Page 13: ...red Unit dimensions Dimen sions PWL 101 103 HK PWL 201 203 HK PWL 301 303 HK A 985 mm 1084 mm 1178 mm B 632 mm 963 mm 1043 mm C 229 mm 229 mm 229 mm D 989 mm 1073 mm 1160 mm H 465 mm 485 mm 504 mm Con...

Page 14: ...8 34 11 6 36 16 4 41 14 2 42 20 6 9 30 6 1 31 11 0 37 10 0 39 14 2 45 12 3 44 70 50 C 0 12 0 16 10 7 18 19 5 28 17 8 31 25 4 37 22 0 40 5 10 8 20 9 7 21 17 6 30 16 1 33 23 0 39 19 9 42 10 9 7 24 8 6 2...

Page 15: ...0 24 54 4 5 23 55 7 8 20 67 7 0 19 69 10 5 17 77 9 3 16 79 32 40 5 9 25 55 5 3 25 56 9 2 21 67 8 3 20 69 12 3 18 77 10 8 16 79 8 14 C 24 60 2 5 21 71 2 3 21 72 4 1 19 80 3 7 18 81 5 9 17 86 5 3 16 88...

Page 16: ...7 5 33 15 5 34 22 5 38 19 8 40 20 8 4 28 7 5 29 15 1 35 13 4 37 19 4 40 17 1 42 70 50 C 0 14 5 13 13 0 14 26 6 25 23 7 27 34 5 34 30 4 36 5 12 9 17 11 6 18 24 1 28 21 4 30 31 2 36 27 4 38 10 11 4 21 1...

Page 17: ...74 12 3 17 76 32 40 6 4 27 53 5 8 26 54 12 3 22 65 11 2 21 67 16 1 19 74 14 4 18 76 8 14 C 24 60 2 2 22 68 2 0 22 69 5 6 19 79 5 1 19 80 7 2 18 85 6 5 17 86 26 50 2 8 23 59 2 5 23 60 5 9 20 73 5 2 20...

Page 18: ...9 30 14 9 33 29 2 37 16 5 43 20 10 9 28 8 2 29 17 8 33 12 8 36 25 2 39 14 3 45 70 50 C 0 18 8 12 14 3 15 31 0 21 22 3 26 44 8 32 25 6 41 5 16 9 16 12 7 19 27 8 24 20 0 29 40 5 34 23 2 43 10 14 9 20 1...

Page 19: ...8 15 81 32 40 8 3 27 52 6 5 26 55 13 0 23 63 10 0 22 68 29 1 19 73 12 7 16 81 8 14 C 24 60 3 0 22 68 2 3 21 70 8 4 17 81 3 6 19 79 9 4 18 84 6 0 16 89 26 50 3 7 23 58 2 8 23 61 8 5 18 74 4 4 20 70 9 9...

Page 20: ...a valuable contribution towards waste reduction and the conservation of raw materials Only dispose of packaging materi al at the facilities provided Disposal of old unit The production of our units is...

Page 21: ...2 speed 1110706 1110717 1110728 6 Top support plate 1110707 1110718 1110729 7 Bottom support plate 1110708 1110719 1110730 8 Side air grille 1110709 1110720 1110731 9 Bottom air segment 1110710 11107...

Page 22: ...With the external rotor motor the impeller with its drive motor is an optimal unit for applications in the field of heating and ventilation The axial flow fan is statically and dynamically balanced Th...

Page 23: ...750 920 750 Air capacity Bg 1 m3 h 2030 1685 3110 2580 4300 2650 Air capacity Bg 2 m3 h 1960 1610 2900 2400 4150 2400 Air capacity Bg 3 m3 h 1885 1530 2580 2350 3900 1710 Sound pressure level LpA 1m 1...

Page 24: ...t as advisers to our customers in air conditioning and heating technology SFlbCustomer Service Our equipment operates precisely and reliably However in the event of a fault REMKO customer service is q...

Reviews: