Series                                                                                PGT 30                       PGT 60                       PGT 100 

 
Nominal heat output                           kW                              26                                55                                100 

Heating capacity                                 kW                           10 –  26                        25 –  55                         50 –  100 

Air output                                          m³/h                             800                            1.450                            3600 

Fuel/type of gas                                                                   l i q u i f i e d   g a s   C a t. I

3 B / P

 

Unit connecting gas-pressure             bar                             1,5                              1,5                               1,5 

Unit connecting value                       kg/h                         0,78 –  2,0                   1,95 –  4,27                      3,9 –  7,8

 

Electrical connection    1~                      V                             230                              230                               230 

Frequency                                            Hz                              50                                50                                 50 

Power consumption                            kW                            0,07                            0,11                            0,125 

Fuse-protection (required)                     A                              10                                10                                 10 

Kind of protection                                                                 IP 44                            IP 44                            IP 44 

Sound pressure level  L

pA 

1m

 

1)

     dB(A)                           56 –  69                        62 –  72                          74 –  82 

Weight (without accessories)              kg                              12                                20                                 47

 

Dimensions                           Length  mm                             450                              650                              1060 

                                                Width  mm                             260                              320                               435 

                                                 Hight  mm                             410                              510                               620 

 

1)  Noise measuring   DIN 45635 - 01- KL 3 

 

Technical Data  

Automatic burner relay:                             

Working voltage                                             230 V (-15% + 10%) 

                                                                       Frequency                                                      50 Hz (40 - 60 Hz) 

                                                                       Safety time                                                     5 seconds 

                                                                       Waiting time after interference cut-off           ca. 60 seconds 

                                                                       Allowable ambient temperature                     – 20° C ... + 60° C 

                                                                       Min. required ionisation current                     5 µA  

                                                                       Sensitivity (ionisation current)                        1 µA 

                                                                       Kind of protection                                           IP 44 

Any operation/handling which does not correspond to that indicated in these instructions is prohibited, 

otherwise we will not be responsible and the guarantee will become void. 

 

The orderer or the customer must have properly filled out the 

“guarantee certificate” 

which is enclosed 

with every REMKO automatic heater and must have returned it to REMKO GMBH & Co. KG within 

a timely acceptable period based on the sale and commissioning, to be entitled to possible 

guarantee claims regarding faulty material.

 

Technical Data:

 

Summary of Contents for PGT 100

Page 1: ...REMKO strong as a bear Propane Heater REMKO PGT 30 PGT 100 Edition GB L07 Operation Technology Spare Parts...

Page 2: ...Drawing PGT 100 12 List of spare parts PGT 100 13 Block diagrams 14 Technical data 15 G Always keep these operating instructions near or on the device G PGT 100 PGT 30 PGT 60 Mobile Propane Heaters O...

Page 3: ...ted only by those persons who have been instructed regarding the unit s operation and the handling of liquid gas When using the unit make sure always to obser ve the guiding principles of the countrie...

Page 4: ...constant unit connection pressure of 1 5 bar 1500 mbar must be ensured also during con tinuous operation G 1 2 Install only in well ventilated rooms not in rooms which people will be using for longer...

Page 5: ...you use a bottle battery consisting of at least 3 bottles All bottle valves must be open to ensure regular gas supply T connection high pressure hose 0 4 m pressure controller hose break protection g...

Page 6: ...ed set or repai red the gas supply has to be cut off and the mains plug has to be unplugged from the mains socket Setting and maintenance work is to be carried out only by authorized specialists Any o...

Page 7: ...rode incorrectly set Set according to instructions check porcelain insulation of electro des 9 Suction protective lattice of air supply fan is dirty Clean suction protective lattice 10 switching off b...

Page 8: ...8 We reserve the right to make modifications in dimensions and construction in the interests of technical progress Drawing PGT 30...

Page 9: ...37 clutch disc 38 gas burner 39 protection socket 40 retaining bracket not shown pressure controller with hose break protection 2 running metres gas hose 2 running metres HD gas hose for building sit...

Page 10: ...10 Drawing PGT 60 We reserve the right to make modifications in dimensions and construction in the interests of technical progress...

Page 11: ...t 1101197 30 solenoid valve 1101376 31 thermostat socket 1101018 32 shunt plug 1101019 33 gas connection nipple 3 8 lks 1101134 34 control knob cpl 1101192 36 traction relief 1101267 37 operating swit...

Page 12: ...12 Drawing PGT 100 We reserve the right to make modifications in dimensions and construction in the interests of technical progress...

Page 13: ...er 28 tube fitting M10 x 1 29 gas pipe R D Fig No Description 30 support bracket rear 31 operating switch 32 traction relief 33 connecting cable with plug 34 shunt plug 35 thermostat socket 36 control...

Page 14: ...de ZT ignition transformer Block Diagram PGT 100 HS auxiliary relay I ionisation electrode KL terminal strip M fan motor MV solenoid valve NK after cooling thermostat RS burner relay socket RT room th...

Page 15: ...uring DIN 45635 01 KL 3 Technical Data Automatic burner relay Working voltage 230 V 15 10 Frequency 50 Hz 40 60 Hz Safety time 5 seconds Waiting time after interference cut off ca 60 seconds Allowable...

Page 16: ...REMKO GmbH Co KG Klima und W rmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage Postfach 1827 Telefon 0 52 32 606 0 Telefax 0 52 32 606260...

Reviews: