Starting
Make sure to charge a person with the operation of the
unit and with the supervision of the reservoirs and of the
bottle stock who has been instructed sufficiently regar-
ding the handlings concerned.
Make sure to draw the operators‘ attention to possible
dangers during the handling of liquid gas.
Connect pressure controller to the
gas bottle(s).
Attention – left-handed thread!
Open bottle valve(s).
When gas is taken out of several
gas bottles simultaneously, all the
valves have to be opened.
Press release button of the hose
security device (protection against
breakage)
after having opened
the
valve(s).
This has also to be done after each
replacement of bottles.
After the installation and connec-
tion of the units all the gas bearing
connections have to be checked
with soap solution, leakage detec-
ting spray etc. to make sure that
they are tight.
Do not use open flames!
1) Unscrew gas hose
Turn union nut clockwise
2) Fasten gas hose
Turn union nut anti-clockwise
This procedure also refers to all
further gas components, such as
pressure controller, hose security
device (protection against break-
age), etc.
Important Installation Hint
When installing or removing the gas hose make sure to
exert a counterpressure
on the
gas connection
nipple
of the unit using an open-end spanner SW 19
and observing the left-handed thread.
A constant unit connection pressure of 1.5 bar
(1500 mbar) must be ensured, also during con-
tinuous operation.
G
1.
2.
Install only in well ventilated rooms, not in rooms which people will be using for longer periods!
G
G
The setting can also be continuously adjusted when the
unit is operating.
4) Setting/Regulating the Heating Capacity
Set desired heating capacity by means of the
continuously adjustable “power regulation”.
Turn to the left:
i n c r e a s e d h e a t i n g c a p a c i t y
Turn to the right:
r e d u c e d h e a t i n g c a p a c i t y
Heating Operation
When connecting the unit to the mains
socket make sure to observe the right
polarity.
If the unit is switched off due to a fault
during the starting phase, the mains
plug has to be turned by 180°.
The unit runs in continuous operation.
Plug the supplied bridge plug (1) into
the thermostat socket (2).
1) Heating Without Room Thermostat
The unit operates fully automatically
and dependent from the temperature.
Remove bridge plug (1) and plug ther-
mostat plug (3) of the room thermo-
stat (accessories) into the thermostat
socket (2).
Preselect desired room temperature
on the room thermostat.
The selected temperature must be
higher than the actual room tempera-
ture.
2) Heating With Room Thermostat
Plug mains plug into a properly installed mains socket.
(230V/1 – 50Hz
with fault current breaker!)
Switch operating switch into “I”
position (= heating operation).
The ingoing air fan starts and the automatic burner
carries out the programme flow.
After approx. 15 seconds formation of the flames starts.
3) How to Start the Unit
G
2
1
2
3